INSPECTION
Inspection · Vehicles built from Aug 2013
| INSPECT FRONT POWER SEAT SWITCH LH (for LHD) |
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
- Slide Switch:
Tester Connection
Switch Condition
Specified Condition
5 (SLDF) - 8 (B)
5 (SLDF) - 7 (B1)
Front
Below 1 Ω
2 (SLDR) - 11 (E)
2 (SLDR) - 12 (E1)
5 (SLDF) - 11 (E)
5 (SLDF) - 12 (E1)
Off
2 (SLDR) - 11 (E)
2 (SLDR) - 12 (E1)
5 (SLDF) - 11 (E)
5 (SLDF) - 12 (E1)
Rear
2 (SLDR) - 8 (B)
2 (SLDR) - 7 (B1)
- Front Vertical Switch:
Tester Connection
Switch Condition
Specified Condition
1 (FUP) - 8 (B)
1 (FUP) - 7 (B1)
Up
Below 1 Ω
6 (FDWN) - 11 (E)
6 (FDWN) - 12 (E1)
1 (FUP) - 11 (E)
1 (FUP) - 12 (E1)
Off
6 (FDWN) - 11 (E)
6 (FDWN) - 12 (E1)
1 (FUP) - 11 (E)
1 (FUP) - 12 (E1)
Down
6 (FDWN) - 8 (B)
6 (FDWN) - 7 (B1)
- Lifter Switch:
Tester Connection
Switch Condition
Specified Condition
3 (LUP) - 8 (B)
3 (LUP) - 7 (B1)
Up
Below 1 Ω
4 (LDWN) - 11 (E)
4 (LDWN) - 12 (E1)
3 (LUP) - 11 (E)
3 (LUP) - 12 (E1)
Off
4 (LDWN) - 11 (E)
4 (LDWN) - 12 (E1)
3 (LUP) - 11 (E)
3 (LUP) - 12 (E1)
Down
4 (LDWN) - 8 (B)
4 (LDWN) - 7 (B1)
- Reclining Switch:
Tester Connection
Switch Condition
Specified Condition
10 (RCLF) - 8 (B)
10 (RCLF) - 7 (B1)
Front
Below 1 Ω
9 (RCLR) - 11 (E)
9 (RCLR) - 12 (E1)
10 (RCLF) - 11 (E)
10 (RCLF) - 12 (E1)
Off
9 (RCLR) - 11 (E)
9 (RCLR) - 12 (E1)
10 (RCLF) - 11 (E)
10 (RCLF) - 12 (E1)
Rear
9 (RCLR) - 8 (B)
9 (RCLR) - 7 (B1)
Text in Illustration *1
Front Vertical Switch
*2
Slide Switch
*3
Lifter Switch
*4
Reclining Switch
*a
Component without harness connected
(Front Power Seat Switch)
| INSPECT FRONT POWER SEAT SWITCH RH (for LHD) |
for 4 Way Seat Type:

Measure the resistance according to the value(s) in the table below.- Standard Resistance:
- Slide Switch:
Tester Connection
Switch Condition
Specified Condition
2 (SLDF) - 13 (B)
Front
Below 1 Ω
5 (SLDR) - 10 (E)
2 (SLDF) - 10 (E)
Off
5 (SLDR) - 10 (E)
2 (SLDF) - 10 (E)
Rear
5 (SLDR) - 13 (B)
- Reclining Switch:
Tester Connection
Switch Condition
Specified Condition
11 (RCLF) - 13 (B)
Front
Below 1 Ω
12 (RCLR) - 10 (E)
11 (RCLF) - 10 (E)
Off
12 (RCLR) - 10 (E)
11 (RCLF) - 10 (E)
Rear
12 (RCLR) - 13 (B)
Text in Illustration *1
Slide Switch
*2
Reclining Switch
*a
Component without harness connected
(Front Power Seat Switch)
for 8 Way Seat Type:

Measure the resistance according to the value(s) in the table below.- Standard Resistance:
- Slide Switch:
Tester Connection
Switch Condition
Specified Condition
2 (SLDF) - 13 (B)
2 (SLDF) - 14 (B1)
Front
Below 1 Ω
5 (SLDR) - 10 (E)
5 (SLDR) - 9 (E1)
2 (SLDF) - 10 (E)
2 (SLDF) - 9 (E1)
Off
5 (SLDR) - 10 (E)
5 (SLDR) - 9 (E1)
2 (SLDF) - 10 (E)
2 (SLDF) - 9 (E1)
Rear
5 (SLDR) - 13 (B)
5 (SLDR) - 14 (B1)
- Front Vertical Switch:
Tester Connection
Switch Condition
Specified Condition
6 (FUP) - 13 (B)
6 (FUP) - 14 (B1)
Up
Below 1 Ω
1 (FDWN) - 10 (E)
1 (FDWN) - 9 (E1)
6 (FUP) - 10 (E)
6 (FUP) - 9 (E1)
Off
1 (FDWN) - 10 (E)
1 (FDWN) - 9 (E1)
6 (FUP) - 10 (E)
6 (FUP) - 9 (E1)
Down
1 (FDWN) - 13 (B)
1 (FDWN) - 14 (B1)
- Lifter Switch:
Tester Connection
Switch Condition
Specified Condition
4 (LUP) - 13 (B)
4 (LUP) - 14 (B1)
Up
Below 1 Ω
3 (LDWN) - 10 (E)
3 (LDWN) - 9 (E1)
4 (LUP) - 10 (E)
4 (LUP) - 9 (E1)
Off
3 (LDWN) - 10 (E)
3 (LDWN) - 9 (E1)
4 (LUP) - 10 (E)
4 (LUP) - 9 (E1)
Down
3 (LDWN) - 13 (B)
3 (LDWN) - 14 (B1)
- Reclining Switch:
Tester Connection
Switch Condition
Specified Condition
11 (RCLF) - 13 (B)
11 (RCLF) - 14 (B1)
Front
Below 1 Ω
12 (RCLR) - 10 (E)
12 (RCLR) - 9 (E1)
11 (RCLF) - 10 (E)
11 (RCLF) - 9 (E1)
Off
12 (RCLR) - 10 (E)
12 (RCLR) - 9 (E1)
11 (RCLF) - 10 (E)
11 (RCLF) - 9 (E1)
Rear
12 (RCLR) - 13 (B)
12 (RCLR) - 14 (B1)
Text in Illustration *1
Front Vertical Switch
*2
Slide Switch
*3
Lifter Switch
*4
Reclining Switch
*a
Component without harness connected
(Front Power Seat Switch)
| INSPECT FRONT POWER SEAT SWITCH RH (for RHD) |
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
- Slide Switch:
Tester Connection
Switch Condition
Specified Condition
2 (SLDF) - 13 (B)
2 (SLDF) - 14 (B1)
Front
Below 1 Ω
5 (SLDR) - 10 (E)
5 (SLDR) - 9 (E1)
2 (SLDF) - 10 (E)
2 (SLDF) - 9 (E1)
Off
5 (SLDR) - 10 (E)
5 (SLDR) - 9 (E1)
2 (SLDF) - 10 (E)
2 (SLDF) - 9 (E1)
Rear
5 (SLDR) - 13 (B)
5 (SLDR) - 14 (B1)
- Front Vertical Switch:
Tester Connection
Switch Condition
Specified Condition
6 (FUP) - 13 (B)
6 (FUP) - 14 (B1)
Up
Below 1 Ω
1 (FDWN) - 10 (E)
1 (FDWN) - 9 (E1)
6 (FUP) - 10 (E)
6 (FUP) - 9 (E1)
Off
1 (FDWN) - 10 (E)
1 (FDWN) - 9 (E1)
6 (FUP) - 10 (E)
6 (FUP) - 9 (E1)
Down
1 (FDWN) - 13 (B)
1 (FDWN) - 14 (B1)
- Lifter Switch:
Tester Connection
Switch Condition
Specified Condition
4 (LUP) - 13 (B)
4 (LUP) - 14 (B1)
Up
Below 1 Ω
3 (LDWN) - 10 (E)
3 (LDWN) - 9 (E1)
4 (LUP) - 10 (E)
4 (LUP) - 9 (E1)
Off
3 (LDWN) - 10 (E)
3 (LDWN) - 9 (E1)
4 (LUP) - 10 (E)
4 (LUP) - 9 (E1)
Down
3 (LDWN) - 13 (B)
3 (LDWN) - 14 (B1)
- Reclining Switch:
Tester Connection
Switch Condition
Specified Condition
11 (RCLF) - 13 (B)
11 (RCLF) - 14 (B1)
Front
Below 1 Ω
12 (RCLR) - 10 (E)
12 (RCLR) - 9 (E1)
11 (RCLF) - 10 (E)
11 (RCLF) - 9 (E1)
Off
12 (RCLR) - 10 (E)
12 (RCLR) - 9 (E1)
11 (RCLF) - 10 (E)
11 (RCLF) - 9 (E1)
Rear
12 (RCLR) - 13 (B)
12 (RCLR) - 14 (B1)
Text in Illustration *1
Front Vertical Switch
*2
Slide Switch
*3
Lifter Switch
*4
Reclining Switch
*a
Component without harness connected
(Front Power Seat Switch)
| INSPECT FRONT POWER SEAT SWITCH LH (for RHD) |
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
- Slide Switch:
Tester Connection
Switch Condition
Specified Condition
5 (SLDF) - 8 (B)
Front
Below 1 Ω
2 (SLDR) - 11 (E)
5 (SLDF) - 11 (E)
Off
2 (SLDR) - 11 (E)
5 (SLDF) - 11 (E)
Rear
2 (SLDR) - 8 (B)
- Reclining Switch:
Tester Connection
Switch Condition
Specified Condition
10 (RCLF) - 8 (B)
Front
Below 1 Ω
9 (RCLR) - 11 (E)
10 (RCLF) - 11 (E)
Off
9 (RCLR) - 11 (E)
10 (RCLF) - 11 (E)
Rear
9 (RCLR) - 8 (B)
Text in Illustration *1
Slide Switch
*2
Reclining Switch
*a
Component without harness connected
(Front Power Seat Switch)