Refer to DTC P202B (See page Engine / Hybrid System>1GD-FTV (ENGINE CONTROL)>ECD SYSTEM (w/ Urea SCR System)>P202B).
| DTC Detection Drive Pattern | DTC Detection Condition | Trouble Area |
|---|---|---|
| Engine switch on (IG) and wait for 10 seconds or more. | An open or short circuit occurs in the temperature sensor circuit for 10 seconds or more.
(1 trip detection logic) |
·
Open or short in temperature sensor circuit ·
Temperature sensor (Urea Pump) ·
Urea pump control ECU |
| DTC Detection Drive Pattern | DTC Detection Condition | Trouble Area |
|---|---|---|
| Engine switch on (IG) and wait for 10 seconds or more. | An open or short circuit occurs in the temperature sensor circuit for 10 seconds or more.
(1 trip detection logic) |
·
Open or short in temperature sensor circuit ·
Temperature sensor (Urea Pump) ·
Urea pump control ECU |
| DTC No. | Data List |
|---|---|
| P205C
P205D |
Reductant Temperature |
The urea pump control ECU calculates the temperature of the urea solution based on the output voltage of the temperature sensor. When the temperature sensor output voltage is outside the normal range, there may be a malfunction, short or open circuit in the temperature sensor. In this case, the urea pump control ECU determines that there is a malfunction in the temperature sensor, and then illuminates the MIL and stores a DTC through the ECM.
Read freeze frame data using the GTS. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, and other data from the time the malfunction occurred.
Connect the GTS to the DLC3.
Turn the engine switch on (IG) and turn the GTS on.
Enter the following menus: Powertrain / Engine and ECT / Reductant Temperature.
Read the values.
Reductant temperature is the same as the ambient temperature of urea tank assembly.
| Result | Proceed to |
|---|---|
| -40°C (-40°F) | A |
| 80°C (176°F) | B |
When the GTS indicates -40°C (-40°F), there is a open circuit.
When the GTS indicates 80°C (176°F), there is a short circuit.
A
B
Disconnect the urea pump connector.
| *1 | Temperature Sensor (Urea Pump) | *2 | Urea Pump Control ECU |
| *a | Front view of wire harness connector
(to Urea Pump) |
- | - |
Connect terminals 1 (TUW) and 2 (ETUW) of the urea pump connector on the wire harness side.
Connect the GTS to the DLC3.
Turn the engine switch on (IG) and turn the GTS on.
Enter the following menus: Powertrain / Engine and ECT / Data List / Reductant Temperature.
Read the values.
80°C (176°F)
OK
NG
Replace the urea pump (See page Engine / Hybrid System>1GD-FTV (EMISSION CONTROL)>UREA PUMP>REMOVAL).
NEXT
Connect the GTS to the DLC3.
Turn the engine switch on (IG) and turn the GTS on.
Clear the DTCs (See page Engine / Hybrid System>1GD-FTV (ENGINE CONTROL)>ECD SYSTEM (w/ Urea SCR System)>DTC CHECK / CLEAR).
Turn the engine switch off and wait for 30 seconds or more.
Read the DTCs.
NEXT
Connect the GTS to the DLC3.
Turn the GTS on.
Turn the engine switch on (IG) and wait for 10 seconds or more.
Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.
Confirm that the DTCs are not output again.
NEXT
| *a | Front view of wire harness connector
(to Urea Pump) |
*b | Front view of wire harness connector
(to Urea Pump Control ECU) |
Disconnect the urea pump connector.
Disconnect the urea pump control ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| s3-1 (TUW) - s4-54 (THU) | Always | Below 1 Ω |
| s3-2 (ETUW) - s4-53 (ETHU) | Always | Below 1 Ω |
OK
NG
Replace the urea pump control ECU (See page Engine / Hybrid System>1GD-FTV (EMISSION CONTROL)>UREA PUMP CONTROL ECU>REMOVAL).
NEXT
Repair or replace the harness or connector.
NEXT
Disconnect the urea pump assembly connector.
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
Enter the following menus: Powertrain / Engine and ECT / Data List / Reductant Temperature.
Read the values.
-40°C (-40°F)
| *1 | Temperature Sensor (Urea Pump) |
| *2 | Urea Pump Control ECU |
OK
NG
| *a | Front view of wire harness connector
(to Urea Pump) |
*b | Front view of wire harness connector
(to Urea Pump Control ECU) |
Disconnect the urea pump connector.
Disconnect the urea pump control ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| s3-1 (TUW) and s4-54 (THU) - Body ground and other terminals | Always | 10 kΩ or higher |
OK
NG