The injector driver drives the injectors at high speeds with a high-voltage DC/DC converter. The ECM constantly monitors the injector driver and stops the engine if an abnormal condition is detected.
Refer to DTC P0201 (See page Engine / Hybrid System>1VD-FTV (ENGINE CONTROL)>ECD SYSTEM (w/o DPF)>P062D).
Disconnect the EDU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C74-8 (+B) - C73-1 (GND) | Ignition switch ON | 11 to 14 V |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C76-8 (+B) - C75-1 (GND) | Ignition switch ON | 11 to 14 V |
| *a | Front view of wire harness connector
(to Injector Driver) |
| *b | for No. 1 |
| *c | for No. 2 |
Reconnect the injector driver connectors.
OK
(See pageEngine / Hybrid System>1VD-FTV (ENGINE CONTROL)>ECD SYSTEM (w/o DPF)>CHECK FOR INTERMITTENT PROBLEMS)
NG
Inspect the EDU relay (See page Engine / Hybrid System>1VD-FTV (ENGINE CONTROL)>RELAY>ON-VEHICLE INSPECTION).
OK
NG
Remove the integration relay from the engine room relay block.
Remove the EDU relay (EDU NO. 1 or EDU NO. 2).
Disconnect the ECM connector.
Disconnect the injector driver connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1S-11 - EDU NO. 1 relay (1) | Always | Below 1 Ω |
| C74-8 (+B) - EDU NO. 1 relay (5) | Always | Below 1 Ω |
| 1S-11 or EDU NO. 1 relay (1) - Body ground | Always | 10 kΩ or higher |
| C74-8 (+B) or EDU NO. 1 relay (5) - Body ground | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1P-12 - EDU NO. 2 relay (1) | Always | Below 1 Ω |
| C76-8 (+B) - EDU NO. 2 relay (5) | Always | Below 1 Ω |
| 1P-12 - EDU NO. 2 relay (1) - Body ground | Always | 10 kΩ or higher |
| C76-8 (+B) or EDU NO. 2 relay (5) - Body ground | Always | 10 kΩ or higher |
OK
NG
Remove the integration relay from the engine room relay block and junction block assembly.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A38-45 (IREL) - EDU NO. 1 relay (2) | Always | Below 1 Ω |
| A38-45 (IREL) or EDU NO. 1 relay (2) - Body ground | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A52-45 (IREL) - EDU NO. 1 relay (2) | Always | Below 1 Ω |
| A52-45 (IREL) or EDU NO. 1 relay (2) - Body ground | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A38-46 (IRL2) - EDU NO. 2 relay (2) | Always | Below 1 Ω |
| A38-46 (IRL2) or EDU NO. 2 relay (2) - Body ground | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A52-46 (IRL2) - EDU NO. 2 relay (2) | Always | Below 1 Ω |
| A52-46 (IRL2) or EDU NO. 2 relay (2) - Body ground | Always | 10 kΩ or higher |
Reconnect the ECM connector.
Reinstall the integration relay.
OK
NG