Home › Vehicle Exterior › WINDOW / GLASS › POWER WINDOW CONTROL SYSTEM (for Models with Jam Protection Function on Driver Door Window Only)
Remote Up / Down Function does not Operate
Circuit diagnosis · Vehicles built Sep 2011 – Dec 2011
Versions by build date: Sep 2011 – Dec 2011 from Jan 2012
DESCRIPTION
When the ignition switch is ON and window lock switch is off, the multiplex network master switch sends remote up/down signals to each power window regulator motor. WIRING DIAGRAM
INSPECTION PROCEDURE
1. CHECK MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY (WINDOW LOCK SWITCH)
Turn the window lock switch off and operate the switches on the multiplex network master switch. Check that the remote up/down function operates (Click here ).
OK:
Remote up/down function operates.
NG
OK
2. CHECK MANUAL UP / DOWN FUNCTION
Check that the front passenger side power window and rear power window manual up/down function operates normally.
OK:
Manual up/down function operates normally.
NG
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here )
OK
3. CHECK HARNESS AND CONNECTOR (MULTIPLEX NETWORK MASTER SWITCH - POWER WINDOW REGULATOR SWITCH)
*1: for LHD
*2: for RHD
Disconnect the I31*1 or I26*2 multiplex network master switch assembly connector.
Disconnect the I28*1 or I30*2 power window regulator switch assembly connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance:
for LHD
Tester Connection
Condition
Specified Condition
I31-16 (U) - I28-5 (SU)
Always
Below 1 Ω
I31-15 (D) - I28-2 (SD)
Always
Below 1 Ω
I31-16 (U) or I28-5 (SU) - Body ground
Always
10 kΩ or higher
I31-15 (D) or I28-2 (SD) - Body ground
Always
10 kΩ or higher
for RHD
Tester Connection
Condition
Specified Condition
I26-12 (U) - I30-5 (SU)
Always
Below 1 Ω
I26-13 (D) - I30-2 (SD)
Always
Below 1 Ω
I26-12 (U) or I30-5 (SU) - Body ground
Always
10 kΩ or higher
I26-13 (D) or I30-2 (SD) - Body ground
Always
10 kΩ or higher
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK
4. CHECK HARNESS AND CONNECTOR (MULTIPLEX NETWORK MASTER SWITCH - REAR POWER WINDOW REGULATOR SWITCH LH)
Disconnect the I31*1 or I26*2 multiplex network master switch assembly connector.
*1: for LHD
*2: for RHD
Disconnect the J23 rear power window regulator switch assembly LH connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance:
for LHD
Tester Connection
Condition
Specified Condition
I31-12 (U) - J23-5 (SU)
Always
Below 1 Ω
I31-13 (D) - J23-2 (SD)
Always
Below 1 Ω
I31-12 (U) or J23-5 (SU) - Body ground
Always
10 kΩ or higher
I31-13 (D) or J23-2 (SD) - Body ground
Always
10 kΩ or higher
for RHD
Tester Connection
Condition
Specified Condition
I26-18 (U) - J23-5 (SU)
Always
Below 1 Ω
I26-10 (D) - J23-2 (SD)
Always
Below 1 Ω
I26-18 (U) or J23-5 (SU) - Body ground
Always
10 kΩ or higher
I26-10 (D) or J23-2 (SD) - Body ground
Always
10 kΩ or higher
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK
5. CHECK HARNESS AND CONNECTOR (MULTIPLEX NETWORK MASTER SWITCH - REAR POWER WINDOW REGULATOR SWITCH RH)
Disconnect the I31*1 or I26*2 multiplex network master switch assembly connector.
*1: for LHD
*2: for RHD
Disconnect the J21 rear power window regulator switch assembly RH connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance:
for LHD
Tester Connection
Condition
Specified Condition
I31-10 (U) - J21-5 (SU)
Always
Below 1 Ω
I31-18 (D) - J21-2 (SD)
Always
Below 1 Ω
I31-10 (U) or J21-5 (SU) - Body ground
Always
10 kΩ or higher
I31-18 (D) or J21-2 (SD) - Body ground
Always
10 kΩ or higher
for RHD
Tester Connection
Condition
Specified Condition
I26-16 (U) - J21-5 (SU)
Always
Below 1 Ω
I26-15 (D) - J21-2 (SD)
Always
Below 1 Ω
I26-16 (U) or J21-5 (SU) - Body ground
Always
10 kΩ or higher
I26-15 (D) or J21-2 (SD) - Body ground
Always
10 kΩ or higher
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK
REPLACE MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY (Click here )