B1840/59 Short in Curtain Shield Squib RH 2nd Step Circuit
Diagnostic trouble codes · Vehicles built Sep 2011 – Dec 2011
Also covers:
- B1841/59 Open in Curtain Shield Squib RH 2nd Step Circuit
- B1842/59 Short to GND in Curtain Shield Squib RH 2nd Step Circuit
- B1843/59 Short to B+ in Curtain Shield Squib RH 2nd Step Circuit
Versions by build date: Sep 2011 – Dec 2011 from Jan 2012
DESCRIPTION
The curtain shield squib RH 2nd step circuit consists of the center airbag sensor and the curtain shield airbag RH.The circuit instructs the SRS to deploy when deployment conditions are met.
These DTCs are stored when a malfunction is detected in the curtain shield squib RH 2nd step circuit.
| DTC Code |
DTC Detection Condition |
Trouble Area |
| B1840/59 |
When one of the following conditions is met:
|
|
| B1841/59 |
When one of the following conditions is met:
|
|
| B1842/59 |
When one of the following conditions is met:
|
|
| B1843/59 |
When one of the following conditions is met:
|
|
WIRING DIAGRAM


INSPECTION PROCEDURE
- NOTICE:
- When disconnecting the cable from the negative (-) battery terminal while performing repairs, some systems need to be initialized after the cable is reconnected (Click here).
- HINT:
- To perform the simulation method, enter the check mode (signal check) with the intelligent tester (Click here), and then wiggle each connector of the airbag system or drive the vehicle on various type of road (Click here).
| 1. CHECK CURTAIN SHIELD AIRBAG RH (CURTAIN SHIELD SQUIB RH 2ND STEP) |
Turn the ignition switch off.

Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Disconnect the connector from the curtain shield squib RH 2nd step.
Connect the white wire side of SST (resistance: 2.1 Ω) to connector C.
- CAUTION:
- Never connect the tester to the curtain shield airbag RH (curtain shield squib RH 2nd step) for measurement, as this may lead to a serious injury due to airbag deployment.
- NOTICE:
- Do not forcibly insert SST into the terminals of the connector when connecting SST.
- Insert SST straight into the terminals of the connector.
- Do not forcibly insert SST into the terminals of the connector when connecting SST.
- SST
- 09843-18061
Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Turn the ignition switch to ON, and wait for at least 60 seconds.
Clear the DTCs (Click here).
Turn the ignition switch off.
Turn the ignition switch to ON, and wait for at least 60 seconds.
Check for DTCs (Click here).
- OK:
- DTC B1840, B1841, B1842 or B1843 is not output.
- HINT:
- Codes other than DTC B1840, B1841, B1842 and B1843 may be output at this time, but they are not related to this check.
|
|
||||
| OK | ||
| ||
| 2. CHECK CONNECTOR |
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Disconnect SST from connector C.
Check that the No. 2 floor wire connector (on the curtain shield squib RH 2nd step side) is not damaged.
- OK:
- The lock button is not disengaged, and the claw of the lock is not deformed or damaged.
|
|
||||
| OK | |
| 3. CHECK NO. 2 FLOOR WIRE (CURTAIN SHIELD AIRBAG RH 2ND STEP CIRCUIT) |
Disconnect the connectors from the center airbag sensor.

Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
Switch Condition
Specified Condition
L20-1 (CR2+) - Body ground
Ignition switch ON
Below 1 V
L20-2 (CR2-) - Body ground
Ignition switch ON
Below 1 V
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
L20-1 (CR2+) - L20-2 (CR2-)
Always
Below 1 Ω
Release the activation prevention mechanism built into connector B (Click here).
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
L20-1 (CR2+) - L20-2 (CR2-)
Always
1 MΩ or higher
L20-1 (CR2+) - Body ground
Always
1 MΩ or higher
L20-2 (CR2-) - Body ground
Always
1 MΩ or higher
|
|
||||
| OK | |
| 4. CHECK CENTER AIRBAG SENSOR |
Connect the connectors to the curtain shield squib RH 2nd step and the center airbag sensor.

Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Turn the ignition switch to ON, and wait for at least 60 seconds.
Clear the DTCs (Click here).
Turn the ignition switch off.
Turn the ignition switch to ON, and wait for at least 60 seconds.
Check for DTCs (Click here).
- OK:
- DTC B1840, B1841, B1842 or B1843 is not output.
- HINT:
- Codes other than DTC B1840, B1841, B1842 and B1843 may be output at this time, but they are not related to this check.
|
|
||||
| OK | ||
| ||