VSC OFF Indicator Light does not Come ON
Circuit diagnosis · Vehicles built from Aug 2014
Versions by build date: Aug 2013 – Jul 2014 from Aug 2014
DESCRIPTION
Refer to VSC OFF Indicator Light Remains ON (Click here).WIRING DIAGRAM
Refer to VSC OFF Indicator Light Remains ON (Click here).INSPECTION PROCEDURE
- NOTICE:
- When replacing the master cylinder solenoid, perform calibration (Click here).
| 1. CHECK CAN COMMUNICATION LINE |
Turn the ignition switch off.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Select CAN Bus Check from the System Selection Menu screen and follow the prompts on the screen to inspect the CAN bus (for LHD: Click here, for RHD: Click here).
- OK:
- CAN Bus Check indicates no malfunctions in CAN communication.
Result Result
Proceed to
OK
A
NG (for LHD)
B
NG (for RHD)
C
|
|
||||
|
|
||||
| A | |
| 2. READ VALUE USING INTELLIGENT TESTER (TRC/VSC OFF MODE) |
Turn the ignition switch off.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Enter the following menus: Chassis / ABS/VSC/TRC / Data List.
ABS/VSC/TRC Tester Display
Measurement Item/Range
Normal Condition
Diagnostic Note
TRC/VSC Off Mode
TRC/VSC off mode/ Normal, TRC OFF or VSC OFF
Normal: Normal mode
TRC OFF: TRC OFF mode
VSC OFF: VSC OFF mode
-
Check that the mode display changes according to VSC OFF switch operation.
- OK:
- Display changes according to switch operation.
|
|
||||
| OK | ||
| ||
| 3. CHECK HARNESS AND CONNECTOR (SKID CONTROL ECU - VSC OFF SWITCH) |
Disconnect the A7 skid control ECU (master cylinder solenoid) connector.
Disconnect the G9 VSC OFF switch connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
A7-9 (CSW) - G9-6
Always
Below 1 Ω
A7-9 (CSW) - Body ground
Always
10 kΩ or higher
G9-3 - Body ground
Always
Below 1 Ω
|
|
||||
| OK | |
| 4. INSPECT VSC OFF SWITCH |
Remove the VSC OFF switch (Click here).
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
6 - 3
Switch is not pushed
10 kΩ or higher
Switch is pushed
Below 1 Ω
Text in Illustration *a
Component without harness connected
(VSC OFF Switch)
Result Result
Proceed to
NG
A
OK (for LHD)
B
OK (for RHD)
C
|
|
||||
|
|
||||
| A | ||
| ||