The intake mass air flow meter assembly consists of a platinum hot wire, temperature sensor and control circuit installed in a plastic housing. The temperature sensor (located in the intake air by-pass of the housing) detects the intake air temperature.
There is little variation in the output from the intake mass air flow meter assembly, as it is hardly affected by the resistance of the wire harness.
The internal circuit of the intake mass air flow meter assembly contains a hot wire and cold wire. A voltage is output through a bridge circuit (refer to the illustration) indicating the cooling of the hot wire according to the intake air amount. This voltage is then converted into a periodic signal by the periodic signal conversion circuit and output to the ECM. The frequency varies between approximately 1945 and 8500 Hz depending on the air flow rate. The ECM calculates the mass air flow rate based on this frequency.
| DTC Detection Drive Pattern | DTC Detection Condition | Trouble Area |
|---|---|---|
| 3 seconds after engine is started | Mass air flow meter signal frequency is less than 85 Hz with the engine speed at 5000 rpm or less for 3 seconds (1 trip detection logic). | ·
Open or short in mass air flow meter circuit ·
Mass air flow meter ·
ECM |
| DTC Detection Drive Pattern | DTC Detection Condition | Trouble Area |
|---|---|---|
| 3 seconds after engine is started | Mass air flow meter signal frequency is more than 9800 Hz with the engine speed at 5000 rpm or less for 3 seconds (1 trip detection logic). | ·
Open or short in Mass air flow meter circuit ·
Mass air flow meter ·
ECM |
| DTC No. | Data List |
|---|---|
| P0102 | MAF |
| P0103 |
If DTC P0102 is stored, the following symptoms may appear (as the ECM mistakenly determines that there is less air than the actual intake air amount, EGR is decreased according to the target EGR):
Combustion noise worsens
If DTC P0103 is stored, the following symptoms may appear (as the ECM mistakenly determines that there is more air than the actual intake air amount, EGR is increased according to the target EGR):
Misfire
White smoke
Black smoke
Inspect the fuses of circuits related to this system before performing the following inspection procedure.
After replacing the ECM, the new ECM needs registration (See page Engine / Hybrid System>1KD-FTV (ENGINE CONTROL)>ECD SYSTEM>REGISTRATION) and initialization (See page Engine / Hybrid System>1KD-FTV (ENGINE CONTROL)>ECD SYSTEM>INITIALIZATION).
Read freeze frame data using the intelligent tester. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, and other data from the time the malfunction occurred.
Disconnect the mass air flow meter connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| C33-3 (+B) - Body ground | Ignition switch ON | 11 to 14 V |
| *a | Front view of wire harness connector
(to mass air flow meter) |
Reconnect the mass air flow meter connector.
OK
NG
Disconnect the mass air flow meter connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C33-5 (VG) - C90-17 (VG) | Always | Below 1 Ω |
| C33-4 (E2G) - C90-18 (EVG) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C33-5 (VG) or C90-17 (VG) - Body ground | Always | 10 kΩ or higher |
Reconnect the mass air flow meter connector.
Reconnect the ECM connector.
OK
NG
Disconnect the mass air flow meter connector.
Remove the No. 1 integration relay from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C33-3 (+B) - 1B-4 | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C33-3 (+B) or 1B-4 - Body ground | Always | 10 kΩ or higher |
Reconnect the mass air flow meter connector.
Reinstall the No. 1 integration relay.
OK
NG
Repair or replace the harness or connector.
NEXT
Check the ECM power source circuit (See page Engine / Hybrid System>1KD-FTV (ENGINE CONTROL)>ECD SYSTEM>ECM Power Source Circuit).
NEXT
Replace the mass air flow meter (See page Engine / Hybrid System>1KD-FTV (ENGINE CONTROL)>MASS AIR FLOW METER>REMOVAL).
NEXT
Connect the intelligent tester to the DLC3.
Clear the DTCs (See page Engine / Hybrid System>1KD-FTV (ENGINE CONTROL)>ECD SYSTEM>DTC CHECK / CLEAR).
Start the engine and wait for 3 seconds or more.
Enter the following menus: Powertrain / Engine and ECT / DTC.
Read the DTCs.
| Result | Proceed to |
|---|---|
| P0102 or P0103 | A |
| No output | B |
A
B
Replace the ECM (See page Engine / Hybrid System>1KD-FTV (ENGINE CONTROL)>ECM>REMOVAL).
NEXT
Connect the intelligent tester to the DLC3.
Clear the DTCs (See page Engine / Hybrid System>1KD-FTV (ENGINE CONTROL)>ECD SYSTEM>DTC CHECK / CLEAR).
Start the engine and wait for 3 seconds or more.
Enter the following menus: Powertrain / Engine and ECT / DTC.
Confirm that the DTC is not output again.
NEXT