Home › Engine / Hybrid System › 1GD-FTV (ENGINE CONTROL) › ECD SYSTEM (w/ Urea SCR System) › 2015.06–2017.08
RM27T0E _51 Engine / Hybrid System _053660 1GD-FTV ENGINE CONTROL _0260461 ECD SYSTEM(w/ Urea SCR System) C

1GD-FTV ENGINE CONTROL  ECD SYSTEM(w/ Urea SCR System)  P204C  Reductant Pressure Sensor Circuit Low  P204D  Reductant Pressure Sensor Circuit High  


DESCRIPTION

Refer to DTC P208B (See page Engine / Hybrid System>1GD-FTV (ENGINE CONTROL)>ECD SYSTEM (w/ Urea SCR System)>P208B).

P204C
DTC Detection Drive Pattern DTC Detection Condition Trouble Area
Engine switch on (IG) for 3 seconds An open or short circuit occurs in the pressure sensor circuit for 3 seconds or more.
(1 trip detection logic)
·

Open or short in pressure sensor circuit

·

Pressure sensor (Urea pump)

·

Urea pump control ECU



P204D
DTC Detection Drive Pattern DTC Detection Condition Trouble Area
Engine switch on (IG) for 3 seconds An open or short circuit occurs in the pressure sensor circuit for 3 seconds or more.
(1 trip detection logic)
·

Open or short in pressure sensor circuit

·

Pressure sensor (Urea pump)

·

Urea pump control ECU



Related Data List
DTC No. Data List
P204C
P204D
Reductant Pressure

WIRING DIAGRAM

A357972E02
1.323,0.438 1.938,0.635 0.615,0.198 10 false VPSE 1.417,1.031 1.875,1.229 0.458,0.198 10 false PSE 1.344,1.573 1.958,1.771 0.615,0.198 10 false EPSE 1.802,0.573 1.958,0.771 0.156,0.198 10 false 5 1.802,1.135 1.958,1.333 0.156,0.198 10 false 4 1.802,1.677 1.958,1.875 0.156,0.198 10 false 3 0.333,2.042 0.646,2.24 0.313,0.198 10 false s2 0.344,2.229 4.469,2.427 4.125,0.198 10 false Pressure Sensor (Urea Pump) 5.688,0.458 6.302,0.656 0.615,0.198 10 false VCPU 5.708,1.031 6.021,1.229 0.313,0.198 10 false PU 5.708,1.583 6.167,1.781 0.458,0.198 10 false EPU 5.385,0.573 5.698,0.771 0.313,0.198 10 false 57 5.396,1.146 5.708,1.344 0.313,0.198 10 false 56 5.396,1.698 5.708,1.896 0.313,0.198 10 false 55 5.417,2.042 5.729,2.24 0.313,0.198 10 false s3 5.417,2.219 6.979,2.427 1.563,0.208 10 false Urea Pump Control ECU

CAUTION / NOTICE / HINT

HINT:

Read freeze frame data using the GTS. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, and other data from the time the malfunction occurred.


PROCEDURE

1.READ VALUE USING GTS (REDUCTANT PRESSURE)
a.

Connect the GTS to the DLC3.


b.

Turn the engine switch on (IG) and turn the GTS on.


c.

Enter the following menus: Powertrain / Engine and ECT / Data List / Reductant Pressure.


d.

Read the Data List according to the display on the GTS.

Result
Result Proceed to
-50 kPa A
900 kPa B



A

2.READ VALUE USING GTS (CHECK FOR OPEN IN WIRE HARNESS)

B

9.READ VALUE USING GTS (CHECK FOR SHORT IN WIRE HARNESS)
2.READ VALUE USING GTS (CHECK FOR OPEN IN WIRE HARNESS)
a.
U169588E02
1.813,1.573 2.229,2.417 false 1.625,1.573 1.198,2.417 false 1.635,0.667 2.146,0.875 0.51,0.208 10 false s2 0.177,0.115 0.688,0.323 0.51,0.208 10 false *a 0.938,2.469 1.448,2.677 0.51,0.208 10 false VPSE 2.156,2.469 2.667,2.677 0.51,0.208 10 false PSE

Disconnect the pressure sensor (urea pump) connector.


b.

Connect terminals s2-5 (VPSE) and s2-4 (PSE) of the pressure sensor (urea pump) wire harness side connector.


c.

Connect the GTS to the DLC3.


d.

Turn the engine switch on (IG) and turn the GTS on.


e.

Enter the following menus: Powertrain / Engine and ECT / Data List / Reductant Pressure.


f.

Read the Data List according to the display on the GTS.

OK:

900 kPa

Text in Illustration
*a Front view of wire harness connector
(to Pressure Sensor (Urea Pump))




OK

3.REPLACE UREA PUMP

NG

6.CHECK HARNESS AND CONNECTOR (PRESSURE SENSOR (UREA PUMP) - UREA PUMP CONTROL ECU)
3.REPLACE UREA PUMP

NEXT

4.CLEAR DTC
4.CLEAR DTC
a.

Connect the GTS to the DLC3.


b.

Turn the engine switch on (IG) and turn the GTS on.



d.

Turn the engine switch off and wait for at least 30 seconds.



NEXT

5.CHECK DTC OUTPUT
5.CHECK DTC OUTPUT
a.

Connect the GTS to the DLC3.


b.

Turn the engine switch on (IG) and wait for 3 seconds or more.


c.

Turn the GTS on.


d.

Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.


e.

Confirm that the DTC is not output again.



NEXT

END

6.CHECK HARNESS AND CONNECTOR (PRESSURE SENSOR (UREA PUMP) - UREA PUMP CONTROL ECU)
U169577E02
1.99,0.781 2.406,1.427 false 1.865,0.781 1.802,1.427 false 1.76,0.781 1.177,1.427 false 5.594,1.135 4.5,1.458 false 5.729,1.146 5.948,1.479 false 5.667,1.146 5.26,1.479 false 0.958,1.438 1.469,1.646 0.51,0.208 10 false VPSE 1.635,1.438 2.146,1.646 0.51,0.208 10 false PSE 2.219,1.438 2.729,1.646 0.51,0.208 10 false EPSE 1.729,0.177 2.156,0.375 0.427,0.198 10 false s2 5.396,0.177 5.823,0.375 0.427,0.198 10 false s3 0.563,0.094 1.073,0.302 0.51,0.208 10 false *a 4.125,0.094 4.635,0.302 0.51,0.208 10 false *b 4.125,1.49 4.802,1.698 0.677,0.208 10 false 55 (EPU) 4.99,1.49 5.667,1.698 0.677,0.208 10 false 56 (PU) 5.688,1.479 6.448,1.688 0.76,0.208 10 false 57 (VCPU)

Text in Illustration
*a Front view of wire harness connector
(to Pressure Sensor (Urea Pump))
*b Front view of wire harness connector
(to Urea Pump Control ECU)

a.

Disconnect the pressure sensor (urea pump) connector.


b.

Disconnect the urea pump control ECU connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
s2-5 (VPSE) - s3-57 (VCPU) Always Below 1 Ω
s2-4 (PSE) - s3-56 (PU) Always Below 1 Ω
s2-3 (EPSE) - s3-55 (EPU) Always Below 1 Ω
s2-5 (VPSE) or s3-57 (VCPU) - Body ground and other terminals Always 10 kΩ or higher
s2-4 (PSE) or s3-56 (PU) - Body ground and other terminals Always 10 kΩ or higher
s2-3 (EPSE) or s3-55 (EPU) - Body ground and other terminals Always 10 kΩ or higher




OK

7.REPLACE UREA PUMP CONTROL ECU

NG

8.REPAIR OR REPLACE HARNESS OR CONNECTOR
7.REPLACE UREA PUMP CONTROL ECU

NEXT

4.CLEAR DTC
8.REPAIR OR REPLACE HARNESS OR CONNECTOR
a.

Repair or replace harness or connector.



NEXT

4.CLEAR DTC
9.READ VALUE USING GTS (CHECK FOR SHORT IN WIRE HARNESS)
a.

Disconnect the pressure sensor (urea pump) connector.


b.

Connect the GTS to the DLC3.


c.

Turn the engine switch on (IG) and turn the GTS on.


d.

Enter the following menus: Powertrain / Engine and ECT / Data List / Reductant Pressure.


e.

Read the Data List according to the display on the GTS.

OK:

-50 kPa




NG

10.CHECK HARNESS AND CONNECTOR (PRESSURE SENSOR (UREA PUMP) - UREA PUMP CONTROL ECU)

OK

3.REPLACE UREA PUMP
10.CHECK HARNESS AND CONNECTOR (PRESSURE SENSOR (UREA PUMP) - UREA PUMP CONTROL ECU)
U169577E02
1.99,0.781 2.406,1.427 false 1.865,0.781 1.802,1.427 false 1.76,0.781 1.177,1.427 false 5.594,1.135 4.5,1.458 false 5.729,1.146 5.948,1.479 false 5.667,1.146 5.26,1.479 false 0.958,1.438 1.469,1.646 0.51,0.208 10 false VPSE 1.635,1.438 2.146,1.646 0.51,0.208 10 false PSE 2.219,1.438 2.729,1.646 0.51,0.208 10 false EPSE 1.729,0.177 2.156,0.375 0.427,0.198 10 false s2 5.396,0.177 5.823,0.375 0.427,0.198 10 false s3 0.563,0.094 1.073,0.302 0.51,0.208 10 false *a 4.125,0.094 4.635,0.302 0.51,0.208 10 false *b 4.125,1.49 4.802,1.698 0.677,0.208 10 false 55 (EPU) 4.99,1.49 5.667,1.698 0.677,0.208 10 false 56 (PU) 5.688,1.479 6.448,1.688 0.76,0.208 10 false 57 (VCPU)

Text in Illustration
*a Front view of wire harness connector
(to Pressure Sensor (Urea Pump))
*b Front view of wire harness connector
(to Urea Pump Control ECU)

a.

Disconnect the pressure sensor (urea pump) connector.


b.

Disconnect the urea pump control ECU connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
s2-5 (VPSE) - s3-57 (VCPU) Always Below 1 Ω
s2-4 (PSE) - s3-56 (PU) Always Below 1 Ω
s2-3 (EPSE) - s3-55 (EPU) Always Below 1 Ω
s2-5 (VPSE) or s3-57 (VCPU) - Body ground and other terminals Always 10 kΩ or higher
s2-4 (PSE) or s3-56 (PU) - Body ground and other terminals Always 10 kΩ or higher
s2-3 (EPSE) or s3-55 (EPU) - Body ground and other terminals Always 10 kΩ or higher




OK

7.REPLACE UREA PUMP CONTROL ECU

NG

8.REPAIR OR REPLACE HARNESS OR CONNECTOR