ECM Power Source Circuit
Circuit diagnosis · Vehicles built from Jan 2012
DESCRIPTION
When the engine switch is turned on (IG), the battery voltage is applied to the IGSW terminal of the ECM. The output signal from the MREL terminal of the ECM causes a current to flow to the coil of the No. 1 integration relay (EFI relay), closing the contacts and supplying power to terminals +B and +B2 of the ECM.WIRING DIAGRAM


INSPECTION PROCEDURE
- NOTICE:
- Inspect the fuses for circuits related to this system before performing the following inspection procedure.
| 1. CHECK NO. 1 INTEGRATION RELAY (POWER SOURCE) |
![]() ![]() |
Remove the No. 1 integration relay from the engine room relay block.
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
Condition
Specified Condition
1C-1 - Body ground
Always
11 to 14 V
Text in Illustration *1
No. 1 Integration relay
*a
Front view of wire harness connector
(to No. 1 Integration Relay)
|
|
||||
| OK | |
| 2. INSPECT NO. 1 INTEGRATION RELAY (EFI) |
Inspect the No. 1 integration relay (EFI) (Click here).
|
|
||||
| OK | |
| 3. CHECK HARNESS AND CONNECTOR (NO. 1 INTEGRATION RELAY - ECM, BODY GROUND) |
Check the harness and connectors between the No. 1 integration relay and ECM.
Remove the No. 1 integration relay from the engine room relay block.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
for RHD Tester Connection
Condition
Specified Condition
A52-34 (MREL) - 1B-2
Always
Below 1 Ω
A52-3 (+B) - 1B-4
Always
Below 1 Ω
A52-2 (+B2) - 1B-4
Always
Below 1 Ω
A52-34 (MREL) or 1B-2 - Body ground
Always
10 kΩ or higher
A52-3 (+B) or 1B-4 - Body ground
Always
10 kΩ or higher
A52-2 (+B2) or 1B-4 - Body ground
Always
10 kΩ or higher
for LHD Tester Connection
Condition
Specified Condition
A38-34 (MREL) - 1B-2
Always
Below 1 Ω
A38-3 (+B) - 1B-4
Always
Below 1 Ω
A38-2 (+B2) - 1B-4
Always
Below 1 Ω
A38-34 (MREL) or 1B-2 - Body ground
Always
10 kΩ or higher
A38-3 (+B) or 1B-4 - Body ground
Always
10 kΩ or higher
A38-2 (+B2) or 1B-4 - Body ground
Always
10 kΩ or higher
Check the harness and connectors between the No. 1 integration relay and body ground.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
1B-3 - Body ground
Always
Below 1 Ω
|
|
||||
| OK | |
| 4. CHECK HARNESS AND CONNECTOR (ECM - BODY GROUND) |
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
for RHD Tester Connection
Condition
Specified Condition
C46-81 (E1) - Body ground
Always
Below 1 Ω
for LHD Tester Connection
Condition
Specified Condition
C45-81 (E1) - Body ground
Always
Below 1 Ω
|
|
||||
| OK | |
| 5. INSPECT ECM (IGSW VOLTAGE) |
![]() ![]() |
Disconnect the ECM connectors.
Turn the engine switch on (IG).
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
for RHD Tester Connection
Switch Condition
Specified Condition
A52-28 (IGSW) - C46-81 (E1)
Engine switch on (IG)
11 to 14 V
for LHD Tester Connection
Switch Condition
Specified Condition
A38-28 (IGSW) - C45-81 (E1)
Engine switch on (IG)
11 to 14 V
Text in Illustration *A
for RHD
*B
for LHD
*a
Front view of wire harness connector
(to ECM)
|
|
||||
| OK | ||
| ||
| 6. INSPECT NO. 1 INTEGRATION RELAY (IG2) |
Inspect the No. 1 integration relay (IG2) (Click here).
|
|
||||
| OK | |
| 7. CHECK HARNESS AND CONNECTOR (NO. 1 INTEGRATION RELAY - ECM) |
Remove the No. 1 integration relay from the engine room relay block.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
for RHD Tester Connection
Condition
Specified Condition
1B-8 - A52-28 (IGSW)
Always
Below 1 Ω
1B-8 or A52-28 (IGSW) - Body ground
Always
10 kΩ or higher
for LHD Tester Connection
Condition
Specified Condition
1B-8 - A38-28 (IGSW)
Always
Below 1 Ω
1B-8 or A38-28 (IGSW) - Body ground
Always
10 kΩ or higher
- Result:
Result
Proceed to
Out of normal range
A
Within normal range
B
|
|
||||
| A | ||
| ||
| 8. CHECK HARNESS AND CONNECTOR (NO. 1 INTEGRATION RELAY - MAIN BODY ECU, BODY GROUND) |
Remove the No. 1 integration relay from the engine room relay block.
Disconnect the Main body ECU connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
1B-6 - E2-11 (IG2D)
Always
Below 1 Ω
1B-7 - Body ground
Always
Below 1 Ω
E2-11 (IG2D) - Body ground
Always
10 kΩ or higher
|
|
||||
| OK | ||
| ||