Home › Engine / Hybrid System › 1VD-FTV (ENGINE CONTROL) › ECD SYSTEM (w/o DPF) › from 2015.08
RM2660E _51 Engine / Hybrid System _052773 1VD-FTV ENGINE CONTROL _0254984 ECD SYSTEM(w/o DPF) J

1VD-FTV ENGINE CONTROL  ECD SYSTEM(w/o DPF)  Starter Signal Circuit  


DESCRIPTION

While the engine is being cranked, current flows from terminal ST2 of the ignition switch to the park/neutral position switch and also flows to terminal STA of the ECM (STA Signal).

CAUTION / NOTICE / HINT

NOTICE:
·

Inspect the fuses of circuits related to this system before performing the following inspection procedure.



HINT:

This chart is based on the premise that the engine can crank normally. If the engine cannot crank normally, proceed to Problem Symptoms Table (See page Engine / Hybrid System>1VD-FTV (ENGINE CONTROL)>ECD SYSTEM (w/o DPF)>PROBLEM SYMPTOMS TABLE).


PROCEDURE

1.READ VALUE USING INTELLIGENT TESTER (STARTER SIGNAL)
a.

Connect the intelligent tester to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the tester on.


d.

Enter the following menus: Powertrain / Engine / Data List / Starter Signal.


e.

Read the value.

OK:
Ignition Switch Condition Starter Signal
ON OFF
START ON




OK

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE

NG

2.CHECK HARNESS AND CONNECTOR (STARTER RELAY [ST] - ECM)
2.CHECK HARNESS AND CONNECTOR (STARTER RELAY [ST] - ECM)
a.

Remove the ST relay from the engine room relay block.


b.

Disconnect the ECM connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
for LHD
Tester Connection Condition Specified Condition
ST relay terminal 2 - A38-48 (STA) Always Below 1 Ω

for RHD
Tester Connection Switch Condition Specified Condition
ST relay terminal 2 - A52-48 (STA) Always Below 1 Ω



d.

Reinstall the starter relay (ST).


e.

Reconnect the ECM connector.



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR (STARTER RELAY [ST] - ECM)