P0416 Secondary Air Injection System Switching Valve "B" Circuit Open
Diagnostic trouble codes · Vehicles built from Aug 2014
Also covers:
- P0417 Secondary Air Injection System Switching Valve "B" Circuit Shorted
Versions by build date: Aug 2013 – Jul 2014 from Aug 2014
DESCRIPTION
The ECM operates the air injection VSV relay (AI-VSV) which causes the No. 2 emission control valve set to operate.| DTC No. |
DTC Detection Condition |
Trouble Area |
| P0416 |
Open or short in the air injection VSV relay (AI-VSV) circuit for 3 seconds (1 trip detection logic). |
|
| P0417 |
Open or short in the air injection VSV relay (AI-VSV) circuit for 3 seconds (1 trip detection logic). |
|
WIRING DIAGRAM


INSPECTION PROCEDURE
- NOTICE:
- Inspect the fuses of circuits related to this system before performing the following inspection procedure.
- HINT:
- Read freeze frame data using the intelligent tester. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data from the time the malfunction occurred.
| 1. INSPECT AIR INJECTION VSV RELAY (AI-VSV) |
Inspect the air injection VSV relay (AI-VSV) (Click here).
|
|
||||
| OK | |
| 2. CHECK AIR INJECTION VSV RELAY (AI-VSV) (POWER SOURCE) |
Remove the air injection VSV relay (AI-VSV).
Measure the voltage according to the value(s) in the table below.

- Standard Voltage:
Tester Connection
Condition
Specified Condition
Air injection VSV relay (AI-VSV) terminal 1 - Body ground
Ignition switch ON
11 to 14 V
Air injection VSV relay (AI-VSV) terminal 5 - Body ground
Ignition switch ON
11 to 14 V
Text in Illustration *1
Engine Room Relay Block
*2
Air Injection VSV Relay (AI-VSV)
Reinstall the air injection VSV relay (AI-VSV).
|
|
||||
| OK | |
| 3. CHECK HARNESS AND CONNECTOR (ECM - AIR INJECTION VSV RELAY (AI-VSV)) |
Remove the air injection VSV relay (AI-VSV).
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance (Check for Open):
Tester Connection
Condition
Specified Condition
Air injection VSV relay (AI-VSV) terminal 2 - C36-21 (AIR1)
Always
Below 1 Ω
- Standard Resistance (Check for Short):
Tester Connection
Condition
Specified Condition
Air injection VSV relay (AI-VSV) terminal 2 or C36-21 (AIR1) - Body ground
Always
10 kΩ or higher
Reinstall the air injection VSV relay (AI-VSV).
Reconnect the ECM connector.
|
|
||||
| OK | ||
| ||