B1835/58 Short in Curtain Shield Squib LH Circuit
Diagnostic trouble codes · Vehicles built Aug 2013 – Jul 2014
Also covers:
- B1836/58 Open in Curtain Shield Squib LH Circuit
- B1837/58 Short to GND in Curtain Shield Squib LH Circuit
- B1838/58 Short to B+ in Curtain Shield Squib LH Circuit
Versions by build date: Aug 2013 – Jul 2014 from Aug 2014
DESCRIPTION
The curtain shield squib LH circuit consists of the center airbag sensor and curtain shield airbag LH.The circuit instructs the SRS to deploy when deployment conditions are met.
These DTCs are stored when a malfunction is detected in the curtain shield squib LH circuit.
| DTC Code |
DTC Detection Condition |
Trouble Area |
| B1835/58 |
One of the following conditions is met:
|
|
| B1836/58 |
One of the following conditions is met:
|
|
| B1837/58 |
One of the following conditions is met:
|
|
| B1838/58 |
One of the following conditions is met:
|
|
WIRING DIAGRAM




INSPECTION PROCEDURE
- NOTICE:
- After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work (Click here).
- When disconnecting the cable from the negative (-) battery terminal while performing repairs, some systems need to be initialized after the cable is reconnected (Click here).
- After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work (Click here).
- HINT:
- To perform the simulation method, enter check mode (signal check) with the intelligent tester (Click here), and then wiggle each connector of the airbag system or drive the vehicle on various types of road (Click here).
| 1. CHECK VEHICLE TYPE |
Check vehicle type.
Result Result
Proceed to
for 3 Door
A
for 5 Door
B
|
|
||||
| B | |
| 2. CHECK CURTAIN SHIELD AIRBAG LH (CURTAIN SHIELD SQUIB LH) |
Turn the ignition switch off.

Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Disconnect the connectors from the curtain shield airbag LH.
Connect the black wire side of SST (resistance: 2.1 Ω) to connector C.
- CAUTION:
- Never connect the tester to the curtain shield airbag LH (curtain shield squib LH) for measurement, as this may lead to a serious injury due to airbag deployment.
- NOTICE:
- Do not forcibly insert SST into the terminals of the connector when connecting SST.
- Insert SST straight into the terminals of the connector.
- Do not forcibly insert SST into the terminals of the connector when connecting SST.
- SST
- 09843-18061
Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Turn the ignition switch to ON, and wait for at least 60 seconds.
Clear the DTCs (Click here).
Turn the ignition switch off.
Turn the ignition switch to ON, and wait for at least 60 seconds.
Check for DTCs (Click here).
- OK:
- DTC B1835, B1836, B1837 or B1838 is not output.
- HINT:
- Codes other than DTC B1835, B1836, B1837 and B1838 may be output at this time, but they are not related to this check.
Text in Illustration *1
Curtain Shield Squib LH
*2
Center Airbag Sensor
*3
Connector C
*4
SST
*a
Front view of wire harness connector
(to Curtain Shield Squib LH)
|
|
||||
| OK | ||
| ||
| 3. CHECK CONNECTOR |
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Disconnect SST from connector C.
Check that the floor wire connectors (on the curtain shield airbag LH side) are not damaged.

- OK:
- The lock button is not disengaged, and the claw of the lock is not deformed or damaged.
Text in Illustration *1
Curtain Shield Squib LH
*2
Center Airbag Sensor
|
|
||||
| OK | |
| 4. CHECK NO. 2 FLOOR WIRE (CURTAIN SHIELD AIRBAG LH - CENTER AIRBAG SENSOR) |
Disconnect the connectors from the center airbag sensor.

Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
Switch Condition
Specified Condition
R5-1 (ICL+) - Body ground
Ignition switch ON
Below 1 V
R5-2 (ICL-) - Body ground
Ignition switch ON
Below 1 V
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
R5-1 (ICL+) - R5-2 (ICL-)
Always
Below 1 Ω
Release the activation prevention mechanism built into connector B (Click here).
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
R5-1 (ICL+) - R5-2 (ICL-)
Always
1 MΩ or higher
R5-1 (ICL+) - Body ground
Always
1 MΩ or higher
R5-2 (ICL-) - Body ground
Always
1 MΩ or higher
| *1 |
Curtain Shield Squib LH |
| *2 |
No. 2 Floor Wire |
| *3 |
Center Airbag Sensor |
| *4 |
Connector C |
| *a |
Front view of wire harness connector (to Curtain Shield Squib LH) |
|
|
||||
| OK | |
| 5. CHECK CENTER AIRBAG SENSOR |
Connect the connectors to the curtain shield airbag LH and center airbag sensor.

Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Turn the ignition switch to ON, and wait for at least 60 seconds.
Clear the DTCs (Click here).
Turn the ignition switch off.
Turn the ignition switch to ON, and wait for at least 60 seconds.
Check for DTCs (Click here).
- OK:
- DTC B1835, B1836, B1837 or B1838 is not output.
- HINT:
- Codes other than DTC B1835, B1836, B1837 and B1838 may be output at this time, but they are not related to this check.
Text in Illustration *1
Curtain Shield Squib LH
*2
Center Airbag Sensor
|
|
||||
| OK | ||
| ||
| 6. CHECK CURTAIN SHIELD AIRBAG LH (CURTAIN SHIELD SQUIB LH) |
Turn the ignition switch off.

Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Disconnect the connectors from the curtain shield airbag LH.
Connect the white wire side of SST (resistance: 2.1 Ω) to connector C.
- CAUTION:
- Never connect the tester to the curtain shield airbag LH (curtain shield squib LH) for measurement, as this may lead to a serious injury due to airbag deployment.
- NOTICE:
- Do not forcibly insert SST into the terminals of the connector when connecting SST.
- Insert SST straight into the terminals of the connector.
- Do not forcibly insert SST into the terminals of the connector when connecting SST.
- SST
- 09843-18061
Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Turn the ignition switch to ON, and wait for at least 60 seconds.
Clear the DTCs (Click here).
Turn the ignition switch off.
Turn the ignition switch to ON, and wait for at least 60 seconds.
Check for DTCs (Click here).
- OK:
- DTC B1835, B1836, B1837 or B1838 is not output.
- HINT:
- Codes other than DTC B1835, B1836, B1837 and B1838 may be output at this time, but they are not related to this check.
Text in Illustration *1
Curtain Shield Squib LH
*2
Center Airbag Sensor
*3
Connector C
*4
SST
*a
Front view of wire harness connector
(to Curtain Shield Squib LH)
|
|
||||
| OK | ||
| ||
| 7. CHECK CONNECTOR |
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Disconnect SST from connector C.
Check that the floor wire connectors (on the curtain shield airbag LH side) are not damaged.

- OK:
- The lock button is not disengaged, and the claw of the lock is not deformed or damaged.
Text in Illustration *1
Curtain Shield Squib LH
*2
Center Airbag Sensor
|
|
||||
| OK | |
| 8. CHECK NO. 2 FLOOR WIRE (CURTAIN SHIELD AIRBAG LH - CENTER AIRBAG SENSOR) |
Disconnect the connectors from the center airbag sensor.

Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
Switch Condition
Specified Condition
R35-1 (ICL+) - Body ground
Ignition switch ON
Below 1 V
R35-2 (ICL-) - Body ground
Ignition switch ON
Below 1 V
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
R35-1 (ICL+) - R35-2 (ICL-)
Always
Below 1 Ω
Release the activation prevention mechanism built into connector B (Click here).
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
R35-1 (ICL+) - R35-2 (ICL-)
Always
1 MΩ or higher
R35-1 (ICL+) - Body ground
Always
1 MΩ or higher
R35-2 (ICL-) - Body ground
Always
1 MΩ or higher
| *1 |
Curtain Shield Squib LH |
| *2 |
No. 2 Floor Wire |
| *3 |
Center Airbag Sensor |
| *4 |
Connector C |
| *a |
Front view of wire harness connector (to Curtain Shield Squib LH) |
|
|
||||
| OK | |
| 9. CHECK CENTER AIRBAG SENSOR |
Connect the connectors to the curtain shield airbag LH and center airbag sensor.

Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Turn the ignition switch to ON, and wait for at least 60 seconds.
Clear the DTCs (Click here).
Turn the ignition switch off.
Turn the ignition switch to ON, and wait for at least 60 seconds.
Check for DTCs (Click here).
- OK:
- DTC B1835, B1836, B1837 or B1838 is not output.
- HINT:
- Codes other than DTC B1835, B1836, B1837 and B1838 may be output at this time, but they are not related to this check.
Text in Illustration *1
Curtain Shield Squib LH
*2
Center Airbag Sensor
|
|
||||
| OK | ||
| ||