When the brake pedal is depressed, the stop light switch assembly outputs a signal to the ECM. The ECM uses this signal to control cancellation of vehicle speed by the dynamic radar cruise control. When the ECM determines that terminals STP and ST1- of the stop light switch assembly are both less than 1 V, DTC P057162 is stored.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| P057162 | Brake Switch "A" Signal Compare Failure | When the ignition switch ON, and the dynamic radar cruise control system is operating, the ECM detects that the voltage at terminal STP and ST1- are both less than 1 V for approximately 0.5 seconds or more. | ·
Harness or connector ·
Stop light switch assembly ·
ECM |
Inspect the fuses for circuits related to this system before performing the following procedure.
Before replacing the ECM, refer to Service Bulletin.
| *a | Front view of wire harness connector
(to Stop Light Switch Assembly) |
Disconnect the stop light switch assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A99-2 (GND) - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A99-6 (B) - Body ground | Ignition switch off | Below 1 V |
| Ignition switch ON | 11 to 14 V | |
| A99-7 (B) - Body ground | Always | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Inspect the stop light switch assembly.
Click hereVehicle Exterior>LIGHTING (EXT)>STOP LIGHT SWITCH>ON-VEHICLE INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the G185 ECM connector.
Disconnect the A7 skid control ECU (master cylinder solenoid) connector.
w/ Entry and Start System:
Disconnect the G213 certification ECU (smart key ECU assembly) connector.
Disconnect the G150*1 or G45*2 shift lock control ECU (transmission floor shift assembly) connector.
*1: w/o Entry and Start System
*2: w/ Entry and Start System
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G185-12 (ST1-) - A99-5 (L) | Always | Below 1 Ω |
| G185-13 (STP) - A99-3 (L) | Always | Below 1 Ω |
| G185-12 (ST1-) or A99-5 (L) - Body ground | Always | 10 kΩ or higher |
| G185-13 (STP) or A99-3 (L) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG