Home › Engine / Hybrid System › 1GD-FTV (EMISSION CONTROL) › UREA PUMP › 2015.06–2017.08
RM27T0E _51 Engine / Hybrid System _053675 1GD-FTV EMISSION CONTROL _0260631 UREA PUMP A

1GD-FTV EMISSION CONTROL  UREA PUMP  REMOVAL  


PROCEDURE

Hide 77830A 1.REMOVE UREA TANK CAP ASSEMBLY

Hide 82169 3.DISCONNECT NO. 3 FRAME WIRE

Hide 77840 4.DISCONNECT UREA TUBE WITH HEATER ASSEMBLY

NOTICE:

Check for dirt or mud on the urea pump and around the urea tube connector before disconnection. Clean if necessary.


a.
A462611

Detach the 2 clamps and disconnect the urea tube with the heater assembly from the urea tank sub-assembly.


b.

Disconnect the urea tube with heater assembly from the urea pump.

i.
A462655C01
0,0 0,0 false
V100135

Pinch
V100136

Pull


Pinch the retainer of the urea tube connector, and then pull the urea tube connector off of the urea tube with heater assembly.

NOTICE:
·

If there is any solidified urea solution (white solids) on the connection area, clean the solids off with a damp cloth, etc., before disconnecting the connector.

·

Be sure to disconnect the urea tube connector by hand.

·

Check for foreign matter in the urea pump and around the urea tube connector. Clean if necessary. Foreign matter may damage the O-ring or cause leaks in the seal between the urea pump and urea tube connector.

·

Put the urea pump and urea tube connector ends in plastic bags to prevent damage and foreign matter contamination.





Hide 77871 5.REMOVE UREA PUMP

a.
A462613C01
1.313,0.656 0.521,0.771 0.521,0.771 0.354,0.771 true 0.563,0.76 1.125,0.458 true 0.135,0.688 0.344,0.865 0.208,0.177 10 true *a
*a Co-rotation Prevention Check Mark


Apply a co-rotation prevention check mark to the urea pump from the urea tank sub-assembly.

NOTICE:
·

If the urea pump and urea tank sub-assembly are not firmly attached and the urea pump gauge retainer is rotated, the urea pump will co-rotate and result in the urea pump being damaged.

·

Make sure to apply co-rotation prevention check mark to prevent the urea pump from co-rotating.




b.
A462597C01
0.323,0.354 0.469,0.354 0.469,0.354 0.75,0.583 true 0.979,0.667 1.271,0.667 true 2.448,0.896 2.146,0.677 2.146,0.677 2,0.677 true 2.448,1.021 2.74,1.344 2.74,1.344 2.865,1.344 true 0.302,1.531 0.448,1.531 0.448,1.531 0.792,2.115 true 0.135,0.281 0.448,0.438 0.313,0.156 10 false *1 1.292,0.583 1.604,0.74 0.313,0.156 10 false *a 1.833,0.594 2.146,0.75 0.313,0.156 10 false *b 2.885,1.26 3.198,1.417 0.313,0.156 10 false *c 0.115,1.448 0.427,1.604 0.313,0.156 10 false *d
*1 Urea Pump Gauge Retainer
*a SST (Claw Set)
*b Rib
*c Cutout
*d SST (Claw Set) Incorrect Installation Point (Rotational Start Point Mark of Urea Pump Gauge Retainer)


Set 4 SST (claw sets) to the urea pump gauge retainer and temporarily install.

SST
09808-14031  (09808-01080, 09808-01090, 09808-01100)

NOTICE:
·

Align the cutout of SST (claw set) to the rib of the urea pump gauge retainer.

·

Do not place SST on the rotational start paint mark of the urea pump gauge retainer, otherwise SST (claw set) cannot be set correctly.




c.
A462598C01
1.073,0.177 1.25,0.177 1.25,0.177 1.646,0.26 true 1.823,1.448 2.396,1.813 2.396,1.813 2.573,1.813 true 2.521,0.646 2.385,0.646 2.385,0.646 2.094,0.292 true 0.51,1.865 0.688,1.865 0.688,1.865 1.302,1.604 true 2.563,0.583 2.875,0.74 0.313,0.156 10 true *1 0.896,0.094 1.104,0.25 0.208,0.156 10 false *a 2.604,1.74 2.833,1.885 0.229,0.146 10 false *b 0.313,1.771 0.542,1.917 0.229,0.146 10 false *c
*1 Urea Pump Gauge Retainer
*a Hook
*b SST (Claw Set)
*c Screwdriver
V100135

Pinch
V100136

SST (Bolt)


Using a screwdriver, while firmly pressing SST (claw set) into rib of the urea pump gauge retainer, tighten the bolt.


d.
A462599C01
1.271,0.698 0.781,0.5 0.781,0.5 0.583,0.5 true 2.802,1.813 3.146,1.813 true 0.396,0.417 0.615,0.573 0.219,0.156 10 true *a 3.167,1.74 3.385,1.896 0.219,0.156 10 false *b
*a SST (Claw Set)
*b SST (Plate)
V100135

SST (Bolt)


Temporarily install SST (plate) to SST (claw set) with 4 SST (bolts).

SST
09808-14031  (09808-01030, 09808-01090)


e.
A462600C01
1.74,1.115 2.646,1.333 2.646,1.333 2.927,1.333 true 1.083,0.427 0.729,0.302 0.729,0.302 0.521,0.302 true 0.344,0.219 0.656,0.375 0.313,0.156 10 false *a 2.969,1.26 3.281,1.417 0.313,0.156 10 false *b
*a SST (Plate)
*b Center of Urea Pump Gauge Retainer


Adjust the position of SST (plate) so that the setting hole of SST (handle) aligns with the center of the urea pump gauge retainer.


f.
A462601C01
2.146,0.5 2.448,0.198 2.448,0.198 2.646,0.198 true 1.031,2.5 1.24,2.5 1.24,2.5 1.948,2.74 true 1.177,0.198 1.396,0.198 1.396,0.198 1.792,0.51 true 1.635,3.281 1.844,3.281 1.844,3.281 2.5,3.073 true 1.708,1.146 1.146,1.146 false 2.688,0.115 3,0.271 0.313,0.156 10 false *1 1,0.115 1.313,0.271 0.313,0.156 10 false *a 0.979,1.063 1.292,1.219 0.313,0.156 10 false *b 0.833,2.417 1.146,2.573 0.313,0.156 10 false *c 1.458,3.198 1.771,3.354 0.313,0.156 10 false *d
*1 Urea Pump Gauge Retainer
*a Rib
*b SST (Claw Set)
*c SST (Plate)
*d SST (Bolt)
V113147

Press


While firmly pressing SST (claw set) into rib of the urea pump gauge retainer, tighten SST (bolt).

NOTICE:

Check that SST (claw set) is securely installed to the urea pump gauge retainer to prevent it from dropping.



g.
A462602C01
2.406,0.583 2.781,0.219 2.781,0.219 2.958,0.219 true 1.594,1.385 1.115,1.75 1.115,1.75 0.844,1.75 true 2.979,0.125 3.292,0.281 0.313,0.156 10 false *a 0.656,1.677 0.969,1.833 0.313,0.156 10 false *b
*a SST (Plate)
*b SST (Handle)
V113147

Loosen


Install SST (handle) to SST (plate), slowly tighten the urea pump gauge retainer (approximately 90 to 180°) and then drain urea solution (AdBlue) into the container.

SST
09808-14031  (09808-01010, 09808-01020)

NOTICE:
·

Do not use any tools other than SST, such as screwdriver, etc.

·

Do not apply excessive force when pressing on SST, as urea pump will place excessive force on the urea pump gauge retainer and be difficult to remove, and parts may be damaged.

·

Do not use an impact wrench or turn SST handle with excessive force, as parts may be damaged.




h.

When urea solution (AdBlue) stops draining, shake the urea pump to drain the remaining urea solution (AdBlue) inside the urea tank sub-assembly.


i.

Further loosen the urea pump gauge retainer slightly, shake the urea pump and then check that urea solution (AdBlue) in the urea tank sub-assembly does not drain.


j.

While one person slowly loosens the urea pump gauge retainer, and another supports the urea pump so that it does not rotate or fall, remove the urea pump gauge retainer, urea pump and gasket.

NOTICE:
·

If the urea pump gauge retainer is turned while the urea pump and urea tank sub-assembly are not correctly aligned, urea pump will move with the urea pump gauge retainer, and the urea pump and urea tank sub-assembly may both be damaged.

·

Do not rotate the urea pump gauge retainer when the co-rotation prevention check mark is out of place.