When the rear power seat switch is operated, a recline signal is sent to the fold seat control ECU. The ECU activates the power seat motor based on the signal from the rear power seat switch.
Remove the fold seat control ECU with its connectors still connected (See page Vehicle Interior>SEAT>REAR NO. 2 SEAT ASSEMBLY (for Power Seat Type LH Side)>DISASSEMBLY).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| d1-12 (RCLF) - Body ground | Always | 11 to 14 V |
| Rear power seat switch LH forward | Below 1 V | |
| d1-13 (RCLR) - Body ground | Always | 11 to 14 V |
| Rear power seat switch LH backward | Below 1 V |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| c1-12 (RCLF) - Body ground | Always | 11 to 14 V |
| Rear power seat switch RH forward | Below 1 V | |
| c1-13 (RCLR) - Body ground | Always | 11 to 14 V |
| Rear power seat switch RH backward | Below 1 V |
| *A | for LH Side |
| *B | for RH Side |
| *a | Component with harness connected
(Fold Seat Control ECU) |
OK
NG
Remove the rear power seat switch (See page Vehicle Interior>SEAT>POWER SEAT SWITCH(for Rear No. 2 Seat)>REMOVAL).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 4 (FWD) - 6 (E) | Always | 10 kΩ or higher |
| Rear power seat switch forward | Below 1 Ω | |
| 5 (BACK) - 6 (E) | Always | 10 kΩ or higher |
| Rear power seat switch backward | Below 1 Ω |
OK
NG
*1: for LH Side
*2: for RH Side
Disconnect the d1*1 or c1*2 ECU connector.
Disconnect the R11*1 or Q10*2 switch connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| d1-12 (RCLF) - R11-4 (FWD) | Always | Below 1 Ω |
| d1-12 (RCLF) - Body ground | Always | 10 kΩ or higher |
| d1-13 (RCLR) - R11-5 (BACK) | Always | Below 1 Ω |
| d1-13 (RCLR) - Body ground | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| c1-12 (RCLF) - Q10-4 (FWD) | Always | Below 1 Ω |
| c1-12 (RCLF) - Body ground | Always | 10 kΩ or higher |
| c1-13 (RCLR) - Q10-5 (BACK) | Always | Below 1 Ω |
| c1-13 (RCLR) - Body ground | Always | 10 kΩ or higher |
OK
NG