77830A
1.REMOVE UREA TANK CAP ASSEMBLY
51226A
2.REMOVE FRONT SUSPENSION MEMBER BRACKET LH
82169
3.DISCONNECT NO. 3 FRAME WIRE
77840
4.DISCONNECT UREA TUBE WITH HEATER ASSEMBLY
Check for dirt or mud on the urea pump and around the urea tube connector before disconnection. Clean if necessary.
Detach the 2 clamps and disconnect the urea tube with the heater assembly from the urea tank sub-assembly.
Disconnect the urea tube with heater assembly from the urea pump.
|
Pinch |
|
Pull |
Pinch the retainer of the urea tube connector, and then pull the urea tube connector off of the urea tube with heater assembly.
If there is any solidified urea solution (white solids) on the connection area, clean the solids off with a damp cloth, etc., before disconnecting the connector.
Be sure to disconnect the urea tube connector by hand.
Check for foreign matter in the urea pump and around the urea tube connector. Clean if necessary. Foreign matter may damage the O-ring or cause leaks in the seal between the urea pump and urea tube connector.
Put the urea pump and urea tube connector ends in plastic bags to prevent damage and foreign matter contamination.
77871
5.REMOVE UREA PUMP
| *a | Co-rotation Prevention Check Mark |
Apply a co-rotation prevention check mark to the urea pump from the urea tank sub-assembly.
If the urea pump and urea tank sub-assembly are not firmly attached and the urea pump gauge retainer is rotated, the urea pump will co-rotate and result in the urea pump being damaged.
Make sure to apply co-rotation prevention check mark to prevent the urea pump from co-rotating.
| *1 | Urea Pump Gauge Retainer |
| *a | SST (Claw Set) |
| *b | Rib |
| *c | Cutout |
| *d | SST (Claw Set) Incorrect Installation Point (Rotational Start Point Mark of Urea Pump Gauge Retainer) |
Set 4 SST (claw sets) to the urea pump gauge retainer and temporarily install.
Align the cutout of SST (claw set) to the rib of the urea pump gauge retainer.
Do not place SST on the rotational start paint mark of the urea pump gauge retainer, otherwise SST (claw set) cannot be set correctly.
| *1 | Urea Pump Gauge Retainer |
| *a | Hook |
| *b | SST (Claw Set) |
| *c | Screwdriver |
|
Pinch |
|
SST (Bolt) |
Using a screwdriver, while firmly pressing SST (claw set) into rib of the urea pump gauge retainer, tighten the bolt.
| *a | SST (Claw Set) |
| *b | SST (Plate) |
|
SST (Bolt) |
Temporarily install SST (plate) to SST (claw set) with 4 SST (bolts).
| *a | SST (Plate) |
| *b | Center of Urea Pump Gauge Retainer |
Adjust the position of SST (plate) so that the setting hole of SST (handle) aligns with the center of the urea pump gauge retainer.
| *1 | Urea Pump Gauge Retainer |
| *a | Rib |
| *b | SST (Claw Set) |
| *c | SST (Plate) |
| *d | SST (Bolt) |
|
Press |
While firmly pressing SST (claw set) into rib of the urea pump gauge retainer, tighten SST (bolt).
Check that SST (claw set) is securely installed to the urea pump gauge retainer to prevent it from dropping.
| *a | SST (Plate) |
| *b | SST (Handle) |
|
Loosen |
Install SST (handle) to SST (plate), slowly tighten the urea pump gauge retainer (approximately 90 to 180°) and then drain urea solution (AdBlue) into the container.
Do not use any tools other than SST, such as screwdriver, etc.
Do not apply excessive force when pressing on SST, as urea pump will place excessive force on the urea pump gauge retainer and be difficult to remove, and parts may be damaged.
Do not use an impact wrench or turn SST handle with excessive force, as parts may be damaged.
When urea solution (AdBlue) stops draining, shake the urea pump to drain the remaining urea solution (AdBlue) inside the urea tank sub-assembly.
Further loosen the urea pump gauge retainer slightly, shake the urea pump and then check that urea solution (AdBlue) in the urea tank sub-assembly does not drain.
While one person slowly loosens the urea pump gauge retainer, and another supports the urea pump so that it does not rotate or fall, remove the urea pump gauge retainer, urea pump and gasket.
If the urea pump gauge retainer is turned while the urea pump and urea tank sub-assembly are not correctly aligned, urea pump will move with the urea pump gauge retainer, and the urea pump and urea tank sub-assembly may both be damaged.
Do not rotate the urea pump gauge retainer when the co-rotation prevention check mark is out of place.