FAIL-SAFE CHART
System information · Vehicles built from Jan 2012
| MALFUNCTION DETECTION |
Operation when malfunction is detected
Content
Operation
When thermistor trouble is detected
Heater off
When overheating (175°C (347°F)) of controller is detected
Heater off
When load short current (50 A or more) is detected
Heater off
When undervoltage (4.5 V) is detected
Heater off
OFF timer (30 min.)
After preset time of timer passes, heater off
Reverse voltage protection
Protection circuit operates
Malfunction detection conditions
When an open or short in the steering wheel thermistor continues for 2 seconds or more.
When the steering heater switch momentary switch is pressed continuously for 10 seconds or more.
Malfunction display
The LED of the steering heater switch blinks at 0.3 second intervals.
Restore condition
If the normal condition is restored for 2 seconds or more, the previous operation before the malfunction occurred continues. However, regardless of if a malfunction is detected and the malfunction operation is occurring, and regardless of if the normal condition is restored and the system is operating normally, the timer will turn off the heater 30 minutes after the switch was first turned on.