This DTC is stored when refrigerant pressure is extremely low (0.176 MPa [1.8 kgf/cm2, 25.5 psi] or less) or extremely high (3.025 MPa [30.9 kgf/cm2, 438.6 psi] or higher). The air conditioner pressure sensor, which is installed on the pipe of the high pressure side to detect refrigerant pressure, outputs the refrigerant pressure signal to the air conditioning amplifier assembly. The air conditioning amplifier assembly converts the signal to a pressure value according to the sensor characteristics to control the compressor.
Be sure to check the refrigerant volume first when this DTC is output because this DTC may also be stored if there is no refrigerant in the cycle.
| DTC Code | DTC Detection Condition | Trouble Area |
|---|---|---|
| B1423/23 | Either condition is met:
·
An open or short in the air conditioner pressure sensor circuit. ·
Refrigerant pressure on the high pressure side is extremely low or extremely high. |
·
Air conditioner pressure sensor ·
Harness or connector ·
Cooler expansion valve ·
Cooler condenser assembly ·
Cooler dryer ·
Refrigerant pipe line ·
Air conditioning amplifier assembly |
Disconnect the A2 sensor connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A2-3 (+) - Body ground | Ignition switch ON | 4.75 to 5.25 V |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A2-1 (-) - Body ground | Always | Below 1 Ω |
| *a | Front view of wire harness connector
(to Air Conditioning Pressure Sensor) |
OK
NG
Reconnect the A2 sensor connector.
Remove the air conditioning amplifier assembly with its connectors still connected (See page Vehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING AMPLIFIER>REMOVAL).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| G25-9 (PRE) - Body ground | Ignition switch ON
A/C switch off |
0.63 to 4.72 V |
| *a | Component with harness connected
(Air Conditioning Amplifier Assembly) |
If the measured voltage is not within the normal range, there may be a malfunction in the air conditioning amplifier assembly, air conditioner pressure sensor or wire harness. It is also possible that the amount of refrigerant may not be appropriate.
OK
NG
Measure the voltage when the following conditions are met.
| Item | Condition |
|---|---|
| Engine Speed | 2000 rpm |
| Vehicle Doors | Fully open |
| Temperature Setting | MAX COOL |
| Blower Speed | Hi |
| A/C Switch | On |
| R/F Switch | Recirculation |
| Interior Temperature | 25 to 35°C (77 to 95°F) |
If refrigerant pressure on the high pressure side becomes extremely high during the inspection (the voltage exceeds 4.8 V), the fail-safe function stops compressor operation. Therefore, measure the voltage before the fail-safe operation.
It is necessary to measure the voltage for a certain amount of time (approximately 10 minutes) because the problem symptom may recur after a while.
When the outside air temperature is low (below -1.5°C [29.3°F]), the compressor stops due to operation of the ambient temperature sensor and evaporator temperature sensor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G25-9 (PRE) - Body ground | Above measurement condition | 0.63 to 4.72 V |
| *a | Component with harness connected
(Air Conditioning Amplifier Assembly) |
| Result | Proceed to |
|---|---|
| OK (When troubleshooting according to problem symptoms table) | A |
| OK (When troubleshooting according to the DTC) | B |
| NG | C |
A
B
C
Disconnect the G25 amplifier connector.
Disconnect the A2 sensor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A2-1 (-) - G25-13 (SG-2) | Always | Below 1 Ω |
| A2-3 (+) - G25-10 (S5-3) | Always | Below 1 Ω |
| G25-13 (SG-2) - Body ground | Always | 10 kΩ or higher |
| G25-10 (S5-3) - Body ground | Always | 10 kΩ or higher |
OK
NG
Disconnect the G25 amplifier connector.
Disconnect the A2 sensor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A2-2 (PR) - G25-9 (PRE) | Always | Below 1 Ω |
| G25-9 (PRE) - Body ground | Always | 10 kΩ or higher |
OK
NG
Install a manifold gauge set.
Recover the refrigerant from the air conditioning system using a refrigerant recovery unit.
Evacuate the air conditioning system and check that vacuum can be maintained in it.
Vacuum can be maintained in the air conditioning system.
If vacuum cannot be maintained in the air conditioning system, refrigerant may be leaking from it. In this case, it is necessary to repair or replace the leaking part of the air conditioning system.
OK
NG
Add an appropriate amount of refrigerant (See page Vehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT>REPLACEMENT).
NEXT
Check for DTCs when the following conditions are met (See page Vehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System)>DTC CHECK / CLEAR).
| Item | Condition |
|---|---|
| Engine Speed | 2000 rpm |
| Vehicle Doors | Fully open |
| Temperature Setting | MAX COOL |
| Blower Speed | Hi |
| A/C Switch | On |
| R/F Switch | Recirculation |
| Interior Temperature | 25 to 35°C (77 to 95°F) |
If refrigerant pressure on the high pressure side becomes high, a DTC will be stored. Therefore, it is necessary to check for DTCs after a certain amount of time (approximately 10 minutes) has passed because the DTC may be stored after the air conditioning system operates for a while.
When the outside air temperature is low (below -1.5°C [29.3°F]), the compressor stops due to operation of the ambient temperature sensor and evaporator temperature sensor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.
DTC B1423 is not output.
If the DTC was stored due to an insufficient or excessive amount of refrigerant, the problem may have been solved after performing the previous step. However, the root cause of insufficient refrigerant may be refrigerant leakage. Therefore, identify and repair the area where refrigerant leaks as necessary. The root cause of excessive refrigerant may be adding too much refrigerant.
OK
NG
Install a manifold gauge set.
Reconnect the A2 sensor connector.
Remove the air conditioning amplifier assembly with its connectors still connected (See page Vehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING AMPLIFIER>REMOVAL).
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| G25-9 (PRE) - G25-13 (SG-2) | ·
Ignition switch ON ·
Refrigerant pressure normal (below 3.025 MPa [30.9 kgf/cm2, 438.6 psi] and higher than 0.176 MPa [1.8 kgf/cm2, 25.5 psi]) |
0.63 to 4.72 V |
·
Ignition switch ON ·
Refrigerant pressure abnormal (below 0.176 MPa [1.8 kgf/cm2, 25.5 psi]) |
Below 0.63 V | |
·
Ignition switch ON ·
Refrigerant pressure abnormal (higher than 3.025 MPa [30.9 kgf/cm2, 438.6 psi]) |
4.72 V or higher |
| *a | Component with harness connected
(Air Conditioning Amplifier Assembly) |
OK
NG
Identify the area where refrigerant leaks (See page Vehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT>REPLACEMENT).
Repair the identified area of the air conditioning system.
Evacuate the air conditioning system.
NEXT
Use a refrigerant recovery unit to recover refrigerant.
Evacuate the air conditioning system.
Add an appropriate amount of refrigerant (See page Vehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT>REPLACEMENT).
If refrigerant is added and the system has not been properly evacuated (insufficient vacuum time), moisture in the air remaining in the system will freeze in the expansion valve, blocking the flow on the high pressure side. Therefore, in order to confirm the problem, recover the refrigerant and properly evacuate the system. Add an appropriate amount of refrigerant, and then check for the DTC.
NEXT
Check for DTCs when the following conditions are met (See page Vehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System)>DTC CHECK / CLEAR).
| Item | Condition |
|---|---|
| Engine Speed | 2000 rpm |
| Vehicle Doors | Fully open |
| Temperature Setting | MAX COOL |
| Blower Speed | Hi |
| A/C Switch | On |
| R/F Switch | Recirculation |
| Interior Temperature | 25 to 35°C (77 to 95°F) |
If refrigerant pressure on the high pressure side becomes high, a DTC will be stored. Therefore, it is necessary to check for DTCs after a certain amount of time (approximately 10 minutes) has passed because the DTC may be stored after the air conditioning system operates for a while.
When the outside air temperature is low (below -1.5°C [29.3°F]), the compressor stops due to operation of the ambient temperature sensor and evaporator temperature sensor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.
If refrigerant is added and the system has not been properly evacuated (insufficient vacuum time), moisture in the air remaining in the system will freeze in the expansion valve, blocking the flow on the high pressure side. Therefore, in order to confirm the problem, recover the refrigerant and properly evacuate the system. Add an appropriate amount of refrigerant and check for the DTC. If the DTC is not output after this procedure, it indicates that the cooler dryer in the cooler condenser assembly is not able to absorb moisture in the refrigerant cycle. In this case, to complete the repair, it is necessary to replace the cooler dryer.
DTC B1423 is not output.
OK
NG
Replace the cooler expansion valve with a new or normally functioning one (See page Vehicle Interior>HEATING / AIR CONDITIONING>FRONT AIR CONDITIONING UNIT>DISASSEMBLY).
Replace the cooler expansion valve with a new or normally functioning one because the cooler expansion valve is either stuck or clogged.
NEXT
Add an appropriate amount of refrigerant (See page Vehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT>REPLACEMENT).
NEXT
Check for DTCs when the following conditions are met.
| Item | Condition |
|---|---|
| Engine Speed | 2000 rpm |
| Vehicle Doors | Fully open |
| Temperature Setting | MAX COOL |
| Blower Speed | Hi |
| A/C Switch | On |
| R/F Switch | Recirculation |
| Interior Temperature | 25 to 35°C (77 to 95°F) |
If refrigerant pressure on the high pressure side becomes high, a DTC will be stored. Therefore, it is necessary to check for DTCs after a certain amount of time (approximately 10 minutes) has passed because the DTC may be stored after the air conditioning system operates for a while.
When the outside air temperature is low (below -1.5°C [29.3°F]), the compressor stops due to operation of the ambient temperature sensor and evaporator temperature sensor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.
If refrigerant pressure is not normal after replacing the expansion valve with a new or normally functioning one, the cooler condenser assembly or pipes may be clogged due to dirt, dust or other contaminants. In this case, clean or replace the cooler condenser assembly or pipes.
DTC B1423 is not output.
OK
NG