B1468/68 Rear Passenger Side Room Temperature Sensor Circuit
Diagnostic trouble codes · Vehicles built from Jan 2012
Versions by build date: Sep 2011 – Dec 2011 from Jan 2012
DESCRIPTION
The rear room temperature sensor RH*1 or LH*2 (for front passenger side) is installed in the rear quarter trim board RH*1 or LH*2 to detect the rear room temperature and control the heater and air conditioner "auto" mode. The resistance of the rear room temperature sensor RH*1 or LH*2 changes in accordance with the rear room temperature for RH*1 or LH*2 seat. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.The air conditioning amplifier applies a voltage (5 V) to the rear room temperature sensor RH*1 or LH*2 and reads voltage changes as changes in the resistance of the rear room temperature sensor RH*1 or LH*2.
| DTC Code |
DTC Detection Condition |
Trouble Area |
| B1468/68 |
An open or short in the rear room temperature sensor RH*1 or LH*2 circuit. |
|
- HINT:
- *1: for LHD
- *2: for RHD
WIRING DIAGRAM




INSPECTION PROCEDURE
| 1. READ VALUE USING INTELLIGENT TESTER (AIR CONDITIONER) |
Use the Data List to check if the rear room temperature sensor RH*1 or LH*2 is functioning properly.
Air Conditioner Tester Display
Measurement Item/Range
Normal Condition
Diagnostic Note
Room Temperature Sensor (RP)
Rear room temperature sensor for RH*1 or LH*2 /
Min.: -6.5°C (20.3°F)
Max.: 57.25°C (135.05°F)
Actual rear room temperature for RH*1 or LH*2 displayed
Open in the circuit: -6.5°C (20.3°F).
Short in the circuit: 57.25°C (135.05°F).
- HINT:
- *1: for LHD
- *2: for RHD
- OK:
- The display is as specified in the normal condition.
|
|
||||
| OK | ||
| ||
| 2. INSPECT REAR ROOM TEMPERATURE SENSOR |
![]() ![]() |
for LHDRemove the rear room temperature sensor RH (Click here).
for RHDRemove the rear room temperature sensor LH (Click here).
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
1 (+) - 2 (-)
10°C (50°F)
3.00 to 3.73 kΩ
15°C (59°F)
2.45 to 2.88 kΩ
20°C (68°F)
1.95 to 2.30 kΩ
25°C (77°F)
1.60 to 1.80 kΩ
30°C (86°F)
1.28 to 1.47 kΩ
35°C (95°F)
1.00 to 1.22 kΩ
40°C (104°F)
0.80 to 1.00 kΩ
45°C (113°F)
0.65 to 0.85 kΩ
50°C (122°F)
0.50 to 0.70 kΩ
55°C (131°F)
0.44 to 0.60 kΩ
60°C (140°F)
0.36 to 0.50 kΩ
- NOTICE:
- Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
- HINT:
- As the temperature increases, the resistance decreases (see the graph).
Result Result
Proceed to
OK
A
NG (for LHD)
B
NG (for RHD)
C
|
|
||||
|
|
||||
| A | |
| 3. CHECK HARNESS AND CONNECTOR (REAR ROOM TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER) |
![]() ![]() ![]() ![]() |
for LHD
Disconnect the z56 sensor connector.
Disconnect the E35 amplifier connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
z56-2 (-)- E35-2 (SG-6)
Always
Below 1 Ω
z56-1 (+) - E35-19 (TR7)
E35-2 (SG-6) - Body ground
Always
10 kΩ or higher
E35-19 (TR7) - Body ground
for RHD
Disconnect the z55 sensor connector.
Disconnect the E35 amplifier connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
z55-2 (-) - E35-2 (SG-6)
Always
Below 1 Ω
z55-1 (+) - E35-18 (TR)
E35-2 (SG-6) - Body ground
Always
10 kΩ or higher
E35-18 (TR) - Body ground
|
|
||||
| OK | ||
| ||