48960
1.INSTALL NO. 2 HEIGHT CONTROL VALVE SUB-ASSEMBLY
Install the No. 2 height control valve with the 2 bolts.
2.CONNECT HEIGHT CONTROL TUBE
Connect the 3 height control tubes (See page Suspension>SUSPENSION CONTROL>SUSPENSION CONTROL SYSTEM (w/ Air Suspension)>PRECAUTION).
For the connection procedure of the tubes (type 1 and type 2), refer to Precaution of the Suspension Control System section.
Connect the connector.
3.CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
4.CHECK CONNECTION OF TUBE FOR AIR LEAK
5. INITIALIZATION AFTER RECONNECTING BATTERY TERMINAL
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART