Home › Engine / Hybrid System › 1GD-FTV (EMISSION CONTROL) › UREA TANK › 2015.06–2017.08
RM27T0E _51 Engine / Hybrid System _053675 1GD-FTV EMISSION CONTROL _0260632 UREA TANK A

1GD-FTV EMISSION CONTROL  UREA TANK  REMOVAL  


PROCEDURE

Hide 33030 1.REMOVE MANUAL TRANSMISSION UNIT ASSEMBLY (for Manual Transmission)

Hide 35000 2.REMOVE AUTOMATIC TRANSMISSION ASSEMBLY (for Automatic Transmission)

Hide 53737A 3.REMOVE NO. 1 FRONT FENDER APRON TO FRAME SEAL LH

a.

Remove the 5 clips and No. 1 front fender apron to frame seal LH from the body.


Hide 82169 4.DISCONNECT NO. 3 FRAME WIRE

a.
A355526

Disconnect the connector from the urea tube with heater assembly.


b.

Detach the clamp from the urea tank sub-assembly.


c.
A355528

Pull the tabs of the connector as shown in the illustration and disconnect the connector from the urea pump


Hide 77840 5.DISCONNECT UREA TUBE WITH HEATER ASSEMBLY

a.

Disconnect the urea tube with heater assembly from the urea injector set (See page Engine / Hybrid System>1GD-FTV (EMISSION CONTROL)>UREA INJECTOR>REMOVAL).


b.
A356544

Detach the 4 clamps and disconnect the urea tube with heater assembly from the frame crossmember and urea tank sub-assembly.


Hide 77903 6.DISCONNECT UREA TANK BREATHER TUBE SUB-ASSEMBLY

NOTICE:

Check for dirt or mud on the urea tank filler pipe and around the urea tank breather tube connector before disconnection. Clean if necessary.


a.

Disconnect the urea tank breather tube sub-assembly from the urea tank filler pipe assembly.

i.
A356545E01
0.496,0.878 0.766,1.132 0.27,0.254 1.571,1.204 0.955,1.011 0.955,1.011 0.734,1.011 false 0.533,0.909 0.710,1.078 0.177,0.169 10 *a

Detach the claw of the retainer of the urea tank breather tube connector, pull up the retainer and disconnect the urea tank breather tube connector from the urea tank filler pipe assembly.

Text in Illustration
*a Retainer
V100135

Pull
V100136

Pull Out

NOTICE:
·

If there is any solidified urea solution (white solids) on the connection area, clean the solids off with a damp cloth, etc., before disconnecting the connector.

·

Be sure to disconnect the urea tank breather tube connector by hand.

·

Check for foreign matter in the urea tank filler pipe assembly and around the urea tank breather tube connector. Clean if necessary. Foreign matter may damage the O-ring or cause leaks in the seal between the urea tank filler pipe assembly and urea tank breather tube connector.

·

Put the urea tank filler pipe assembly and urea tank breather tube connector ends in plastic bags to prevent damage and foreign matter contamination.





Hide 77902 7.DISCONNECT UREA TANK FILLER TUBE SUB-ASSEMBLY

NOTICE:

Check for dirt or mud on the urea tank filler pipe and around the urea tank filler tube connector before disconnection. Clean if necessary.


a.

Disconnect the urea tank filler tube sub-assembly from the urea tank filler pipe assembly.

i.
A356547E01
0.622,1.253 0.874,1.477 0.253,0.225 1.678,1.206 1.027,1.357 1.027,1.357 0.874,1.357 false 0.667,1.259 0.850,1.450 0.183,0.191 10 *a

Detach the claw of the retainer of the urea tank filler tube connector, pull up the retainer and disconnect the urea tank filler tube connector from the urea tank filler pipe assembly.

Text in Illustration
*a Retainer
V100135

Push
V100136

Pull Out

NOTICE:
·

If there is any solidified urea solution (white solids) on the connection area, clean the solids off with a damp cloth, etc., before disconnecting the connector.

·

Be sure to disconnect the urea tank filler tube connector by hand.

·

Check for foreign matter in the urea tank filler pipe assembly and around the urea tank filler tube connector. Clean if necessary. Foreign matter may damage the O-ring or cause leaks in the seal between the urea tank filler pipe assembly and urea tank filler tube connector.

·

Put the urea tank filler pipe assembly and urea tank filler tube connector ends in plastic bags to prevent damage and foreign matter contamination.





Hide 77801 8.REMOVE UREA TANK SUB-ASSEMBLY

a.
A356553

Remove the 2 bolts and urea tank sub-assembly from the flame LH.


Hide 77903 9.REMOVE UREA TANK BREATHER TUBE SUB-ASSEMBLY

NOTICE:

Check for dirt or mud on the urea tank sub-assembly and around the urea tank breather tube connector before disconnection. Clean if necessary.


a.

Detach the clamp and remove the urea tank breather tube sub-assembly from the urea tank sub-assembly.

i.
A356554E01
1.248,0.538 1.537,0.324 1.537,0.324 1.651,0.324 false 1.657,0.225 1.837,0.383 0.180,0.159 10 *a

Detach the claw of the retainer of the urea tank breather tube connector, pull up the retainer and disconnect the urea tank breather tube connector from the urea tank sub-assembly.

Text in Illustration
*a Retainer
V100135

Pull
V100136

Pull Out

NOTICE:
·

If there is any solidified urea solution (white solids) on the connection area, clean the solids off with a damp cloth, etc., before disconnecting the connector.

·

Be sure to disconnect the urea tank breather tube connector by hand.

·

Check for foreign matter in the urea tank sub-assembly and around the urea tank breather tube connector. Clean if necessary. Foreign matter may damage the O-ring or cause leaks in the seal between the urea tank sub-assembly and urea tank breather tube connector.

·

Put the urea tank sub-assembly and urea tank breather tube connector ends in plastic bags to prevent damage and foreign matter contamination.





Hide 77902 10.REMOVE UREA TANK FILLER TUBE SUB-ASSEMBLY

NOTICE:

Check for dirt or mud on the urea tank sub-assembly and around the urea tank filler tube connector before disconnection. Clean if necessary.


a.

Detach the clamp and remove the urea tank filler tube sub-assembly from the urea tank sub-assembly.

i.
A356556E01
1.846,0.134 2.019,0.296 0.172,0.162 10 *a 1.524,0.455 1.75,0.233 1.75,0.233 1.838,0.233 false

Detach the claw of the retainer of the urea tank filler tube connector, pull up the retainer and disconnect the urea tank filler tube connector from the urea tank sub-assembly.

Text in Illustration
*a Retainer
V100135

Pull
V100136

Pull Out

NOTICE:
·

If there is any solidified urea solution (white solids) on the connection area, clean the solids off with a damp cloth, etc., before disconnecting the connector.

·

Be sure to disconnect the urea tank filler tube connector by hand.

·

Check for foreign matter in the urea tank sub-assembly and around the urea tank filler tube connector. Clean if necessary. Foreign matter may damage the O-ring or cause leaks in the seal between the urea tank sub-assembly and urea tank filler tube connector.

·

Put the tank sub-assembly and urea tank filler tube connector ends in plastic bags to prevent damage and foreign matter contamination.





Hide 77840 11.REMOVE UREA TUBE WITH HEATER ASSEMBLY

NOTICE:

Check for dirt or mud on the urea pump and around the urea tube connector before disconnection. Clean if necessary.


a.

Remove the urea tube with heater assembly from the urea pump.

i.
A356560C04
0,0 0,0 false
V100135

Pinch
V100136

Pull


Pinch the retainer of the urea tube connector, and then pull the urea tube connector off of the urea tube with heater assembly.

NOTICE:
·

If there is any solidified urea solution (white solids) on the connection area, clean the solids off with a damp cloth, etc., before disconnecting the connector.

·

Be sure to disconnect the urea tube connector by hand.

·

Check for foreign matter in the urea pump and around the urea tube connector. Clean if necessary. Foreign matter may damage the O-ring or cause leaks in the seal between the urea pump and urea tube connector.

·

Put the urea pump and urea tube connector ends in plastic bags to prevent damage and foreign matter contamination.





Hide 77871 12.REMOVE UREA PUMP

a.
A460321C01
2.104,1.5 2.74,1.167 2.74,1.167 2.958,1.167 true 2.302,1.698 2.75,1.177 true 3,1.083 3.313,1.281 0.313,0.198 10 true *a
*a Co-rotation Prevention Check Mark


Apply a co-rotation prevention check mark to the urea pump from the urea tank sub-assembly.

NOTICE:
·

If the urea pump and urea tank sub-assembly are not firmly attached and the urea pump gauge retainer is rotated, the urea pump will co-rotate and result in the urea pump being damaged.

·

Make sure to apply co-rotation prevention check mark to prevent the urea pump from co-rotating.




b.
A412502C01
0.375,3.531 0.5,3.531 0.5,3.531 0.729,3.823 true 0.708,0.688 0.938,0.688 true 1.156,1 1.635,1 true 1.135,2.875 1.271,2.875 1.271,2.875 1.573,2.635 true 1.01,2.094 1.146,2.094 1.146,2.094 1.573,2.438 true 1.688,0.938 1.927,1.083 0.24,0.146 10 false *1 0.5,0.615 0.698,0.771 0.198,0.156 10 false *a 0.948,2.813 1.156,2.969 0.208,0.156 10 false *b 0.813,2.021 1.021,2.188 0.208,0.167 10 false *c 0.188,3.469 0.385,3.604 0.198,0.135 10 false *d
*1 Urea Pump Gauge Retainer
*a SST (Claw Set)
*b Rib
*c Cutout
*d SST (Claw Set) Incorrect Installation Point (Rotational Start Point Mark of Urea Pump Gauge Retainer)


Set 4 SST (claw sets) to the urea pump gauge retainer and temporarily install.

SST
09808-14031  (09808-01080, 09808-01090, 09808-01100)

NOTICE:
·

Align the cutout of SST (claw set) to the rib of the urea pump gauge retainer.

·

Do not place SST on the rotational start paint mark of the urea pump gauge retainer, otherwise SST (claw set) cannot be set correctly.




c.
A412503C01
2.094,1.427 2.479,0.969 2.479,0.969 2.708,0.969 true 1.375,1.063 0.813,0.875 0.813,0.875 0.656,0.875 false 1.094,1.833 0.677,1.99 0.677,1.99 0.521,1.99 true 2.76,0.906 2.99,1.073 0.229,0.167 10 false *1 0.448,0.813 0.656,0.958 0.208,0.146 10 false *a 0.333,1.917 0.552,2.073 0.219,0.156 10 false *b
*1 Urea Pump Gauge Retainer
*a SST (Claw Set)
*b Hook
V100135

Pinch
V100136

SST (Bolt)


While firmly pressing the claw of SST into rib of the urea pump gauge retainer, tighten the bolt.


d.
A460322C01
1.031,0.427 0.656,0.25 0.656,0.25 0.49,0.25 true 2.094,1.479 2.646,1.354 2.646,1.354 2.833,1.354 true 0.292,0.167 0.521,0.354 0.229,0.188 10 false *a 2.875,1.271 3.104,1.458 0.229,0.188 10 false *b
*a SST (Plate)
*b SST (Claw Set)
V100135

SST (Bolt)


Temporarily install SST (plate) to SST (claw set) with 4 SST (bolts).

SST
09808-14031  (09808-01030, 09808-01090)


e.
A460323C01
2.052,1.417 2.823,1.417 true 1.802,1.188 0.885,0.896 0.885,0.896 0.719,0.896 true 0.531,0.813 0.76,0.979 0.229,0.167 10 false *a 2.865,1.344 3.094,1.51 0.229,0.167 10 false *b
*a Center of Urea Pump Gauge Retainer
*b SST (Plate)


Adjust the position of SST (plate) so that the setting hole of SST (handle) aligns with the center of the urea pump gauge retainer.


f.
A460324C01
2.25,0.188 2.01,0.188 2.01,0.188 1.042,0.354 true 1.26,2.677 1.031,2.365 1.031,2.365 0.875,2.365 true 1.75,2.281 2.344,2.281 true 2.302,0.813 2.063,0.813 2.063,0.813 1.229,0.542 true 2.198,3.25 2.052,3.25 2.052,3.25 1.656,2.885 true 2.281,0.104 2.521,0.281 0.24,0.177 10 true *a 2.385,2.208 2.583,2.354 0.198,0.146 10 false *b 2.344,0.719 2.583,0.896 0.24,0.177 10 false *c 2.229,3.156 2.438,3.323 0.208,0.167 10 false *d 0.698,2.281 0.938,2.458 0.24,0.177 10 false *1
*1 Urea Pump Gauge Retainer
*a SST (Plate)
*b SST (Claw Set)
*c SST (Bolt)
*d Rib
V113147

Press


While firmly pressing SST (claw set) into rib of the urea pump gauge retainer, tighten SST (bolt).


g.
A460325C02
1.323,1.417 0.781,1.229 0.781,1.229 0.646,1.229 true 1.156,0.604 1.615,0.281 1.615,0.281 1.792,0.281 true 0.458,1.146 0.677,1.302 0.219,0.156 10 false *a 1.833,0.208 2.052,0.365 0.219,0.156 10 false *b
*a SST (Plate)
*b SST (Handle)
V113147

Loosen


Install SST (handle) to SST (plate).

SST
09808-14031  (09808-01010, 09808-01020)


h.

Slowly loosen the urea pump gauge retainer by approximately 90°.

NOTICE:
·

Do not use any tools other than SST, such as screwdriver, etc.

·

Do not apply excessive force when pressing down on SST, as urea pump will place excessive force on the urea pump gauge retainer and be difficult to remove, and parts may be damaged.

·

Do not use an impact wrench or turn SST handle with excessive force, as parts may be damaged.




i.

While on person slowly loosens the urea pump gauge retainer, have another person press down the rising urea pump, and then remove the urea pump gauge retainer while making sure that the urea pump is properly aligned.

NOTICE:
·

If the urea pump gauge retainer is turned while the urea pump and urea tank sub-assembly are not correctly aligned, urea pump will move with the urea pump gauge retainer, and the urea pump and urea tank sub-assembly may both be damaged.

·

Do not rotate the urea pump gauge retainer when the co-rotation prevention check mark is out of place.



A460326C01
6.344,1.146 6.688,0.844 6.688,0.844 6.865,0.844 true 6.49,1.302 6.677,0.865 true 1.146,1.125 0.531,1.125 true 0.885,0.469 1.104,0.219 1.104,0.219 1.219,0.219 true 0.333,1.031 0.646,1.188 0.313,0.156 10 true *a 1.26,0.135 1.573,0.292 0.313,0.156 10 true *b 2.052,1.573 2.281,1.74 0.229,0.167 10 true *c 4.917,0.375 5.135,0.531 0.219,0.156 10 true *d 6.885,0.76 7.115,0.927 0.229,0.167 10 true *e 4.188,0.042 4.406,0.198 0.219,0.156 10 true *d 1.729,0.229 1.948,0.385 0.219,0.156 10 true *d 2.333,0.604 2.552,0.76 0.219,0.156 10 true *d 0.073,0.344 0.302,0.51 0.229,0.167 10 true *c 2.948,0.552 3.177,0.719 0.229,0.167 10 true *c 4.458,1.281 4.688,1.448 0.229,0.167 10 true *c
*a SST (Plate) *b SST (Handle)
*c Person in Charge of Loosening *d Person in Charge of Supporting
*e Co-rotation Prevention Check Mark - -



j.
A356564

Remove the urea pump from the urea tank sub-assembly.


k.
A356565

Remove the gasket from the urea tank sub-assembly.


Hide 77861 13.REMOVE NO. 1 UREA TANK BRACKET

a.
A355508

Remove the bolt and No. 1 urea tank bracket from the urea tank sub-assembly.


Hide 77862 14.REMOVE NO. 2 UREA TANK BRACKET

a.
A355509

Remove the bolt and No. 2 urea tank bracket from the urea tank sub-assembly.