While the engine is being cranked, current flows from terminal STAR of the certification ECU (smart key ECU assembly) to the park/neutral position switch assembly and to terminal STA of the ECM (STA signal).
Refer to DTC P0617 (See page Engine / Hybrid System>3UR-FE (ENGINE CONTROL)>SFI SYSTEM(w/o Secondary Air Injection System)>P0617).
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Check if the engine can be cranked.
| Result | Proceed to |
|---|---|
| Engine cannot be cranked | A |
| Engine can be cranked | B |
A
B
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
Enter the following menus: Powertrain / Engine and ECT / Data List / Starter Signal.
Check the value displayed on the GTS when the engine switch is turned to the START.
| Engine Switch Position | Display (Starter Signal) |
|---|---|
| Engine switch on (IG) | Close or OFF |
| Engine started | Open or ON |
OK
NG
Inspect the starter relay (ST) (See page Engine / Hybrid System>3UR-FE (STARTING)>RELAY>ON-VEHICLE INSPECTION).
OK
NG
Inspect the starter (See page Engine / Hybrid System>3UR-FE (STARTING)>STARTER>INSPECTION).
OK
NG
Remove the starter relay (ST) from the engine room relay block.
Disconnect the starter connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| ST relay (3) - D2-1 | Always | Below 1 Ω |
| ST relay (3) or D2-1 - Body ground | Always | 10 kΩ or higher |
OK
NG
Disconnect the starter assembly connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D16-1 - Body ground | Always | 11 to 14 V |
OK
NG
Remove the starter relay (ST) from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| ST relay (1) - Body ground | Always | Below 1 Ω |
OK
NG
Remove the starter relay (ST) from the engine room relay block.
Disconnect the PNP switch connector.
Disconnect the smart key ECU assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| ST relay (2) - E128-12 (STA) | Always | Below 1 Ω |
| ST relay (2) - C24-8 | Always | Below 1 Ω |
| ST relay (2) or E128-12 (STA) - Body ground | Always | 10 kΩ or higher |
| ST relay (2) - C24-8 - Body ground | Always | 10 kΩ or higher |
OK
NG
Remove the starter relay (ST) from the engine room relay block.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| ST relay (5) - Body ground | Always | 11 to 14 V |
OK
NG
Inspect the Park/Neutral Position (PNP) switch (See page Drivetrain>AE80F (AUTOMATIC TRANSMISSION / TRANSAXLE)>PARK / NEUTRAL POSITION SWITCH>INSPECTION).
OK
NG
(See pageDrivetrain>AB60F (AUTOMATIC TRANSMISSION / TRANSAXLE)>PARK / NEUTRAL POSITION SWITCH>REMOVAL)
Disconnect the smart key ECU assembly connector.
Disconnect the PNP switch connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C24-3 - E128-10 (STAR) | Always | Below 1 Ω |
| C45-48 (NSW) - E128-10 (STAR) | Always | Below 1 Ω |
| C24-3 or E128-10 (STAR) - Body ground | Always | 10 kΩ or higher |
| C45-48 (NSW) or E128-10 (STAR) - Body ground | Always | 10 kΩ or higher |
OK
NG
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
Enter the following menus: Powertrain / Engine and ECT / Data List / Starter Signal.
Check the value displayed on the GTS when the engine switch is turned to the START.
| Engine Switch Position | Display (Starter Signal) |
|---|---|
| Engine switch on (IG) | Close or OFF |
| Engine started | Open or ON |
OK
NG