77862
1.INSTALL NO. 2 UREA TANK BRACKET
Install the No. 2 urea tank bracket to the urea tank sub-assembly with the bolt.
77861
2.INSTALL NO. 1 UREA TANK BRACKET
Install the No. 1 urea tank bracket to the urea tank sub-assembly with the bolt.
77871
3.INSTALL UREA PUMP
Install a new gasket to the urea tank sub-assembly.
| *a | Matchmark |
Install the urea pump to the urea tank sub-assembly as shown in the illustration.
| *a | Co-rotation Prevention Check Mark |
Apply a co-rotation prevention check mark to the urea pump.
Perform this procedure when replacement of the urea pump is necessary.
| *a | Rotational Start Point Mark (Urea Pump Gauge Retainer Side) |
| *b | Rotational Start Point Mark (Urea Tank Sub-assembly Side) |
Temporarily place the urea pump gauge retainer by aligning the rotational start point mark of the urea pump gauge retainer with the rotational start point mark of the urea tank sub-assembly.
| *1 | Urea Pump Gauge Retainer |
| *a | SST (Claw Set) |
| *b | Rib |
| *c | Cutout |
| *d | SST (Claw Set) Incorrect Installation Point (Rotational Start Point Mark of Urea pump Gauge Retainer) |
Set 4 SST (claw sets) to the urea pump gauge retainer and temporarily install.
Align the cutout of SST (claw set) to the rib of the urea pump gauge retainer.
Do not place SST on the rotational start paint mark of the urea pump gauge retainer, otherwise SST (claw set) cannot be set correctly.
| *1 | Urea Pump Gauge Retainer |
| *a | SST (Claw Set) |
| *b | Hook |
|
Pinch |
|
SST (Bolt) |
While firmly pressing the claw of SST into rib of the urea pump gauge retainer, tighten the bolt.
| *a | SST (Plate) |
| *b | SST (Claw Set) |
|
SST (Bolt) |
Temporarily install SST (plate) to SST (claw set) with 4 SST (bolts).
| *a | Center of Urea Pump Gauge Retainer |
| *b | SST (Plate) |
Adjust the position of SST (plate) so that the setting hole of SST (handle) aligns with the center of the urea pump gauge retainer.
| *1 | Urea Pump Gauge Retainer |
| *a | SST (Plate) |
| *b | SST (Claw Set) |
| *c | SST (Bolt) |
| *d | Rib |
|
Press |
While firmly pressing SST (claw set) into rib of the urea pump gauge retainer, tighten SST (bolt).
| *a | Tighten Start Position |
| *b | Co-rotation Prevention Check Mark |
While one person presses the urea pump into the urea tank sub-assembly, have another person firmly press the urea pump gauge retainer into the threads of the urea tank assembly and tighten approximately one turn.
Do not any tools other than SST, such as a screwdriver, etc.
Do not apply excessive force when pressing down on SST, as the urea pump will place excessive force on urea pump gauge retainer and be difficult to remove, and parts may be damaged.
Do not use an impact wrench or turn SST handle with excessive force, as parts may be damaged.
Do not rotate the urea pump gauge retainer when the co-rotation prevention check mark is out of place.
| *a | SST (Plate) |
| *b | Person in Change of Tightening |
| *c | Person in Charge of Supporting |
While one person presses the urea pump into the urea tank sub-assembly, have another person slowly tighten it.
| *a | SST (Handle) |
| *b | SST (Plate) |
| *c | Person in Charge of Supporting |
| *d | Person in Charge of Tightening |
| *e | Rotational Start Point Mark of Urea Pump Gauge Retainer |
|
Tighten |
Install SST (handle) to SST (plate).
While one person presses the urea pump onto the urea tank sub-assembly, have another person use SST (handle) and slowly tighten the urea pump gauge retainer is within range A on the urea tank sub-assembly as shown in the illustration.
77840
4.INSTALL UREA TUBE WITH HEATER ASSEMBLY
Check for dirt or mud on the urea pump and around the urea tube with heater connector before connection. Clean if necessary.
Install the urea tube with heater assembly to the urea pump.
If there is any solidified urea solution (white solids) on the connection areas of the urea tube with heater assembly and urea pump, clean the solids off with water. Otherwise, they may prevent the O-ring from sealing properly.
Wash the connection area of the urea tube with heater connector with water to remove all solidified urea solution (white solids).
Wipe off the connection area of the urea pump with water to remove all solidified urea solution (white solids).
| *a | Retainer |
|
Push |
|
Push Down |
Align the axis of the connector with the axis of the urea injector set. Push the urea tube with heater connector into the urea pump until the urea tube with heater connector makes a "click" sound.
Push down the retainer.
After connecting the urea pump and the urea tube with heater connector, check that the urea pump and urea tube with heater connector are securely connected by trying to pull them apart.
77903
5.INSTALL UREA TANK BREATHER TUBE SUB-ASSEMBLY
Check for dirt or mud on the urea tank sub-assembly and around the urea tank breather tube connector before connection. Clean if necessary.
Attach the clamp and install the urea tank breather tube sub-assembly to the urea tank sub-assembly.
If there is any solidified urea solution (white solids) on the connection areas of the urea tank breather tube sub-assembly and urea tank sub-assembly, clean the solids off with water. Otherwise, they may prevent the O-ring from sealing properly.
Wash the connection area of the urea tank breather tube connector with water to remove all solidified urea solution (white solids).
Wipe off the connection area of the urea tank sub-assembly with water to remove all solidified urea solution (white solids).
| *a | Retainer |
|
Push |
|
Push Down |
Align the axis of the connector with the axis of the urea tank sub-assembly. Push the urea tank breather tube connector into the urea tank sub-assembly until the urea tank breather tube connector makes a "click" sound.
Push down the retainer.
After connecting the urea tank sub-assembly and the urea tank breather tube connector, check that the urea tank sub-assembly and urea tank breather tube connector are securely connected by trying to pull them apart.
77801
6.INSTALL UREA TANK SUB-ASSEMBLY
Install the urea tank sub-assembly to the frame LH with the 2 bolts.
77900
7.CONNECT UREA TANK FILLER PIPE WITH SUPPORT ASSEMBLY
Check for dirt or mud on the urea tank breather tube sub-assembly, urea tank sub-assembly and around the urea tank filler pipe with support connector before connection. Clean if necessary.
Connect the urea tank filler pipe with support assembly to the urea tank breather tube sub-assembly.
If there is any solidified urea solution (white solids) on the connection areas of the urea tank filler pipe with support assembly and urea tank breather tube sub-assembly, clean the solids off with water. Otherwise, they may prevent the O-ring from sealing properly.
Wash the connection area of the urea tank filler pipe with support connector with water to remove all solidified urea solution (white solids).
Wipe off the connection area of the urea tank breather tube sub-assembly with water to remove all solidified urea solution (white solids).
| *a | Retainer |
|
Push |
|
Push Down |
Align the axis of the connector with the axis of the urea tank breather tube sub-assembly. Push the urea tank filler pipe with support connector into the urea tank breather tube sub-assembly until the urea tank filler pipe with support connector makes a "click" sound.
Push down the retainer.
After connecting the urea tank breather tube sub-assembly and the urea tank filler pipe with support connector, check that the urea tank breather tube sub-assembly and urea tank filler pipe with support connector are securely connected by trying to pull them apart.
Connect the urea tank filler pipe with support assembly to the urea tank sub-assembly.
If there is any solidified urea solution (white solids) on the connection areas of the urea tank filler pipe with support assembly and urea tank sub-assembly, clean the solids off with water. Otherwise, they may prevent the O-ring from sealing properly.
Wash the connection area of the urea tank filler pipe with support connector with water to remove all solidified urea solution (white solids).
Wipe off the connection area of the urea tank sub-assembly with water to remove all solidified urea solution (white solids).
| *a | Retainer |
|
Push |
|
Push Down |
Align the axis of the connector with the axis of the urea tank sub-assembly. Push the urea tank filler pipe with support connector into the urea tank sub-assembly until the urea tank filler pipe with support connector makes a "click" sound.
Push down the retainer.
After connecting the urea tank sub-assembly and the urea tank filler pipe with support connector, check that the urea tank sub-assembly and urea tank filler pipe with support connector are securely connected by trying to pull them apart.
77840
8.CONNECT UREA TUBE WITH HEATER ASSEMBLY
Attach the 4 clamps and connect the urea tube with heater assembly to the frame crossmember and urea tank sub-assembly.
Connect the urea tube with heater assembly to the urea injector set (See page Engine / Hybrid System>1GD-FTV (EMISSION CONTROL)>UREA INJECTOR>INSTALLATION).
82169
9.CONNECT NO. 3 FRAME WIRE
Connect the connector to the urea pump as shown in the illustration.
Attach the clamp to the urea pump.
Connect the connector to the urea tube with heater assembly.
53737A
10.INSTALL NO. 1 FRONT FENDER APRON TO FRAME SEAL LH
Install the No. 1 front fender apron to frame seal LH to the body with the 5 clips.
35000
11.INSTALL AUTOMATIC TRANSMISSION ASSEMBLY (for Automatic Transmission)
33030
12.INSTALL MANUAL TRANSMISSION UNIT ASSEMBLY (for Manual Transmission)