Meter Illumination does not Dim at Night
Circuit diagnosis · Vehicles built Aug 2013 – Jul 2014
Versions by build date: Aug 2013 – Jul 2014 from Aug 2014
DESCRIPTION
If the dimmer switch is turned to TAIL, HEAD or AUTO, the main body ECU sends a TAIL relay signal, panel light illumination signal, panel relay signal, and TAIL cancel OFF signal to the combination meter. Then the meter dims.- HINT:
- TAIL cancel switch: When the headlights are illuminated and the TAIL cancel switch is turned ON, the meter does not dim.
WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. CHECK CAN COMMUNICATION SYSTEM |
Check if a CAN communication DTC is output.
for LHD with Entry and Start System (Click here).
for LHD without Entry and Start System (Click here).
for RHD with Entry and Start System (Click here).
for RHD without Entry and Start System (Click here).
Result Result
Proceed to
CAN communication system DTC is not output
A
CAN communication system DTC is output (for LHD with Entry and Start System)
B
CAN communication system DTC is output (for LHD without Entry and Start System)
C
CAN communication system DTC is output (for RHD with Entry and Start System)
D
CAN communication system DTC is output (for RHD without Entry and Start System)
E
|
|
||||
|
|
||||
|
|
||||
|
|
||||
| A | |
| 2. READ VALUE USING INTELLIGENT TESTER (LIGHT CONTROL RHEOSTAT) |
Operate the intelligent tester according to the display and select Data List (Click here).
Combination Meter Tester Display
Measurement Item/Range
Normal Condition
Diagnostic Note
Tail Cancel SW*
TAIL cancel switch condition/ON or OFF
ON: TAIL cancel switch ON
OFF: TAIL cancel switch OFF
-
Rheostat value
Light control rheostat switch input/Min.: 0, Max.: 100
Light control rheostat switch is fully turned left (0) → fully turned right (100)
Unit: %
- *: w/ TAIL Cancel Switch
- OK:
- Light brightness can be changed within specified range by manual operation.
- *: w/ TAIL Cancel Switch
|
|
||||
| OK | ||
| ||
| 3. INSPECT LIGHT CONTROL RHEOSTAT |
Inspect the light control rheostat. (w/o TAIL cancel switch)


Remove the light control rheostat (Click here).
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
for LHD Tester Connection
Switch Condition
Specified Condition
5 (T) - 1 (E)
Always
8 to 12 kΩ
7 (RV) - 1 (E)
Light control rheostat fully turned right → fully turned left
Below 100 Ω → 8 to 12 kΩ
for RHD Tester Connection
Switch Condition
Specified Condition
8 (T) - 4 (E)
Always
8 to 12 kΩ
6 (RV) - 4 (E)
Light control rheostat fully turned right → fully turned left
Below 100 Ω → 8 to 12 kΩ
Inspect the light control rheostat. (w/ TAIL cancel switch)


Remove the light control rheostat (Click here).
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
for LHD Tester Connection
Switch Condition
Specified Condition
5 (T) - 6 (TC)
TAIL cancel switch off → on
1 MΩ or higher → Below 1 Ω
5 (T) - 1 (E)
Always
8 to 12 kΩ
7 (RV) - 1 (E)
Light control rheostat fully turned right → fully turned left
Below 100 Ω → 8 to 12 kΩ
for RHD Tester Connection
Switch Condition
Specified Condition
8 (T) - 7 (TC)
TAIL cancel switch off → on
1 MΩ or higher → Below 1 Ω
8 (T) - 4 (E)
Always
8 to 12 kΩ
6 (RV) - 4 (E)
Light control rheostat fully turned right → fully turned left
Below 100 Ω → 8 to 12 kΩ
|
|
||||
| OK | |
| 4. CHECK HARNESS AND CONNECTOR (COMBINATION METER - LIGHT CONTROL RHEOSTAT) |
Disconnect the G6 meter connector.
Disconnect the G16 rheostat connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
for LHD Tester Connection
Condition
Specified Condition
G6-6 (SW1) - G16-5 (T)
Always
Below 1 Ω
G6-7 (SW2) - G16-7 (RV)
G6-22 (SW3) - G16-1 (E)
G6-10 (TC) - G16-6 (TC)*
for RHD Tester Connection
Condition
Specified Condition
G6-6 (SW1) - G16-8 (T)
Always
Below 1 Ω
G6-7 (SW2) - G16-6 (RV)
G6-22 (SW3) - G16-4 (E)
G6-10 (TC) - G16-7 (TC)*
- *: w/ TAIL Cancel Switch
|
|
||||
| OK | ||
| ||