Home › Vehicle Interior › THEFT DETERRENT / KEYLESS ENTRY › THEFT DETERRENT SYSTEM
Security Horn Circuit
Circuit diagnosis · Vehicles built from Aug 2014
Versions by build date: Aug 2013 – Jul 2014 from Aug 2014
DESCRIPTION
When the theft deterrent system is in the alarm sounding state, the main body ECU outputs a signal repeatedly at 0.4 second intervals, causing the security horn assembly to sound. WIRING DIAGRAM
INSPECTION PROCEDURE
NOTICE:
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
1. PERFORM ACTIVE TEST USING INTELLIGENT TESTER (SECURITY HORN)
Operate the intelligent tester according to the steps on the display and select Active Test (Click here ).
Main Body
Tester Display
Test Part
Control Range
Diagnostic Note
Security Horn
Security horn
ON/OFF
-
OK:
Security horn operates normally.
NG
OK
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here )
2. INSPECT S-HORN RELAY
Remove the S-HORN relay from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
Condition
Specified Condition
3 - 5
Battery voltage is not applied to terminals 1 and 2
10 kΩ or higher
3 - 5
Battery voltage is applied to terminals 1 and 2
Below 1 Ω
NG
OK
3. INSPECT SECURITY HORN ASSEMBLY
Remove the security horn (Click here ).
Apply battery voltage to the horn connector and check the operation of the horn.
OK:
Measurement Condition
Specified Condition
Battery positive (+) → Terminal 1 Battery negative (-) → Horn bracket
Horn sounds
NG
OK
4. CHECK HARNESS AND CONNECTOR (ENGINE ROOM RELAY BLOCK - MAIN BODY ECU AND SECURITY HORN)
Remove the S-HORN relay from the engine room relay block.
Remove the main body ECU (Click here ).
Disconnect the A26 horn connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
Condition
Specified Condition
Relay block S-HORN relay terminal 1 - A-17 (SH)
Always
Below 1 Ω
Relay block S-HORN relay terminal 3 - A26-1
Always
Below 1 Ω
A-17 (SH) - Body ground
Always
10 kΩ or higher
A26-1 - Body ground
Always
10 kΩ or higher
Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection
Condition
Specified Condition
Relay block S-HORN relay terminal 2 - Body ground
Always
11 to 14 V
Relay block S-HORN relay terminal 5 - Body ground
Always
11 to 14 V
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK
REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU) (Click here )