Home › Power Source / Network › 1GR-FE (BATTERY / CHARGING) › GENERATOR › 2015.06–2020.08
RM27T0E _57 Power Source / Network _053724 1GR-FE BATTERY / CHARGING _0261019 GENERATOR A

1GR-FE BATTERY / CHARGING  GENERATOR  REMOVAL  


PROCEDURE

Hide 1.DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

NOTICE:
·

After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).

·

When disconnecting the cable, some systems need to be initialized after the cable is reconnected (See page General>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION).



Hide 2.DISCONNECT CABLE FROM POSITIVE BATTERY TERMINAL

Hide 74481 3.REMOVE BATTERY HOLD DOWN CLAMP

a.
A223416

Loosen the 2 nuts and remove the battery hold down clamp.


Hide 28800 4.REMOVE BATTERY

Hide 74431 5.REMOVE BATTERY TRAY

Hide 16604 8.REMOVE NO. 2 IDLER PULLEY SUB-ASSEMBLY

a.
A223415

for Integrated Type:

Remove the bolt and No. 2 idler pulley.


b.

for Separate Type:

Remove the bolt, No. 2 idler pulley cover plate, No. 2 idler pulley and idler pulley cover plate.


Hide 9.REMOVE WIRING HARNESS CLAMP BRACKET

a.
A222903

Detach the clamp.


b.

Remove the bolt and wiring harness clamp bracket.


Hide 17168 10.REMOVE NO. 2 EXHAUST MANIFOLD HEAT INSULATOR

Hide 27060 11.REMOVE GENERATOR ASSEMBLY

a.
A222881

Open the terminal cap.


b.

Remove the nut and disconnect the wire harness from terminal B.


c.

Disconnect the generator connector from the generator assembly.


d.
A222884

Remove the 2 bolts and disconnect the wire harness.


e.
A222882

Disconnect the wire harness clamp.


f.

Remove the bolt and disconnect the generator bracket.


g.
A222883

Remove the 2 bolts and generator assembly.


h.
A222885

Remove the bolt and generator bracket.