B1429/29 Rear Air Foot Duct Sensor Circuit on Front Passenger Side
Diagnostic trouble codes · Vehicles built Sep 2011 – Dec 2011
Versions by build date: Sep 2011 – Dec 2011 from Jan 2012
DESCRIPTION
The air duct temperature sensor RH*1 or LH*2 (for front passenger side) detects the duct temperature and sends the appropriate signals to the air conditioning amplifier assembly.| DTC Code |
DTC Detection Condition |
Trouble Area |
| B1429/29 |
An open or short in the air duct temperature sensor RH*1 or LH*2 circuit. |
|
- HINT:
- *1: for LHD
- *2: for RHD
WIRING DIAGRAM




INSPECTION PROCEDURE
| 1. READ VALUE USING INTELLIGENT TESTER (AIR DUCT TEMPERATURE SENSOR) |
Use the Data List to check if the air duct temperature sensor RH*1 or LH*2 (for front passenger side) is functioning properly.
Air Conditioner Tester Display
Measurement Item/Range
Normal Condition
Diagnostic Note
Foot Duct Sensor (Rear P)
Min.: -12.7°C (9.14°F)
Max.: 76.55°C (169.79°F)
Actual air duct temperature sensor (for passenger side) displayed
Open in the circuit: -12.7°C (9.14°F)
Short in the circuit: 76.55°C (169.79°F)
- HINT:
- *1: for LHD
- *2: for RHD
- OK:
- The display is as specified in the normal condition.
|
|
||||
| OK | ||
| ||
| 2. CHECK AIR DUCT TEMPERATURE SENSOR |
![]() ![]() |
for LHD
Remove the air duct temperature sensor RH (Click here).
for RHD
Remove the air duct temperature sensor LH (Click here).
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
1 (+) - 2 (-)
at 10°C (50°F)
9.4 to 10.5 kΩ
at 15°C (59°F)
7.5 to 8.3 kΩ
at 20°C (68°F)
6.0 to 6.5 kΩ
at 25°C (77°F)
4.5 to 5.2 kΩ
at 30°C (86°F)
3.8 to 4.2 kΩ
at 35°C (95°F)
3.1 to 3.4 kΩ
at 40°C (104°F)
2.5 to 2.8 kΩ
at 45°C (113°F)
2.0 to 2.3 kΩ
at 50°C (122°F)
1.6 to 2.0 kΩ
at 55°C (131°F)
1.3 to 1.6 kΩ
at 60°C (140°F)
1.1 to 1.4 kΩ
- NOTICE:
- Touching the sensor even slightly may change the resistance value. Hold the connector of the sensor.
- When measuring the resistance, the sensor temperature must be the same as the ambient temperature.
- Touching the sensor even slightly may change the resistance value. Hold the connector of the sensor.
- HINT:
- As the temperature increases, the resistance decreases (see the graph).
- If the resistance value is not as specified, replace the sensor.
Result Result
Proceed to
OK
A
NG (for LHD)
B
NG (for RHD)
C
|
|
||||
|
|
||||
| A | |
| 3. CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - AIR DUCT TEMPERATURE SENSOR) |
![]() ![]() |
for LHD
Disconnect the L12 sensor connector.
Disconnect the E35 amplifier connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
E35-26 (TR4) - L12-1 (+)
Always
Below 1 Ω
E35-12 (SG-9) - L12-2 (-)
E35-26 (TR4) - Body ground
Always
10 kΩ or higher
E35-12 (SG-9) - Body ground
for RHD

Disconnect the K21 sensor connector.
Disconnect the E35 amplifier connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
E35-25 (TR3) - K21-1 (+)
Always
Below 1 Ω
E35-34 (SGND) - K21-2 (-)
E35-25 (TR3) - Body ground
Always
10 kΩ or higher
E35-34 (SGND) - Body ground
|
|
||||
| OK | ||
| ||


