Hide 19100P 1.INSTALL SPARK PLUG

a.

Using a 16 mm plug wrench, install the 8 spark plugs.

Torque:
21 N*m (214 kgf*cm, 15 ft.*lbf)


Hide 19500 2.INSTALL IGNITION COIL ASSEMBLY

a.

for Bank 2:

i.

Install the 4 ignition coils with the 4 bolts.

Torque:
10 N*m (102 kgf*cm, 7 ft.*lbf)


ii.

Connect the 4 ignition coil connectors.


iii.

Attach the 3 clamps and connect the engine wire.


iv.

Connect the water by-pass pipe with the 2 bolts.

Torque:
18 N*m (184 kgf*cm, 13 ft.*lbf)



b.

for Bank 1:

i.

Install the 4 ignition coils with the 4 bolts.

Torque:
10 N*m (102 kgf*cm, 7 ft.*lbf)


ii.

Connect the 4 ignition coil connectors.


iii.

Attach the 4 clamps and connect the engine wire.



Hide 3.INSTALL AIR CLEANER AND HOSE

a.
A456918N01
1.885,2.448 2.344,2.646 0.458,0.198 10 false (A)

Install the air cleaner and hose with the 3 bolt.

Torque:
5.0 N*m (51 kgf*cm, 44 in.*lbf)


b.

Attach the clamp and connect the mass air flow meter connector.


c.

Connect the No. 2 PCV hose and No. 1 air hose.


d.

Tighten the hose clamp so that it is within the standard.

(A):