Home › Power Source / Network › 2TR-FE (BATTERY / CHARGING) › GENERATOR › 2015.06–2020.08
RM27T0E _57 Power Source / Network _053725 2TR-FE BATTERY / CHARGING _0261021 GENERATOR A

2TR-FE BATTERY / CHARGING  GENERATOR  REMOVAL  


PROCEDURE

Hide 1. PRECAUTION

NOTICE:

After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work.

(See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION)


Hide 2.DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

NOTICE:

When disconnecting the cable, some systems need too be initialized after the cable is reconnected.

(See page General>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION)


Hide 17705 3.REMOVE AIR CLEANER CAP SUB-ASSEMBLY WITH AIR CLEANER HOSE

Hide 27020 5.REMOVE GENERATOR ASSEMBLY

a.
A223928

Disconnect the connector from the generator assembly.


b.

Remove the terminal cap.


c.

Remove the nut and disconnect the wire harness from terminal B.


d.
A351763

Remove the 3 bolts and generator assembly.