AB60F AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSMISSION SYSTEM(for 3UR-FE)  P2716  Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)  


DESCRIPTION

Refer to DTC P2714 (See page Drivetrain>AB60F (AUTOMATIC TRANSMISSION / TRANSAXLE)>AUTOMATIC TRANSMISSION SYSTEM(for 3UR-FE)>P2714).

DTC Code DTC Detection Condition Trouble Area
P2716 Open or short is detected in the shift solenoid valve SLT circuit for 1 second or more while driving (1 trip detection logic).
·

Open or short in shift solenoid valve SLT circuit

·

Shift solenoid valve SLT

·

ECM



MONITOR DESCRIPTION

When an open or short in the shift solenoid valve SLT circuit is detected, the ECM interprets this as a fault. The ECM will turn on the MIL and store the DTC.

WIRING DIAGRAM

C219459E07
5.739,1.181 6.140,1.370 0.400,0.190 10 SLT+ 5.739,2.398 6.140,2.587 0.400,0.190 10 SLT- 2.345,1.061 2.746,1.250 0.400,0.190 10 SLT+ 2.345,2.279 2.746,2.468 0.400,0.190 10 SLT- 5.953,3.37 6.353,3.560 0.400,0.190 10 ECM 5.952,3.199 6.353,3.389 0.400,0.190 10 C45 2.801,2.508 2.993,2.698 0.192,0.190 10 5 2.801,1.291 2.993,1.481 0.192,0.190 10 13 5.535,1.291 5.727,1.481 0.192,0.190 10 9 5.533,2.508 5.725,2.698 0.192,0.190 10 8 1.019,1.741 2.596,1.931 1.576,0.190 10 Shift Solenoid Valve SLT 0.93,3.099 2.521,3.289 1.590,0.190 10 No. 1 Transmission Wire 0.93,2.925 1.331,3.114 0.400,0.190 10 C34 0.805,1.393 0.997,1.582 0.192,0.190 10 2 0.8,2.171 0.992,2.360 0.192,0.190 10 1

PROCEDURE

1.INSPECT NO. 1 TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLT)
a.
C214326E38
1.571,1.306 1.371,1.745 false 1.676,1.087 1.93,1.745 false 1.134,1.783 1.498,1.950 0.363,0.167 10 SLT+ 0.055,0.021 0.279,0.187 0.224,0.167 10 *a 1.79,1.783 2.133,1.950 0.343,0.167 10 SLT-

Disconnect the No. 1 transmission wire connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
13 (SLT+) - 5 (SLT-) 20°C (68°F) 5.0 to 5.6 Ω
13 (SLT+) - Body ground Always 10 kΩ or higher
5 (SLT-) - Body ground Always 10 kΩ or higher


Text in Illustration
*a Component without harness connected
(No. 1 Transmission Wire)



OK

2.CHECK HARNESS AND CONNECTOR (NO. 1 TRANSMISSION WIRE - ECM)

NG

3.INSPECT SHIFT SOLENOID VALVE SLT
2.CHECK HARNESS AND CONNECTOR (NO. 1 TRANSMISSION WIRE - ECM)
a.
U165028E02
0.781,1.729 1.198,0.844 false 1.271,0.854 1.75,1.75 false 0.125,0.063 0.417,0.271 0.292,0.208 10 false *a 1.458,0.302 1.833,0.531 0.375,0.229 10 false C45 0.458,1.75 1.177,1.948 0.719,0.198 10 false 8 (SLT-) 1.479,1.771 2.104,1.969 0.625,0.198 10 false 9 (SLT+)

Disconnect the ECM connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
C45-9 (SLT+) - C45-8 (SLT-) 20°C (68°F) 5.0 to 5.6 Ω
C45-9 (SLT+) - Body ground Always 10 kΩ or higher
C45-8 (SLT-) - Body ground Always 10 kΩ or higher


Text in Illustration
*a Front view of wire harness connector
(to ECM)



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR