Meter Illumination does not Dim at Night
Circuit diagnosis · Vehicles built Sep 2011 – Dec 2011
Versions by build date: Sep 2011 – Dec 2011 from Jan 2012
DESCRIPTION
w/ Multi-information Display:If the dimmer switch is turned to TAIL, HEAD or AUTO, the main body ECU sends a TAIL relay signal, panel light illumination signal, panel relay signal, and TAIL cancel switch off signal to the combination meter. Then the meter and accessory meter become dim.
- HINT:
- TAIL cancel switch: When the headlights are illuminated and the TAIL cancel switch is turned on, the meter does not dim.
WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. CHECK CAN COMMUNICATION SYSTEM |
Check for DTCs (Click here).
Result Result
Proceed to
CAN communication system DTC is not output
A
CAN communication system (for LHD) DTC is output
B
CAN communication system (for RHD) DTC is output
C
|
|
||||
|
|
||||
| A | |
| 2. READ VALUE USING INTELLIGENT TESTER (LIGHT CONTROL RHEOSTAT) |
Operate the intelligent tester according to the display and select Data List (Click here).
Combination Meter Tester Display
Measurement Item/Range
Normal Condition
Diagnostic Note
Tail Cancel SW*
TAIL cancel switch condition/ON or OFF
ON: TAIL cancel switch ON
OFF: TAIL cancel switch OFF
-
Rheostat value
Light control rheostat switch input/Min.: 0, Max.: 100
Light control rheostat switch is fully turned right (0) → fully turned left (100)
Unit: %
- HINT:
- *: w/ TAIL Cancel Switch
- OK:
- Light brightness can be changed within specified range by manual operation.
|
|
||||
| OK | ||
| ||
| 3. INSPECT LIGHT CONTROL RHEOSTAT |
Inspect the light control rheostat.


Remove the light control rheostat (Click here).
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
6 (TC) - 1 (E)
TAIL cancel switch off → on
10 kΩ or higher → Below 1 Ω
5 (T) - 1 (E)
Always
10 kΩ or higher
7 (TR) - 1 (E)
Light control rheostat fully turned right → fully turned left
10 kΩ or higher → Below 100 Ω
Inspect the trip switch.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
4 (A/B) - 1 (E)
TRIP switch on (Pushed)
Below 200 Ω
TRIP switch off (Not Pushed)
1 MΩ or higher
|
|
||||
| OK | |
| 4. CHECK HARNESS AND CONNECTOR (COMBINATION METER - LIGHT CONTROL RHEOSTAT) |
Disconnect the E8 meter connector.

Disconnect the E9 rheostat connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
E8-18 (ILL+) - E9-5 (T)
Always
Below 1 Ω
E8-19 (TR) - E9-7 (TR)
E8-23 (E2) - E9-1 (E)
E8-20 (TC) - E9-6 (TC)
|
|
||||
| OK | ||
| ||