Home › Engine / Hybrid System › 1GD-FTV (ENGINE CONTROL) › ECD SYSTEM (w/ Urea SCR System) › 2017.08–2020.08
RM27T0E _51 Engine / Hybrid System _053660 1GD-FTV ENGINE CONTROL _0260461 ECD SYSTEM(w/ Urea SCR System) C

1GD-FTV ENGINE CONTROL  ECD SYSTEM(w/ Urea SCR System)  P203C  Reductant Level Sensor Circuit Low  P203D  Reductant Level Sensor Circuit High  


DESCRIPTION

The urea pump has a level sensor that detects the position of the surface of the fluid inside the urea tank in order to measure the remaining quantity of urea solution.

When the remaining quantity of urea solution falls below a fixed value, a warning is displayed on the combination meter.

P203C
DTC Detection Drive Pattern DTC Detection Condition Trouble Area
Engine switch on (IG) for 3 seconds or more An open or short in the level sensor (urea pump) circuit for 3 seconds or more.
(1 trip detection logic).
·

Open or short in the level sensor circuit

·

Level sensor (urea pump)

·

Urea pump control ECU



P203D
DTC Detection Drive Pattern DTC Detection Condition Trouble Area
Engine switch on (IG) for 3 seconds or more An open or short in the level sensor (urea pump) circuit for 3 seconds or more.
(1 trip detection logic)
·

Open or short in the level sensor circuit

·

Level sensor (urea pump)

·

Urea pump control ECU



Related Data List
DTC No. Data List
P203C
P203D
Reductant Level

WIRING DIAGRAM

A357972E06
1.396,0.438 2.01,0.635 0.615,0.198 10 false VLV1 1.49,1.031 1.948,1.229 0.458,0.198 10 false LV1 1.417,1.573 2.031,1.771 0.615,0.198 10 false ELV1 1.802,0.573 2.052,0.771 0.25,0.198 10 false 13 1.802,1.135 2.083,1.354 0.281,0.219 10 false 14 1.823,1.677 2.115,1.885 0.292,0.208 10 false 6 0.333,2.042 0.646,2.24 0.313,0.198 10 false s3 0.344,2.229 4.469,2.427 4.125,0.198 10 false Level Sensor (Urea Pump) 5.688,0.458 6.302,0.656 0.615,0.198 10 false VCLU 5.708,1.031 6.021,1.229 0.313,0.198 10 false LVU 5.729,1.583 6.188,1.781 0.458,0.198 10 false ELU 5.385,0.573 5.698,0.771 0.313,0.198 10 false 60 5.396,1.146 5.708,1.344 0.313,0.198 10 false 59 5.396,1.698 5.708,1.896 0.313,0.198 10 false 58 5.417,2.042 5.729,2.24 0.313,0.198 10 false s4 5.417,2.219 6.979,2.427 1.563,0.208 10 false Urea Pump Control ECU

CAUTION / NOTICE / HINT

HINT:

Read freeze frame data using the GTS. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, and other data from the time the malfunction occurred.


PROCEDURE

1.INSPECT LEVEL SENSOR (UREA PUMP)
a.

Inspect the level sensor (urea pump) (See page Engine / Hybrid System>1GD-FTV (EMISSION CONTROL)>UREA PUMP>INSPECTION).



OK

2.CHECK HARNESS AND CONNECTOR (LEVEL SENSOR (UREA PUMP) - UREA PUMP CONTROL ECU)

NG

7.REPLACE UREA PUMP
2.CHECK HARNESS AND CONNECTOR (LEVEL SENSOR (UREA PUMP) - UREA PUMP CONTROL ECU)
U169580E03
1.75,0.938 2.406,1.427 false 1.656,0.938 1.802,1.427 false 1.635,0.792 1.177,1.427 false 5.792,1.146 4.948,1.448 false 5.938,1.146 6.396,1.438 false 5.865,1.146 5.708,1.469 false 0.958,1.438 1.469,1.646 0.51,0.208 10 false ELV1 1.677,1.438 2.188,1.646 0.51,0.208 10 false LV1 2.302,1.438 2.813,1.646 0.51,0.208 10 false VLV1 1.729,0.177 2.156,0.375 0.427,0.198 10 false s3 5.396,0.177 5.823,0.375 0.427,0.198 10 false s4 0.563,0.094 1.073,0.302 0.51,0.208 10 false *a 4.125,0.094 4.635,0.302 0.51,0.208 10 false *b 4.542,1.458 5.219,1.667 0.677,0.208 10 false 58 (ELU) 5.438,1.458 6.115,1.667 0.677,0.208 10 false 59 (LVU) 6.177,1.458 6.938,1.667 0.76,0.208 10 false 60 (LU )

Text in 1llustration
*a Front view of wire harness connector
(to Level Sensor (Urea Pump))
*b Front view of wire harness connector
(to Urea Pump Control ECU)

a.

Disconnect the level sensor (urea pump) connector.


b.

Disconnect the urea pump control ECU connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
s3-13 (VLV1) - s4-60 (VCLU) Always Below 1 Ω
s3-14 (LV1) - s4-59 (LVU) Always Below 1 Ω
s3-6 (ELV1) - s4-58 (ELU) Always Below 1 Ω
s3-13 (VLV1) or s4-60 (VCLU) - Body ground and other terminals Always 10 kΩ or higher
s3-14 (LV1) or s4-59 (LVU) - Body ground and other terminals Always 10 kΩ or higher
s3-6 (ELV1) or s4-58 (ELU) - Body ground and other terminals Always 10 kΩ or higher



d.

Reconnect the urea pump control ECU connector.


e.

Reconnect the level sensor (urea pump) connector.



OK

3.CHECK WHETHER DTC OUTPUT RECURS (DTC P203C OR P203D)

NG

6.REPAIR OR REPLACE HARNESS OR CONNECTOR
3.CHECK WHETHER DTC OUTPUT RECURS (DTC P203C OR P203D)
a.

Connect the GTS to the DLC3.


b.

Turn the engine switch on (IG).


c.

Turn the GTS on.



e.

Turn the engine switch off and wait for at least 30 seconds.


f.

Turn the engine switch on (IG) and wait for 3 seconds or more.


g.

Turn the GTS on.


h.

Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.


i.

Read the DTCs.

Result:
Result Proceed to
DTC P203C or P203D is output A
DTC is not output B



A

4.REPLACE UREA PUMP CONTROL ECU

B

END

4.REPLACE UREA PUMP CONTROL ECU

NEXT

5.CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED
5.CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED
a.

Connect the GTS to the DLC3.


b.

Turn the engine switch on (IG) and turn the GTS on.



d.

Turn the engine switch off and wait for at least 30 seconds.


e.

Turn the engine switch on (IG) and wait for 3 seconds or more.


f.

Turn the GTS on.


g.

Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.


h.

Confirm that the DTC is not output again.



NEXT

END

6.REPAIR OR REPLACE HARNESS OR CONNECTOR
a.

Repair or replace harness or connector.



NEXT

5.CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED
7.REPLACE UREA PUMP

NEXT

5.CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED