Home › Engine / Hybrid System › 1GR-FE (STARTING) › STARTER › 2014.08–2015.08
RM2660E _51 Engine / Hybrid System _052800 1GR-FE STARTING _0255230 STARTER A

1GR-FE STARTING  STARTER  INSTALLATION  


PROCEDURE

Hide 11363A 1.INSTALL FLYWHEEL HOUSING SIDE COVER

Hide 28100 2.INSTALL STARTER ASSEMBLY

a.

Install the starter with the 2 bolts.

Torque:
37 N*m (377 kgf*cm, 27 ft.*lbf)


b.

Connect the starter wire with the nut.

Torque:
9.8 N*m (100 kgf*cm, 87 in.*lbf)


c.

Connect the terminal cap.


d.

Connect the starter connector.


e.

Connect the ground wire with the bolt.

Torque:
13 N*m (130 kgf*cm, 9 ft.*lbf)


Hide 28192 3.INSTALL STARTER COVER

a.

Install the starter cover with the 3 bolts.

Torque:
12 N*m (117 kgf*cm, 8 ft.*lbf)


Hide 17105 4.INSTALL EXHAUST MANIFOLD SUB-ASSEMBLY LH

Hide 5.CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

NOTICE:

When disconnecting the cable, some systems need to be initialized after the cable is reconnected (See page General>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION).