P0031 Oxygen (A/F) Sensor Heater Control Circuit Low (Bank 1 Sensor 1)
Diagnostic trouble codes · Vehicles built from Jan 2012
Also covers:
- P0032 Oxygen (A/F) Sensor Heater Control Circuit High (Bank 1 Sensor 1)
- P0051 Oxygen (A/F) Sensor Heater Control Circuit Low (Bank 2 Sensor 1)
- P0052 Oxygen (A/F) Sensor Heater Control Circuit High (Bank 2 Sensor 1)
DESCRIPTION
- HINT:
- For more information on the air fuel ratio sensor and Diesel Particulate Filter (DPF), refer to the following procedures (Click here).
- These DTCs are related to the air fuel ratio sensor, although the titles say oxygen sensor.
- For more information on the air fuel ratio sensor and Diesel Particulate Filter (DPF), refer to the following procedures (Click here).
The air fuel ratio sensor is located after the Diesel Particulate Filter (DPF) catalytic converter. This sensor has been developed based on the structure and technology of the air fuel ratio sensor that is used for gasoline engines. The cover for the sensor electrode has been modified to suit its application in a diesel engine. This change allows the sensor to function effectively in this DPF type diesel engine, and it also avoids problems with sensor temperature and particulate matter (PM).
In order to reduce PM, the ECM adjusts the air-fuel ratio to a value slightly richer than that which would otherwise be used (note that this mixture is still leaner than the stoichiometric air fuel ratio). The ECM controls these adjustments on signals from the air fuel ratio sensor.
When the ECM performs PM forced regeneration (cleaning) by adding fuel using the exhaust fuel addition injector assembly, the air fuel ratio sensor feedback is used to ensure that an appropriate air fuel ratio is maintained.
*: This voltage change occurs only inside the ECM. It is not possible to measure this voltage at the sensor. The GTS can be used to monitor this voltage.


- HINT:
- The ECM provides a pulse width modulated control circuit to adjust current through the heater. The air fuel ratio sensor heater circuit uses a relay on the +B side of the circuit.


| DTC Detection Drive Pattern |
DTC Detection Condition |
Trouble Area |
|
Air fuel ratio sensor heater current is 0.8 A or less when the heater operates for 4 seconds. (1 trip detection logic) |
|
| DTC Detection Drive Pattern |
DTC Detection Condition |
Trouble Area |
| Engine switch on (IG) for 5 seconds |
Either condition is met (1 trip detection logic):
|
|
| DTC No. |
Data List |
| P0031 P0032 |
|
| P0052 P0053 |
|
MONITOR DESCRIPTION
The inner surface of the air fuel ratio sensor element is exposed to outside air. The outer surface of the sensor element is exposed to exhaust gases. The sensor element is made of platinum coated zirconia and includes an integrated heating element. The zirconia element generates a small voltage when there is a large difference in the oxygen concentrations of the exhaust and the outside air. The platinum coating amplifies the voltage generation. When heated, the sensor becomes very efficient. If the temperature of the exhaust is low, without supplemental heating, the sensor will not generate useful voltage signals. The ECM controls the heating by using a duty-cycle to regulate the average current in the heater element. If the heater current is out of the normal range, the output signals of the sensor are inaccurate and the ECM cannot regulate the air-fuel ratio properly. When the heater current is out of the normal operating range, the ECM interprets this as a malfunction and stores a DTC.WIRING DIAGRAM


INSPECTION PROCEDURE
- NOTICE:
- Inspect the fuses of circuits related to this system before performing the following inspection procedure.
- After replacing the ECM, the new ECM needs registration (Click here) and initialization (Click here).
- After replacing the fuel supply pump assembly, the ECM needs initialization (Click here).
- After replacing an injector assembly, the ECM needs registration (Click here).
- Inspect the fuses of circuits related to this system before performing the following inspection procedure.
- HINT:
- Read freeze frame data using the GTS. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, and other data from the time the malfunction occurred.
| 1. INSPECT AIR FUEL RATIO SENSOR (HEATER RESISTANCE) |
Inspect the air fuel ratio sensor (for bank 1 or bank 2) (Click here).
|
|
||||
| OK | |
| 2. CHECK TERMINAL VOLTAGE (AIR FUEL RATIO SENSOR HEATER VOLTAGE) |
Disconnect the air fuel ratio sensor connector.

Turn the engine switch on (IG).
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
Switch Condition
Specified Condition
C159-2 (+B) - Body ground
Engine switch on (IG)
11 to 14 V
C158-2 (+B) - Body ground
Engine switch on (IG)
11 to 14 V
Text in Illustration *A
for Bank 1
*B
for Bank 2
*a
Front view of wire harness connector
(to Air Fuel Ratio Sensor)
|
|
||||
| OK | |
| 3. CHECK HARNESS AND CONNECTOR (AIR FUEL RATIO SENSOR - ECM) |
Disconnect the air fuel ratio sensor connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
for LHD Tester Connection
Condition
Specified Condition
C159-1 (HAF1) - C45-45 (HA1A)
Always
Below 1 Ω
C158-1 (HAF2) - C45-46 (HA2A)
Always
Below 1 Ω
C159-1 (HAF1) or C45-45 (HA1A) - Body ground
Always
10 kΩ or higher
C158-1 (HAF2) or C45-46 (HA2A) - Body ground
Always
10 kΩ or higher
- Standard Resistance:
for RHD Tester Connection
Condition
Specified Condition
C159-1 (HAF1) - C46-45 (HA1A)
Always
Below 1 Ω
C158-1 (HAF2) - C46-46 (HA2A)
Always
Below 1 Ω
C159-1 (HAF1) or C46-45 (HA1A) - Body ground
Always
10 kΩ or higher
C158-1 (HAF2) or C46-46 (HA2A) - Body ground
Always
10 kΩ or higher
|
|
||||
| OK | |
| 4. REPLACE ECM |
Replace the ECM (Click here).
|
|
||||
| 5. INSPECT A/F RELAY |
Inspect the A/F relay (Click here).
|
|
||||
| OK | |
| 6. CHECK HARNESS AND CONNECTOR (A/F RELAY - A/F SENSOR) |
Disconnect the air fuel ratio sensor connector.
Remove the A/F relay from the engine room relay block and junction block assembly.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
C159-2 (+B) - A/F relay terminal 3
Always
Below 1 Ω
C158-2 (+B) - A/F relay terminal 3
Always
Below 1 Ω
C159-2 (+B) or A/F relay terminal 3 - Body ground
Always
10 kΩ or higher
C158-2 (+B) or A/F relay terminal 3 - Body ground
Always
10 kΩ or higher
|
|
||||
| OK | |
| 7. INSPECT INTEGRATION RELAY (EFI MAIN 2) |
Inspect the integration relay (EFI MAIN 2) (Click here).
|
|
||||
| OK | |
| 8. CHECK HARNESS AND CONNECTOR (A/F RELAY - INTEGRATION RELAY, BATTERY) |
Remove the A/F relay from the engine room relay block and junction block assembly.
Remove the integration relay from the engine room relay block and junction block assembly.
Measure the resistance according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
Switch Condition
Specified Condition
A/F relay terminal 5 - Body ground
Always
11 to 14 V
- Standard Resistance:
Tester Connection
Condition
Specified Condition
A/F relay terminal 1 - 1A-4
Always
Below 1 Ω
A/F relay terminal 2 - Body ground
Always
Below 1 Ω
A/F relay terminal 1 or 1A-4 - Body ground
Always
10 kΩ or higher
|
|
||||
| OK | |
| 9. CHECK HARNESS AND CONNECTOR (INTEGRATION RELAY - ECM) |
Remove the integration relay from the engine room relay block and junction block assembly.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
for LHD Tester Connection
Condition
Specified Condition
1A-2 - A38-44 (MREL)
Always
Below 1 Ω
1A-2 or A38-44 (MREL) - Body ground
Always
10 kΩ or higher
- Standard Resistance:
for RHD Tester Connection
Condition
Specified Condition
1A-2 - A52-44 (MREL)
Always
Below 1 Ω
1A-2 or A52-44 (MREL) - Body ground
Always
10 kΩ or higher
|
|
||||
|
|
||||
| 10. REPLACE AIR FUEL RATIO SENSOR |
- Replace the air fuel ratio sensor (for bank 1) (Click here).
- Replace the air fuel ratio sensor (for bank 2) (Click here).
|
|
||||
| 11. REPLACE A/F RELAY |
Replace the A/F relay.
|
|
||||
| 12. REPLACE INTEGRATION RELAY |
Replace the integration relay (EFI MAIN 2).
|
|
||||
| 13. REPAIR OR REPLACE HARNESS OR CONNECTOR |
Repair or replace harness or connector.
|
|
||||
| 14. CHECK ECM POWER SOURCE CIRCUIT |
Check the ECM power source circuit (Click here).
| NEXT | |
| 15. CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED |
Connect the GTS to the DLC3.
Clear the DTCs (Click here).
Turn the engine switch off for 30 seconds or more.
Turn the engine switch on (IG).
Turn the GTS on.
Drive the vehicle at 50 km/h (30 mph) or more for a total of 300 seconds or more.
- HINT:
- "Exhaust Temperature B1S1" and "Exhaust Temperature B2S1" on the GTS screen should be 200°C (392°F) or higher.
Confirm that the DTC is not output again.
- HINT:
- Perform the following procedure using the GTS to determine whether or not the DTC judgment has been carried out.
Enter the following menus: Engine and ECT / Utility / All Readiness.
Input DTC P0031, P0032, P0052 or P0053.
Check that STATUS is NORMAL.
- HINT:
- If STATUS is NORMAL, DTC judgment is complete and the system is determined to be normal.
- If STATUS is INCOMPLETE or N/A, DTC judgment is incomplete. Drive the vehicle at 50 km/h (30 mph) or more for a total of 300 seconds or more again.
- If STATUS is NORMAL, DTC judgment is complete and the system is determined to be normal.
| NEXT | ||
| ||