AB60F AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSMISSION SYSTEM(for 3UR-FE)  P2759  Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU)  


DESCRIPTION

The amount of current flow to the solenoid is controlled by the ECM. During the lock-up operation, if the current increases, the lock-up hydraulic pressure increases.

C221407E01
4.729,2.135 5.031,1.188 5.031,1.188 5.094,1.188 true 4.969,2.323 5.125,2.688 5.125,2.688 5.188,2.688 true 5.76,2.396 5.917,2.688 5.917,2.688 5.979,2.688 true 6.031,2.594 6.917,2.813 0.885,0.219 10 false Solenoid Coil 0.135,0.688 1.385,0.906 1.25,0.219 10 false Hydraulic Pressure 2.573,3.01 3.135,3.229 0.563,0.219 10 false Current 5.24,2.615 5.771,2.833 0.531,0.219 10 false Sleeve 5.167,1.104 6.01,1.323 0.844,0.219 10 false Spool Valve

DTC Code DTC Detection Condition Trouble Area
P2759 Open or short is detected in the shift solenoid valve SLU circuit for 1 second or more while driving (1 trip detection logic).
·

Open or short in shift solenoid valve SLU circuit

·

Shift solenoid valve SLU

·

ECM



MONITOR DESCRIPTION

When an open or short in a shift solenoid valve SLU circuit is detected, the ECM determines that there is a malfunction. The ECM will illuminate the MIL and store the DTC.

WIRING DIAGRAM

C219459E08
5.739,1.181 6.140,1.370 0.400,0.190 10 SLU+ 5.739,2.398 6.140,2.587 0.400,0.190 10 SLU- 2.345,1.061 2.746,1.250 0.400,0.190 10 SLU+ 2.345,2.279 2.746,2.468 0.400,0.190 10 SLU- 5.927,3.37 6.328,3.560 0.400,0.190 10 ECM 5.926,3.199 6.327,3.389 0.400,0.190 10 C45 2.801,2.508 2.993,2.698 0.192,0.190 10 4 2.801,1.291 2.993,1.481 0.192,0.190 10 12 5.456,1.291 5.648,1.481 0.192,0.190 10 10 5.454,2.508 5.646,2.698 0.192,0.190 10 11 1.019,1.741 2.596,1.931 1.576,0.190 10 Shift Solenoid Valve SLU 0.93,3.099 2.521,3.289 1.590,0.190 10 No. 1 Transmission Wire 0.93,2.925 1.331,3.114 0.400,0.190 10 C34 0.805,1.393 0.997,1.582 0.192,0.190 10 2 0.8,2.171 0.992,2.360 0.192,0.190 10 1

PROCEDURE

1.INSPECT NO. 1 TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLU)
a.
C214326E40
1.718,1.281 1.506,1.745 false 1.811,1.071 2.066,1.745 false 1.269,1.783 1.704,1.950 0.435,0.167 10 SLU+ 0.055,0.021 0.279,0.187 0.224,0.167 10 *a 1.926,1.783 2.350,1.950 0.424,0.167 10 SLU-

Disconnect the No. 1 transmission wire connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
12 (SLU+) - 4 (SLU-) 20°C (68°F) 5.0 to 5.6 Ω
12 (SLU+) - Body ground Always 10 kΩ or higher
4 (SLU-) - Body ground Always 10 kΩ or higher


Text in Illustration
*a Component without harness connected
(No. 1 Transmission Wire)



OK

2.CHECK HARNESS AND CONNECTOR (NO. 1 TRANSMISSION WIRE - ECM)

NG

3.INSPECT SHIFT SOLENOID VALVE SLU
2.CHECK HARNESS AND CONNECTOR (NO. 1 TRANSMISSION WIRE - ECM)
a.
U165030E02
0.938,1.75 1.354,0.844 false 1.417,0.844 1.979,1.76 false 0.094,0.021 0.385,0.229 0.292,0.208 10 false *a 1.469,0.302 1.844,0.531 0.375,0.229 10 false C45 0.5,1.771 1.219,1.969 0.719,0.198 10 false 10 (SLU+) 1.635,1.76 2.313,1.958 0.677,0.198 10 false 11 (SLU-)

Disconnect the ECM connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
C45-10 (SLU+) - C45-11 (SLU-) 20°C (68°F) 5.0 to 5.6 Ω
C45-10 (SLU+) - Body ground Always 10 kΩ or higher
C45-11 (SLU-) - Body ground Always 10 kΩ or higher


Text in Illustration
*a Front view of wire harness connector
(to ECM)



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.INSPECT SHIFT SOLENOID VALVE SLU
a.

Remove the shift solenoid valve SLU.


C209928E07
0.057,0.005 0.374,0.207 0.317,0.202 10 *a 1.757,0.949 2.207,0.361 false 2.238,0.194 2.402,0.396 0.164,0.202 10 1 1.506,0.949 1.056,0.361 false 0.918,0.194 1.082,0.396 0.164,0.202 10 2 1.757,2.945 2.207,2.358 false 2.238,2.191 2.402,2.393 0.164,0.202 10 1 1.506,2.945 1.056,2.358 false 0.918,2.191 1.082,2.393 0.164,0.202 10 2 1.923,3.928 2.122,4.130 0.200,0.202 10 (-) 1.119,3.928 1.339,4.130 0.221,0.202 10 (+)

b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 5.0 to 5.6 Ω



c.

Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) with a 21 W bulb → Terminal 2

·

Battery negative (-) → Terminal 1


Valve moves and makes an operating noise



Text in Illustration
*a Component without harness connected
(Shift Solenoid Valve SLU)


OK

REPAIR OR REPLACE NO. 1 TRANSMISSION WIRE

NG