2013-2015 Land Cruiser Prado · Service Manual Vehicle Interior

Meter Illumination does not Dim at Night

Circuit diagnosis · Vehicles built from Aug 2014

Versions by build date: Aug 2013 – Jul 2014 from Aug 2014

DESCRIPTION

If the dimmer switch is turned to TAIL, HEAD or AUTO, the main body ECU sends a TAIL relay signal, panel light illumination signal, panel relay signal, and TAIL cancel OFF signal to the combination meter. Then the meter dims.

HINT:
TAIL cancel switch: When the headlights are illuminated and the TAIL cancel switch is turned ON, the meter does not dim.


WIRING DIAGRAM

E284896E01

INSPECTION PROCEDURE


1. CHECK CAN COMMUNICATION SYSTEM
  1. Check if a CAN communication DTC is output.

    1. for LHD with Entry and Start System (Click here).

    2. for LHD without Entry and Start System (Click here).

    3. for RHD with Entry and Start System (Click here).

    4. for RHD without Entry and Start System (Click here).

      Result 
      Result
      Proceed to
      CAN communication system DTC is not output
      A
      CAN communication system DTC is output (for LHD with Entry and Start System)
      B
      CAN communication system DTC is output (for LHD without Entry and Start System)
      C
      CAN communication system DTC is output (for RHD with Entry and Start System)
      D
      CAN communication system DTC is output (for RHD without Entry and Start System)
      E



B
GO TO CAN COMMUNICATION SYSTEM (Click here)

C
GO TO CAN COMMUNICATION SYSTEM (Click here)

D
GO TO CAN COMMUNICATION SYSTEM (Click here)

E
GO TO CAN COMMUNICATION SYSTEM (Click here)
A


2. READ VALUE USING INTELLIGENT TESTER (LIGHT CONTROL RHEOSTAT)
  1. Operate the intelligent tester according to the display and select Data List (Click here).

    Combination Meter 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Tail Cancel SW*
    TAIL cancel switch condition/ON or OFF
    ON: TAIL cancel switch ON
    OFF: TAIL cancel switch OFF
    -
    Rheostat value
    Light control rheostat switch input/Min.: 0, Max.: 100
    Light control rheostat switch is fully turned left (0) → fully turned right (100)
    Unit: %
    1. *: w/ TAIL Cancel Switch

    OK:
    Light brightness can be changed within specified range by manual operation.



NG
Go to step 3
OK

REPLACE COMBINATION METER ASSEMBLY (Click here)

3. INSPECT LIGHT CONTROL RHEOSTAT

  1. Inspect the light control rheostat. (w/o TAIL cancel switch)E284897E01

    1. Remove the light control rheostat (Click here).

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      for LHD 
      Tester Connection
      Switch Condition
      Specified Condition
      5 (T) - 1 (E)
      Always
      8 to 12 kΩ
      7 (RV) - 1 (E)
      Light control rheostat fully turned right → fully turned left
      Below 100 Ω → 8 to 12 kΩ
      for RHD 
      Tester Connection
      Switch Condition
      Specified Condition
      8 (T) - 4 (E)
      Always
      8 to 12 kΩ
      6 (RV) - 4 (E)
      Light control rheostat fully turned right → fully turned left
      Below 100 Ω → 8 to 12 kΩ

  1. Inspect the light control rheostat. (w/ TAIL cancel switch)E284898E01

    1. Remove the light control rheostat (Click here).

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      for LHD 
      Tester Connection
      Switch Condition
      Specified Condition
      5 (T) - 6 (TC)
      TAIL cancel switch off → on
      1 MΩ or higher → Below 1 Ω
      5 (T) - 1 (E)
      Always
      8 to 12 kΩ
      7 (RV) - 1 (E)
      Light control rheostat fully turned right → fully turned left
      Below 100 Ω → 8 to 12 kΩ
      for RHD 
      Tester Connection
      Switch Condition
      Specified Condition
      8 (T) - 7 (TC)
      TAIL cancel switch off → on
      1 MΩ or higher → Below 1 Ω
      8 (T) - 4 (E)
      Always
      8 to 12 kΩ
      6 (RV) - 4 (E)
      Light control rheostat fully turned right → fully turned left
      Below 100 Ω → 8 to 12 kΩ



NG
REPLACE LIGHT CONTROL RHEOSTAT (Click here)
OK


4. CHECK HARNESS AND CONNECTOR (COMBINATION METER - LIGHT CONTROL RHEOSTAT)
  1. Disconnect the G6 meter connector.

  1. Disconnect the G16 rheostat connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    for LHD 
    Tester Connection
    Condition
    Specified Condition
    G6-6 (SW1) - G16-5 (T)
    Always
    Below 1 Ω
    G6-7 (SW2) - G16-7 (RV)
    G6-22 (SW3) - G16-1 (E)
    G6-10 (TC) - G16-6 (TC)*
    for RHD 
    Tester Connection
    Condition
    Specified Condition
    G6-6 (SW1) - G16-8 (T)
    Always
    Below 1 Ω
    G6-7 (SW2) - G16-6 (RV)
    G6-22 (SW3) - G16-4 (E)
    G6-10 (TC) - G16-7 (TC)*

    1. *: w/ TAIL Cancel Switch



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE COMBINATION METER ASSEMBLY (Click here)


← Meter Illumination does not Dim at Night (Aug 2013 – Jul 2014)Speed Signal Circuit (Aug 2013 – Jul 2014) →