The injector driver drives the injectors at high speeds with a high-voltage DC/DC converter. The ECM constantly monitors the injector driver and stops the engine if an abnormal condition is detected.
Refer to DTC P0201 (See page Engine / Hybrid System>1VD-FTV (ENGINE CONTROL)>ECD SYSTEM (w/ DPF)>P0201).
OK
(See pageEngine / Hybrid System>1VD-FTV (ENGINE CONTROL)>ECD SYSTEM (w/ DPF)>CHECK FOR INTERMITTENT PROBLEMS)
NG
Remove the EFI MAIN and EFI MAIN 2 fuse from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| EFI MAIN fuse | Always | Below 1 Ω |
| EFI MAIN 2 fuse | Always | Below 1 Ω |
OK
NG
Inspect the EDU relay (EDU 1 or EDU 2) (See page Engine / Hybrid System>1VD-FTV (ENGINE CONTROL)>RELAY>ON-VEHICLE INSPECTION).
OK
NG
Inspect the integration relay (EFI or EFI MAIN 2) (See page Engine / Hybrid System>1VD-FTV (ENGINE CONTROL)>RELAY>ON-VEHICLE INSPECTION).
OK
NG
Remove the EDU relay (EDU 1 or EDU 2) from the engine room relay block.
Remove the EDU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| EDU 1 relay (5) - C150-3 (+B) | Always | Below 1 Ω |
| EDU 1 relay (5) or C150-3 (+B) - Body ground | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| EDU 2 relay (5) - C154-3 (+B) | Always | Below 1 Ω |
| EDU 2 relay (5) or C154-3 (+B) - Body ground | Always | 10 kΩ or higher |
OK
NG
Remove the EDU relay (EDU 1 or EDU 2) from the engine room relay block.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| EDU 1 relay (2) - A38-45 (IREL) | Always | Below 1 Ω |
| EDU 1 relay (2) or A38-45 (IREL) - Body ground | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| EDU 2 relay (2) - A38-46 (IRL2) | Always | Below 1 Ω |
| EDU 2 relay (2) or A38-46 (IRL2) - Body ground | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| EDU 1 relay (2) - A52-45 (IREL) | Always | Below 1 Ω |
| EDU 1 relay (2) or A52-45 (IREL) - Body ground | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| EDU 2 relay (2) - A52-46 (IRL2) | Always | Below 1 Ω |
| EDU 2 relay (2) or A52-46 (IRL2) - Body ground | Always | 10 kΩ or higher |
OK
NG
Remove the integration relay from the engine room relay block.
Remove the EDU relay (EDU 1 or EDU 2).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1B-4 - EDU 1 relay (1) | Always | Below 1 Ω |
| 1B-4 - EDU 1 relay (3) | Always | Below 1 Ω |
| 1B-4 or EDU 1 relay (1) - Body ground | Always | 10 kΩ or higher |
| 1B-4 or EDU 1 relay (3) - Body ground | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1A-4 - EDU 2 relay (1) | Always | Below 1 Ω |
| 1A-4 - EDU 2 relay (3) | Always | Below 1 Ω |
| 1A-4 or EDU 2 relay (1) - Body ground | Always | 10 kΩ or higher |
| 1A-4 or EDU 2 relay (3) - Body ground | Always | 10 kΩ or higher |
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1B-2 - A38-44 (MREL) | Always | Below 1 Ω |
| 1B-3 - Body ground | Always | Below 1 Ω |
| 1B-2 or A38-44 (MREL) - Body ground | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1A-2 - A38-44 (MREL) | Always | Below 1 Ω |
| 1A-3 - Body ground | Always | Below 1 Ω |
| 1A-2 or A38-44 (MREL) - Body ground | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1B-2 - A52-44 (MREL) | Always | Below 1 Ω |
| 1B-3 - Body ground | Always | Below 1 Ω |
| 1B-2 or A52-44 (MREL) - Body ground | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1A-2 - A52-44 (MREL) | Always | Below 1 Ω |
| 1A-3 - Body ground | Always | Below 1 Ω |
| 1A-2 or A52-44 (MREL) - Body ground | Always | 10 kΩ or higher |
OK
NG
Disconnect the EDU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C150-1 (GND) - Body ground | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C154-1 (GND) - Body ground | Always | Below 1 Ω |
OK
(See pageEngine / Hybrid System>1VD-FTV (ENGINE CONTROL)>ECD SYSTEM (w/ DPF)>ECM Power Source Circuit)
NG