Home › Engine / Hybrid System › 1GR-FE ENGINE CONTROL › SFI SYSTEM
Fuel Pump Control Circuit
Circuit diagnosis · Vehicles built Aug 2013 – Jul 2014
Versions by build date: Aug 2013 – Jul 2014 from Aug 2014
DESCRIPTION
The fuel pump circuit consists of the ECM, fuel pump and fuel pump ECU (which operates the fuel pump). Based on the engine output, the ECM determines the fuel pump speed. The speed is then converted to a duty signal and sent to the fuel pump ECU. Based on the signal sent from the ECM, the fuel pump ECU adjusts the fuel pump operation speed among 3 settings. WIRING DIAGRAM
Refer to DTC P0230 (Click here ). INSPECTION PROCEDURE
This troubleshooting procedure is based on the premise that the engine is started. If the engine is not started, proceed to Problem Symptoms Table (Click here ).
1. PERFORM ACTIVE TEST USING INTELLIGENT TESTER (FUEL PUMP)
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON and turn the tester on.
Enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Fuel Pump / Speed.
Check whether operating sounds can be heard while operating the relay using the tester.
OK:
Operating sounds can be heard from relay.
NG
OK
2. CHECK HARNESS AND CONNECTOR (FUEL PUMP ECU - ECM, BODY GROUND)
Disconnect the fuel pump ECU connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance (Check for Open):
Tester Connection
Condition
Specified Condition
S8-1 (FPC) - G55-3 (FPC)
Always
Below 1 Ω
S8-2 (DI) - G56-26 (DI)
Always
Below 1 Ω
S8-3 (E) - Body ground
Always
Below 1 Ω
Standard Resistance (Check for Short):
Tester Connection
Condition
Specified Condition
S9-2 (FP-) - Body ground
Always
10 kΩ or higher
S8-1 (FPC) or G55-3 (FPC) - Body ground
Always
10 kΩ or higher
S8-2 (DI) or G56-26 (DI) - Body ground
Always
10 kΩ or higher
Reconnect the fuel pump ECU connector.
Reconnect the ECM connector.
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK
3. REPLACE FUEL PUMP ECU
Replace the fuel pump ECU (Click here ).
NEXT
4. CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED
Check the fuel pump operation.
OK:
Malfunction has been repaired successfully.
NG
OK
5. INSPECT CIRCUIT OPENING RELAY (C/OPN)
Inspect the circuit opening relay (C/OPN) (Click here ).
NG
REPLACE CIRCUIT OPENING RELAY (C/OPN)
OK
6. INSPECT CIRCUIT OPENING RELAY (C/OPN) (POWER SOURCE VOLTAGE)
Remove the circuit opening relay (C/OPN) from the engine room relay block.
Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection
Switch Condition
Specified Condition
C/OPN relay terminal 2 - Body ground
Ignition switch ON
11 to 14 V
C/OPN relay terminal 5 - Body ground
Ignition switch ON
11 to 14 V
Text in Illustration
*1
Engine Room Relay Block
*2
Circuit Opening Relay (C/OPN)
Reinstall the circuit opening relay (C/OPN).
NG
OK
7. CHECK HARNESS AND CONNECTOR (CIRCUIT OPENING RELAY (C/OPN) - ECU, FUEL PUMP ECU)
Remove the circuit opening relay (C/OPN) from the engine room relay block.
Disconnect the fuel pump ECU connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance (Check for Open):
Tester Connection
Condition
Specified Condition
C/OPN relay terminal 1 - G56-8(FC)
Always
Below 1 Ω
C/OPN relay terminal 3 - S8-4 (+B)
Always
Below 1 Ω
Standard Resistance (Check for Short):
Tester Connection
Condition
Specified Condition
C/OPN relay terminal 1 or G56-8 (FC) - Body ground
Always
10 kΩ or higher
C/OPN relay terminal 3 or S8-4 (+B) - Body ground
Always
10 kΩ or higher
Reinstall the circuit opening relay (C/OPN).
Reconnect the fuel pump ECU connector.
Reconnect the ECM connector.
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK
8. CHECK HARNESS AND CONNECTOR (FUEL PUMP - FUEL PUMP ECU)
Disconnect the fuel sender gauge connector.
Disconnect the fuel pump ECU connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance (Check for Open):
Tester Connection
Condition
Specified Condition
S5-4 (B2) - S9-1 (FP)
Always
Below 1 Ω
S5-5 (E2) - S9-2 (FP-)
Always
Below 1 Ω
Standard Resistance (Check for Short):
Tester Connection
Condition
Specified Condition
S5-4 (B2) or S9-1 (FP) - Body ground
Always
10 kΩ or higher
S5-5 (E2) or S9-2 (FP-) - Body ground
Always
10 kΩ or higher
Reconnect the fuel sender gauge connector.
Reconnect the fuel pump ECU connector.
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK
9. INSPECT FUEL PUMP
Inspect the fuel pump (for Single Tank Type) (Click here ).
Inspect the fuel pump (for Double Tank Type) (Click here ).
Result
Test Result
Proceed to
OK
A
NG (for Single Tank Type)
B
NG (for Double Tank Type)
C
B
C
A
10. CHECK HARNESS AND CONNECTOR (FUEL PUMP ECU - ECM, BODY GROUND)
Disconnect the fuel pump ECU connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance (Check for Open):
Tester Connection
Condition
Specified Condition
S8-1 (FPC) - G55-3 (FPC)
Always
Below 1 Ω
S8-2 (DI) - G56-26 (DI)
Always
Below 1 Ω
S8-3 (E) - Body ground
Always
Below 1 Ω
Standard Resistance (Check for Short):
Tester Connection
Condition
Specified Condition
S8-1 (FPC) or G55-3 (FPC) - Body ground
Always
10 kΩ or higher
S8-2 (DI) or G56-26 (DI) - Body ground
Always
10 kΩ or higher
Reconnect the fuel pump ECU connector.
Reconnect the ECM connector.
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK
11. REPLACE FUEL PUMP ECU
Replace the fuel pump ECU (Click here ).
NEXT
12. CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED
Check the fuel pump operation.
OK:
Malfunction has been repaired successfully.
NG
OK
13. CHECK HARNESS AND CONNECTOR (CIRCUIT OPENING RELAY (C/OPN) - IGN FUSE, NO. 1 INTEGRATION RELAY)
Remove the circuit opening relay (C/OPN) from the engine room relay block.
Remove the No. 1 integration relay from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
Standard Resistance (Check for Open):
Tester Connection
Condition
Specified Condition
C/OPN relay terminal 2 - 1A-5
Always
Below 1 Ω
C/OPN relay terminal 5 - 1B-4
Always
Below 1 Ω
Standard Resistance (Check for Short):
Tester Connection
Condition
Specified Condition
C/OPN relay terminal 2 or 1A-5 - Body ground
Always
10 kΩ or more
C/OPN relay terminal 5 or 1B-4 - Body ground
Always
10 kΩ or more
Reinstall the circuit opening relay (C/OPN).
Reinstall the No. 1 integration relay.
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK