Home › Suspension › SUSPENSION CONTROL › CONTROL VALVE ASSEMBLY › from 2020.08
RM27T0E _53 Suspension _053706 SUSPENSION CONTROL _0260875 CONTROL VALVE ASSEMBLY A

SUSPENSION CONTROL  CONTROL VALVE ASSEMBLY  INSTALLATION  


PROCEDURE

Hide 48960 1.INSTALL NO. 2 HEIGHT CONTROL VALVE SUB-ASSEMBLY

a.

Install the No. 2 height control valve with the 2 bolts.

Torque:
29 N*m (296 kgf*cm, 21 ft.*lbf)


Hide 2.CONNECT HEIGHT CONTROL TUBE

a.

Connect the 3 height control tubes (See page Suspension>SUSPENSION CONTROL>SUSPENSION CONTROL SYSTEM (w/ Air Suspension)>PRECAUTION).

HINT:

For the connection procedure of the tubes (type 1 and type 2), refer to Precaution of the Suspension Control System section.



b.

Connect the connector.


Hide 3.CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

Hide 5. INITIALIZATION AFTER RECONNECTING BATTERY TERMINAL

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE

HINT:

When disconnecting and reconnecting the battery, there is an automatic learning function that completes learning when the respective system is used.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART