INSPECTION
Inspection · Vehicles built from Sep 2011
| INSPECT DIFFERENTIAL LOCK SHIFT ACTUATOR |
Check the free to lock switch.
Connect lines via a relay as shown in the illustration, and check that the actuator fork moves from the free to lock position.
- NOTICE:
- Make sure to perform this inspection with the actuator removed from the vehicle. If this inspection is performed with the actuator installed to the vehicle, the actuator will be damaged.
- When inspecting the actuator, make sure to operate it with the lines connected via a relay. If the lines are not connected via a relay and battery voltage is directly applied to the actuator, the actuator will be damaged.
- Make sure to perform this inspection with the actuator removed from the vehicle. If this inspection is performed with the actuator installed to the vehicle, the actuator will be damaged.
- HINT:
- When performing the operation described above, use the DEFOG relay.


After the free to lock switch is complete, check the limit switch of the shift actuator.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
5 (RLY2) - 4 (GND)
After free to lock switch is complete
Below 12.5 Ω
6 (RLY1) - 4 (GND)
After free to lock switch is complete
500 kΩ or higher
Check the lock to free switch.
Connect lines via a relay as shown in the illustration, and check that the actuator fork moves from the lock to free position.
- NOTICE:
- Make sure to perform this inspection with the actuator removed from the vehicle. If this inspection is performed with the actuator installed to the vehicle, the actuator will be damaged.
- When inspecting the actuator, make sure to operate it with the lines connected via a relay. If the lines are not connected via a relay and battery voltage is directly applied to the actuator, the actuator will be damaged.
- Make sure to perform this inspection with the actuator removed from the vehicle. If this inspection is performed with the actuator installed to the vehicle, the actuator will be damaged.
- HINT:
- When performing the operation described above, use the DEFOG relay.


After the lock to free switch is complete, check the limit switch of the shift actuator.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
5 (RLY2) - 4 (GND)
After lock to free switch is complete
500 kΩ or higher
6 (RLY1) - 4 (GND)
After lock to free switch is complete
Below 12.5 Ω