Home › Vehicle Exterior › LIGHTING (EXT) › LIGHTING SYSTEM
Turn Signal Light Circuit
Circuit diagnosis · Vehicles built Sep 2011 – Dec 2011
Versions by build date: Sep 2011 – Dec 2011 from Jan 2012
DESCRIPTION
The turn signal flasher receives a turn signal switch signal from the headlight dimmer switch, and illuminates the front turn signal light, outer rear view mirror and rear combination light. WIRING DIAGRAM
INSPECTION PROCEDURE
1. CHECK TURN SIGNAL LIGHT FUNCTION
Check that the turn signal lights blink.
Result
Result
Proceed to
All turn signal lights do not blink
A
Only front turn signal light does not blink
B
Only rear combination light does not blink
C
Only side turn signal light does not blink
D
A
2. INSPECT FUSE (LH-IG, TURN-HAZ FUSE)
Remove the LH-IG fuse from the main body ECU.
Remove the TURN-HAZ fuse from the engine room junction block.
Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
Condition
Specified Condition
LH-IG fuse
Always
Below 1 Ω
TURN-HAZ fuse
NG
OK
3. CHECK HARNESS AND CONNECTOR (TURN SIGNAL FLASHER - BATTERY AND BODY GROUND)
Disconnect the E19 turn signal flasher connector.
Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection
Condition
Specified Condition
E19-1 (IG) - Body ground
Ignition switch ON
11 to 14 V
Ignition switch off
Below 1 V
E19-4 (B) - Body ground
Always
11 to 14 V
Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
Condition
Specified Condition
E19-7 (E) - Body ground
Always
Below 1 Ω
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE (Click here )
4. CHECK HARNESS AND CONNECTOR (HEADLIGHT - TURN SIGNAL FLASHER AND BODY GROUND)
Disconnect the E19 turn signal flasher connector.
for LH:
Disconnect the A1 light connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
Condition
Specified Condition
A1-6 (B) - E19-3 (LL)
Always
Below 1 Ω
A1-3 (E) - Body ground
A1-6 (B) - Body ground
Always
10 kΩ or higher
for RH:
Disconnect the A10 light connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
Condition
Specified Condition
A10-6 (B) - E19-2 (LR)
Always
Below 1 Ω
A10-3 (E) - Body ground
A10-6 (B) - Body ground
Always
10 kΩ or higher
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE (Click here )
5. CHECK VEHICLE TYPE
Check the vehicle type.
Result
Result
Proceed to
for Double Swing Out Type
A
except Double Swing Out Type
B
B
A
6. CHECK HARNESS AND CONNECTOR (REAR COMBINATION LIGHT - TURN SIGNAL FLASHER AND BODY GROUND)
Disconnect the E19 turn signal flasher connector.
for LH:
Disconnect the n1 light connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
Condition
Specified Condition
n1-1 (TRN) - E19-3 (LL)
Always
Below 1 Ω
n1-4 (E) - Body ground
n1-1 (TRN) - Body ground
Always
10 kΩ or higher
for RH:
Disconnect the Y1 light connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
Condition
Specified Condition
Y1-3 (TRN) - E19-2 (LR)
Always
Below 1 Ω
Y1-6 (E) - Body ground
Y1-3 (TRN) - Body ground
Always
10 kΩ or higher
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE (Click here )
7. CHECK HARNESS AND CONNECTOR (REAR COMBINATION LIGHT - TURN SIGNAL FLASHER AND BODY GROUND)
Disconnect the E19 turn signal flasher connector.
for LH:
Disconnect the K4 light connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
Condition
Specified Condition
K4-4 (TRN) - E19-3 (LL)
Always
Below 1 Ω
K4-3 (E) - Body ground
K4-4 (TRN) - Body ground
Always
10 kΩ or higher
for RH:
Disconnect the L3 light connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
Condition
Specified Condition
L3-4 (TRN) - E19-2 (LR)
Always
Below 1 Ω
L3-3 (E) - Body ground
L3-4 (TRN) - Body ground
Always
10 kΩ or higher
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE (Click here )
8. CHECK HARNESS AND CONNECTOR (SIDE TURN SIGNAL LIGHT - TURN SIGNAL FLASHER AND BODY GROUND)
Disconnect the E19 turn signal flasher connector.
for LH:
Disconnect the A45 light connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance:
for Double Swing Out Type:
Tester Connection
Condition
Specified Condition
A45-1 - E19-3 (LL)
Always
Below 1 Ω
A45-2 - Body ground
A45-1 - Body ground
Always
10 kΩ or higher
except Double Swing Out Type:
Tester Connection
Condition
Specified Condition
A45-2 - E19-3 (LL)
Always
Below 1 Ω
A45-1 - Body ground
A45-2 - Body ground
Always
10 kΩ or higher
for RH:
Disconnect the A47 light connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance:
for Double Swing Out Type:
Tester Connection
Condition
Specified Condition
A47-1 - E19-2 (LR)
Always
Below 1 Ω
A47-2 - Body ground
A47-1 - Body ground
Always
10 kΩ or higher
except Double Swing Out Type:
Tester Connection
Condition
Specified Condition
A47-2 - E19-2 (LR)
Always
Below 1 Ω
A47-1 - Body ground
A47-2 - Body ground
Always
10 kΩ or higher
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE (Click here )