INSPECTION
Inspection · Vehicles built from Sep 2011
| INSPECT PURGE VSV |
![]() ![]() |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
23 to 26 Ω
1 - VSV body ground
Always
10 kΩ or higher
2 - VSV body ground
10 kΩ or higher
Check the operation of the purge VSV.
Check that air does not flow from port F when air is applied to port E.

Text in Illustration *a
Does not flow


Air
Apply battery voltage to the connector, and check the VSV operation.

- OK:
Measurement Condition
Specified Condition
Battery positive (+) → Terminal 1
Battery negative (-) → Terminal 2
Air flows from port E to port F
If the result is not as specified, replace the purge VSV.Text in Illustration 

Air