2011-2013 Land Cruiser · Service Manual Engine / Hybrid / EV System

ECM Power Source Circuit

Circuit diagnosis · Vehicles built from Jan 2012

DESCRIPTION

When the engine switch is turned on (IG), the battery voltage is applied to the IGSW terminal of the ECM. The output signal from the MREL terminal of the ECM causes current to flow to the coil, closing the contacts of the integration relay (EFI relay) and supplying power to terminal +B of the ECM.

WIRING DIAGRAM

A275260E01
A275260E02

INSPECTION PROCEDURE

NOTICE:
After replacing the ECM, the new ECM needs registration (Click here) and initialization (Click here).


1. INSPECT INTEGRATION RELAY (INTEGRATION RELAY - BODY GROUND)
A162268E03
  1. Remove the integration relay from the engine room relay block.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    1C-1 - Body ground
    Always
    11 to 14 V



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


2. INSPECT INTEGRATION RELAY (EFI RELAY AND IG2 RELAY)
A182246E02
  1. Remove the integration relay from the engine room relay block.

  1. Inspect the EFI MAIN fuse and the IG2 MAIN fuse.

    1. Remove the EFI MAIN fuse and IG2 MAIN fuse from the integration relay.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      EFI MAIN fuse
      Always
      Below 1 Ω
      IG2 MAIN fuse
      Always
      Below 1 Ω

  1. Inspect the EFI relay and the IG2 relay.

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      1C-1 - 1B-4
      Battery voltage not applied to terminals 1B-2 and 1B-3
      10 kΩ or higher
      Battery voltage applied to terminals 1B-2 and 1B-3
      Below 1 Ω
      1C-1 - 1B-8
      Battery voltage not applied to terminals 1B-7 and 1B-6
      10 kΩ or higher
      Battery voltage applied to terminals 1B-7 and 1B-6
      Below 1 Ω



NG
REPLACE INTEGRATION RELAY
OK


3. CHECK HARNESS AND CONNECTOR (+B AND MREL CIRCUIT)
A162269E14
  1. Check the harness and the connectors between the integration relay and the ECM.

    1. Remove the integration relay from the engine room relay block.

    2. Disconnect the ECM connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      for LHD 
      Tester Connection
      Condition
      Specified Condition
      A38-44 (MREL) - 1B-2
      Always
      Below 1 Ω
      A38-2 (+B) - 1B-4
      Always
      Below 1 Ω
      A38-1 (+B2) - 1B-4
      Always
      Below 1 Ω
      A38-44 (MREL) or 1B-2 - Body ground
      Always
      10 kΩ or higher
      A38-2 (+B) or 1B-4 - Body ground
      Always
      10 kΩ or higher
      A38-1 (+B2) or 1B-4 - Body ground
      Always
      10 kΩ or higher
      for RHD 
      Tester Connection
      Condition
      Specified Condition
      A52-44 (MREL) - 1B-2
      Always
      Below 1 Ω
      A52-2 (+B) - 1B-4
      Always
      Below 1 Ω
      A52-1 (+B2) - 1B-4
      Always
      Below 1 Ω
      A52-44 (MREL) or 1B-2 - Body ground
      Always
      10 kΩ or higher
      A52-2 (+B) or 1B-4 - Body ground
      Always
      10 kΩ or higher
      A52-1 (+B2) or 1B-4 - Body ground
      Always
      10 kΩ or higher

  1. Check the harness and connectors between the integration relay and body ground.

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      1B-3 - Body ground
      Always
      Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


4. CHECK HARNESS AND CONNECTOR (ECM - BODY GROUND)
A136305E49
  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    for LHD 
    Tester Connection
    Condition
    Specified Condition
    C45-81 (E1) - Body ground
    Always
    Below 1 Ω
    for RHD 
    Tester Connection
    Condition
    Specified Condition
    C46-81 (E1) - Body ground
    Always
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


5. INSPECT ECM (IGSW VOLTAGE)
A182331E02
  1. Disconnect the ECM connectors.

  1. Turn the engine switch on (IG).

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    for LHD 
    Tester Connection
    Switch Condition
    Specified Condition
    A38-28 (IGSW) - C45-81 (E1)
    Engine switch on (IG)
    11 to 14 V
    for RHD 
    Tester Connection
    Switch Condition
    Specified Condition
    A52-28 (IGSW) - C46-81 (E1)
    Engine switch on (IG)
    11 to 14 V



NG
Go to step 6
OK

REPLACE ECM (Click here)

6. INSPECT FUSE (IGN)
A162270E03
  1. Remove the IGN fuse from the engine room relay block.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    IGN fuse
    Always
    Below 1 Ω



NG
CHECK FOR SHORT IN ALL HARNESSES AND CONNECTORS CONNECTED TO FUSE AND REPLACE FUSE
OK


7. CHECK HARNESS AND CONNECTOR (INTEGRATION RELAY - ECM, INTEGRATION RELAY - BODY GROUND)
A162269E05
  1. Remove the integration relay from the engine room relay block.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    for LHD 
    Tester Connection
    Condition
    Specified Condition
    1B-8 - A38-28 (IGSW)
    Always
    Below 1 Ω
    1B-8 or A38-28 (IGSW) - Body ground
    Always
    10 kΩ or higher
    for RHD 
    Tester Connection
    Condition
    Specified Condition
    1B-8 - A52-28 (IGSW)
    Always
    Below 1 Ω
    1B-8 or A52-28 (IGSW) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


8. CHECK HARNESS AND CONNECTOR (MAIN BODY ECU - ENGINE ROOM RELAY BLOCK)
A182335E01
  1. Remove the integration relay from the engine room relay block.

  1. Disconnect the E2 main body ECU connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    E2-11 (IG2D) - 1B-6
    Always
    Below 1 Ω
    E2-11 (IG2D) or 1B-6 - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


9. CHECK ENTRY AND START SYSTEM (POWER SOURCE MODE DOES NOT CHANGE)
  1. Check the entry and start system (Click here).



NG
REPAIR ENTRY AND START SYSTEM
OK

REPLACE ECM (Click here)


← Turbocharger Noise (from Jan 2012)VC Output Circuit (from Jan 2012) →