Home › Engine / Hybrid System › 3UR-FE (STARTING) › STARTER › 2014.08–2015.08
RM2660E _51 Engine / Hybrid System _052801 3UR-FE STARTING _0255233 STARTER A

3UR-FE STARTING  STARTER  REMOVAL  


PROCEDURE

Hide 1. PRECAUTION

NOTICE:

After turning the engine switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).


Hide 2.DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

NOTICE:

When disconnecting the cable, some systems need to be initialized after the cable is reconnected (See page General>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION).


Hide 17104 3.REMOVE EXHAUST MANIFOLD SUB-ASSEMBLY RH

Hide 28192 4.REMOVE STARTER COVER

a.
A175317

Remove the 3 bolts and starter cover.


Hide 28100 5.REMOVE STARTER ASSEMBLY

a.
A260965

Disconnect the starter connector.


b.

Remove the nut and disconnect the starter wire.


c.
A260966

Remove the 2 bolts and starter.


d.
A162758

Remove the flywheel housing side cover.