Home › Engine / Hybrid System › 3UR-FE (ENGINE CONTROL) › SFI SYSTEM(w/o Secondary Air Injection System) › 2014.08–2015.08
RM2660E _51 Engine / Hybrid System _052775 3UR-FE ENGINE CONTROL _0255032 SFI SYSTEM C

3UR-FE ENGINE CONTROL  SFI SYSTEM  P0112  Intake Air Temperature Circuit Low Input  P0113  Intake Air Temperature Circuit High Input  


DESCRIPTION

A385299E01
1.875,2.25 2.24,1.719 false 0.094,0.083 1.01,0.281 0.917,0.198 10 false Fig. 1 0.104,0.375 1.021,0.573 0.917,0.198 10 false Resistance 0.115,0.688 0.542,1.031 0.427,0.344 10 false (kΩ) 1.896,1.51 2.917,1.719 1.021,0.208 10 false Acceptable 3,4.125 3.427,4.469 0.427,0.344 10 false (°C) 3,4.344 3.406,4.646 0.406,0.302 10 true (°F) 1.313,4.208 2.458,4.531 1.146,0.323 10 false Temperature

The Intake Air Temperature (IAT) sensor, mounted on the Mass Air Flow (MAF) meter, monitors the IAT. The IAT sensor has a built-in thermistor with a resistance that varies according to the temperature of the intake air. When the IAT is low, the resistance of the thermistor increases. When the temperature is high, the resistance drops. These variations in resistance are transmitted to the ECM as voltage changes (See Fig. 1).

The IAT sensor is powered by a 5 V supply from the THA terminal of the ECM, via resistor R.

Resistor R and the IAT sensor are connected in series. When the resistance value of the IAT sensor changes, according to changes in the IAT, the voltage at terminal THA also varies. Based on this signal, the ECM increases the fuel injection volume when the engine is cold to improve driveability.

HINT:

When any of DTCs P0112 and P0113 is stored, the ECM enters fail-safe mode. During fail-safe mode, the IAT is estimated to be 20°C (68°F) by the ECM. Fail-safe mode continues until a pass condition is detected.



DTC Code DTC Detection Condition Trouble Area
P0112 A short in the IAT sensor circuit for 0.5 seconds (1 trip detection logic).
·

Short in IAT sensor circuit

·

IAT sensor (built into MAF meter)

·

ECM


P0113 An open in the IAT sensor circuit for 0.5 seconds (1 trip detection logic).
·

Open in IAT sensor circuit

·

IAT sensor (built into MAF meter)

·

ECM



HINT:

When any of these DTCs are output, check the IAT by entering the following menus: Powertrain / Engine and ECT / All Data / Intake Air.

Temperature Displayed Malfunction
-40°C (-40°F) Open circuit
140°C (284°F) or higher Short circuit


MONITOR DESCRIPTION

The ECM monitors the sensor voltage and uses this value to calculate the IAT. When the sensor output voltage deviates from the normal operating range, the ECM interprets this as a malfunction in the IAT sensor and stores a DTC.

Example:

If the sensor output voltage is higher than 4.91 V for 0.5 seconds or more, the ECM determines that there is an open in the IAT sensor circuit, and stores DTC P0113. Conversely, if the output voltage is below 0.18 V for 0.5 seconds or more, the ECM determines that there is a short in the sensor circuit, and stores DTC P0112.

If the malfunction is not repaired successfully, a DTC is stored 0.5 seconds after the engine is next started.

WIRING DIAGRAM

A162760E80
0.417,1.813 0.979,2.021 0.563,0.208 10 false C50 2.021,0.615 2.396,0.823 0.375,0.208 10 false THA 2.125,1.229 2.406,1.458 0.281,0.229 10 false E2 2.448,0.615 2.688,0.823 0.24,0.208 10 false 4 2.448,1.229 2.688,1.438 0.24,0.208 10 false 5 5.25,0.615 5.49,0.823 0.24,0.208 10 false 73 6.198,0.177 6.51,0.385 0.313,0.208 10 false 5 V 5.521,0.615 5.906,0.823 0.385,0.208 10 false THA 5.521,1.229 5.948,1.438 0.427,0.208 10 false ETHA 5.969,2.26 6.396,2.469 0.427,0.208 10 false C45 5.969,2.427 6.396,2.635 0.427,0.208 10 false ECM 5.25,1.24 5.49,1.448 0.24,0.208 10 false 98 0.417,1.979 2.667,2.51 2.25,0.531 10 false IAT Sensor (Built into MAF Meter)

CAUTION / NOTICE / HINT

HINT:

Read freeze frame data using the GTS. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data from the time the malfunction occurred.


PROCEDURE

1.READ VALUE USING GTS (INTAKE AIR TEMPERATURE)
a.

Connect the GTS to the DLC3.


b.

Turn the engine switch on (IG).


c.

Turn the tester on.


d.

Enter the following menus: Powertrain / Engine and ECT / All Data / Intake Air.


e.

Read the value displayed on the tester.

Standard:

Same as actual Intake Air Temperature (IAT).


Result
Temperature Displayed Proceed to
-40°C (-40°F) A
140°C (284°F) or higher B
Same as actual IAT C

HINT:
·

If there is an open circuit, the tester indicates -40°C (-40°F).


·

If there is a short circuit, the tester indicates 140°C (284°F) or higher.





A

2.READ VALUE USING GTS (CHECK FOR OPEN IN WIRE HARNESS)

B

4.PERFORM ACTIVE TEST USING GTS (CHECK FOR SHORT IN WIRE HARNESS)

C

2.READ VALUE USING GTS (CHECK FOR OPEN IN WIRE HARNESS)
U162828E01
0.41,1.671 1.164,1.853 0.755,0.182 10 MAF Meter 2.583,1.68 2.938,1.854 0.355,0.174 10 ECM 2.448,0.984 2.780,1.144 0.332,0.161 10 THA 2.445,1.173 2.902,1.320 0.457,0.147 10 ETHA 1.505,0.652 1.840,0.814 0.335,0.162 10 C50 1.087,4.023 1.424,4.184 0.336,0.161 10 THA 1.752,4.026 1.972,4.187 0.221,0.161 10 E2 1.313,4.003 1.883,3.47 false 1.872,4.002 2.031,3.463 false 0.081,2.082 2.459,2.451 2.378,0.369 10 Front view of wire harness connector: (to MAF Meter) 1.799,1.018 1.920,1.160 0.121,0.142 10 4 1.799,1.405 1.920,1.547 0.121,0.142 10 5 0.359,3.344 0.694,3.507 0.335,0.162 10 C50

a.

Disconnect the C50 Mass Air Flow (MAF) meter connector.


b.

Connect terminals 4 (THA) and 5 (E2) of the MAF meter wire harness side connector.


c.

Connect the GTS to the DLC3.


d.

Turn the engine switch on (IG).


e.

Turn the tester on.


f.

Enter the following menus: Powertrain / Engine and ECT / All Data / Intake Air.


g.

Read the value displayed on the tester.

Standard value:

140°C (284°F) or higher




OK

CONFIRM GOOD CONNECTION TO SENSOR. IF OK, REPLACE MASS AIR FLOW METER

NG

3.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM)
3.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM)
a.

Disconnect the C50 MAF meter connector.


b.

Disconnect the C45 ECM connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
C50-4 (THA) - C45-73 (THA) Always Below 1 Ω
C50-5 (E2) - C45-98 (ETHA) Always Below 1 Ω




OK

CONFIRM GOOD CONNECTION TO ECM. IF OK, REPLACE ECM

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

4.PERFORM ACTIVE TEST USING GTS (CHECK FOR SHORT IN WIRE HARNESS)
U162911E02
1.458,0.76 1.729,0.917 0.271,0.156 10 false C50 0.49,1.688 1.219,1.885 0.729,0.198 10 false MAF Meter 2.552,1.698 2.906,1.854 0.354,0.156 10 false ECM 2.51,1.542 2.979,1.708 0.469,0.167 10 false ETHA 2.5,1.042 2.865,1.208 0.365,0.167 10 false THA

a.

Disconnect the C50 MAF meter connector.


b.

Connect the GTS to the DLC3.


c.

Turn the engine switch on (IG).


d.

Turn the tester on.


e.

Enter the following menus: Powertrain / Engine and ECT / All Data / Intake Air.


f.

Read the value displayed on the tester.

Standard value:

-40°C (-40°F)




OK

NG

5.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM)
5.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM)
a.

Disconnect the C50 MAF meter connector.


b.

Disconnect the C45 ECM connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
C50-4 (THA) or C45-73 (THA) - Body ground Always 10 kΩ or higher




OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR