Home › Engine / Hybrid System › 1UR-FE (STARTING) › STARTER › from 2015.08
RM2660E _51 Engine / Hybrid System _052802 1UR-FE STARTING _0255237 STARTER A

1UR-FE STARTING  STARTER  INSTALLATION  


PROCEDURE

Hide 28100 1.INSTALL STARTER ASSEMBLY

a.

Install the flywheel housing side cover.


b.

Install the starter with the 2 bolts.

Torque:
37 N*m (377 kgf*cm, 27 ft.*lbf)


c.

Install the starter wire with the nut.

Torque:
9.8 N*m (100 kgf*cm, 87 in.*lbf)


d.

Connect the starter connector.


Hide 28192 2.INSTALL STARTER COVER

a.

Install the starter cover with the 3 bolts.

Torque:
12 N*m (117 kgf*cm, 8 ft.*lbf)


Hide 17140 3.INSTALL EXHAUST MANIFOLD SUB-ASSEMBLY RH

Hide 4.CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

NOTICE:

When disconnecting the cable, some systems need to be initialized after the cable is reconnected (See page General>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION).