2011-2013 Land Cruiser · Service Manual Engine / Hybrid / EV System

Millimeter Wave Radar Sensor Power Source Circuit

Circuit diagnosis · Vehicles built from Jan 2012

DESCRIPTION

This circuit provides power to the millimeter wave radar sensor. The millimeter wave radar sensor emits radio waves towards an object in front and measures the distance and direction of the object by receiving the wave reflections. Based on the reflections, the sensor calculates the difference in speed between the vehicle and the object in front. This data is transmitted to the distance control ECU.

WIRING DIAGRAM

E158908E03

INSPECTION PROCEDURE

NOTICE:
When the distance control ECU is replaced with a new one, initialization must be performed (Click here).


1. CHECK HARNESS AND CONNECTOR (MILLIMETER WAVE RADAR SENSOR - DISTANCE CONTROL ECU)

  1. E158909E02
    Disconnect the A56 millimeter wave radar sensor connector.

  1. Disconnect the E108 distance control ECU connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    A56-2 (SGND) - E108-10 (SGND)
    Always
    Below 1 Ω
    A56-5 (IGB) - E108-13 (IGB)
    E108-13 (IGB) - Body ground
    Always
    10 kΩ or higher
    A56-5 (IGB) - Body ground



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


2. CHECK DISTANCE CONTROL ECU (IGB VOLTAGE)

  1. E158910E02
    Disconnect the A56 millimeter wave radar sensor connector.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    A56-5 (IGB) - A56-2 (SGND)
    Engine switch on (IG)
    11 to 14 V



NG
REPLACE DISTANCE CONTROL ECU (Click here)
OK


3. CHECK HARNESS AND CONNECTOR (MILLIMETER WAVE RADAR SENSOR - ECM AND BODY GROUND)

  1. E158911E03
    Disconnect the A56 millimeter wave radar sensor connector.

  1. Disconnect the A38*1 or A52*2 ECM connector.

    1. *1: for LHD
    2. *2: for RHD

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    for LHD 
    Tester Connection
    Condition
    Specified Condition
    A56-1 (LGND) - A38-44 (LGND)
    Always
    Below 1 Ω
    A56-1 (LGND) - Body ground
    Always
    10 kΩ or higher
    for RHD 
    Tester Connection
    Condition
    Specified Condition
    A56-1 (LGND) - A52-44 (LGND)
    Always
    Below 1 Ω
    A56-1 (LGND) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)


← Distance Control ECU Power Source Circuit (from Jan 2012)Distance Control Switch Circuit (from Jan 2012) →