INSPECTION
Inspection · Vehicles built from Sep 2011
| INSPECT FUEL SUPPLY PUMP |
Inspect the suction control valve.
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
1.9 to 2.3 Ω
| INSPECT FUEL TEMPERATURE SENSOR |
![]() ![]() |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
2.32 to 2.59 Ω