Refer to DTC P208B (See page Engine / Hybrid System>1GD-FTV (ENGINE CONTROL)>ECD SYSTEM (w/ Urea SCR System)>P208B).
| DTC Detection Drive Pattern | DTC Detection Condition | Trouble Area |
|---|---|---|
| Engine switch on (IG) for 3 seconds | An open or short circuit occurs in the pressure sensor circuit for 3 seconds or more.
(1 trip detection logic) |
·
Open or short in pressure sensor circuit ·
Pressure sensor (Urea pump) ·
Urea pump control ECU |
| DTC Detection Drive Pattern | DTC Detection Condition | Trouble Area |
|---|---|---|
| Engine switch on (IG) for 3 seconds | An open or short circuit occurs in the pressure sensor circuit for 3 seconds or more.
(1 trip detection logic) |
·
Open or short in pressure sensor circuit ·
Pressure sensor (Urea pump) ·
Urea pump control ECU |
| DTC No. | Data List |
|---|---|
| P204C
P204D |
Reductant Pressure |
Read freeze frame data using the GTS. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, and other data from the time the malfunction occurred.
Connect the GTS to the DLC3.
Turn the engine switch on (IG) and turn the GTS on.
Enter the following menus: Powertrain / Engine and ECT / Data List / Reductant Pressure.
Read the Data List according to the display on the GTS.
| Result | Proceed to |
|---|---|
| -50 kPa | A |
| 900 kPa | B |
A
B
Disconnect the pressure sensor (urea pump) connector.
Connect terminals s2-5 (VPSE) and s2-4 (PSE) of the pressure sensor (urea pump) wire harness side connector.
Connect the GTS to the DLC3.
Turn the engine switch on (IG) and turn the GTS on.
Enter the following menus: Powertrain / Engine and ECT / Data List / Reductant Pressure.
Read the Data List according to the display on the GTS.
900 kPa
| *a | Front view of wire harness connector
(to Pressure Sensor (Urea Pump)) |
OK
NG
Replace the urea pump (See page Engine / Hybrid System>1GD-FTV (EMISSION CONTROL)>UREA PUMP>REMOVAL).
NEXT
Connect the GTS to the DLC3.
Turn the engine switch on (IG) and turn the GTS on.
Clear the DTCs (See page Engine / Hybrid System>1GD-FTV (ENGINE CONTROL)>ECD SYSTEM (w/ Urea SCR System)>DTC CHECK / CLEAR).
Turn the engine switch off and wait for at least 30 seconds.
NEXT
Connect the GTS to the DLC3.
Turn the engine switch on (IG) and wait for 3 seconds or more.
Turn the GTS on.
Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.
Confirm that the DTC is not output again.
NEXT
| *a | Front view of wire harness connector
(to Pressure Sensor (Urea Pump)) |
*b | Front view of wire harness connector
(to Urea Pump Control ECU) |
Disconnect the pressure sensor (urea pump) connector.
Disconnect the urea pump control ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| s2-5 (VPSE) - s3-57 (VCPU) | Always | Below 1 Ω |
| s2-4 (PSE) - s3-56 (PU) | Always | Below 1 Ω |
| s2-3 (EPSE) - s3-55 (EPU) | Always | Below 1 Ω |
| s2-5 (VPSE) or s3-57 (VCPU) - Body ground and other terminals | Always | 10 kΩ or higher |
| s2-4 (PSE) or s3-56 (PU) - Body ground and other terminals | Always | 10 kΩ or higher |
| s2-3 (EPSE) or s3-55 (EPU) - Body ground and other terminals | Always | 10 kΩ or higher |
OK
NG
Replace the urea pump control ECU (See page Engine / Hybrid System>1GD-FTV (EMISSION CONTROL)>UREA PUMP CONTROL ECU>REMOVAL).
NEXT
Repair or replace harness or connector.
NEXT
Disconnect the pressure sensor (urea pump) connector.
Connect the GTS to the DLC3.
Turn the engine switch on (IG) and turn the GTS on.
Enter the following menus: Powertrain / Engine and ECT / Data List / Reductant Pressure.
Read the Data List according to the display on the GTS.
-50 kPa
NG
OK
| *a | Front view of wire harness connector
(to Pressure Sensor (Urea Pump)) |
*b | Front view of wire harness connector
(to Urea Pump Control ECU) |
Disconnect the pressure sensor (urea pump) connector.
Disconnect the urea pump control ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| s2-5 (VPSE) - s3-57 (VCPU) | Always | Below 1 Ω |
| s2-4 (PSE) - s3-56 (PU) | Always | Below 1 Ω |
| s2-3 (EPSE) - s3-55 (EPU) | Always | Below 1 Ω |
| s2-5 (VPSE) or s3-57 (VCPU) - Body ground and other terminals | Always | 10 kΩ or higher |
| s2-4 (PSE) or s3-56 (PU) - Body ground and other terminals | Always | 10 kΩ or higher |
| s2-3 (EPSE) or s3-55 (EPU) - Body ground and other terminals | Always | 10 kΩ or higher |
OK