Home › Drivetrain › AB60F (AUTOMATIC TRANSMISSION / TRANSAXLE) › AUTOMATIC TRANSMISSION SYSTEM(for 3UR-FE) › 2014.08–2015.08
RM2660E _52 Drivetrain _052805 AB60F AUTOMATIC TRANSMISSION / TRANSAXLE _0255271 AUTOMATIC TRANSMISSION SYSTEM(for 3UR-FE) C

AB60F AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSMISSION SYSTEM(for 3UR-FE)  P0748  Pressure Control Solenoid "A" Electrical (Shift Solenoid Valve SL1)  


DESCRIPTION

Shifting from 1st to 5th is performed in combination with the ON and OFF operation of shift solenoid valves SL1, SL2, S1, S2, S3, S4 and SR, which are controlled by the ECM. If an open or short circuit occurs in the shift solenoid valves, the ECM controls the remaining normal shift solenoid valves to allow the vehicle to be operated safely (See page Drivetrain>AB60F (AUTOMATIC TRANSMISSION / TRANSAXLE)>AUTOMATIC TRANSMISSION SYSTEM(for 3UR-FE)>FAIL-SAFE CHART).

DTC Code DTC Detection Condition Trouble Area
P0748 The ECM checks for an open or short in the shift solenoid valve SL1 circuit while driving and shifting between 4th and 5th gear (1 trip detection logic).
Output signal duty equals 100%.
HINT:

SL1 output signal duty is less than 100% under normal conditions.


·

Open or short in shift solenoid valve SL1 circuit

·

Shift solenoid valve SL1

·

ECM



MONITOR DESCRIPTION

This DTC indicates an open or short in the shift solenoid valve SL1 circuit. The ECM commands gear shifts by turning the shift solenoid valves ON/OFF. When there is an open or short circuit in any shift solenoid valve circuit, the ECM detects the problem, illuminates the MIL and stores the DTC. Also, the ECM performs the fail-safe function and turns the other normal shift solenoid valves ON/OFF. In the case of an open or short circuit, the ECM stops sending the current to the open or short circuited solenoid.

While driving and shifting between 4th and 5th gears, if the ECM detects an open or short in the shift solenoid valve SL1 circuit, the ECM determines that there is a malfunction (See page Drivetrain>AB60F (AUTOMATIC TRANSMISSION / TRANSAXLE)>AUTOMATIC TRANSMISSION SYSTEM(for 3UR-FE)>FAIL-SAFE CHART).

WIRING DIAGRAM

C219459E05
5.739,1.181 6.140,1.370 0.400,0.190 10 SL1+ 5.739,2.398 6.140,2.587 0.400,0.190 10 SL1- 2.345,1.061 2.746,1.250 0.400,0.190 10 SL1+ 2.345,2.279 2.746,2.468 0.400,0.190 10 SL1- 5.919,3.37 6.319,3.560 0.400,0.190 10 ECM 5.918,3.199 6.318,3.389 0.400,0.190 10 C45 2.801,2.508 2.993,2.698 0.192,0.190 10 3 2.801,1.291 2.993,1.481 0.192,0.190 10 11 5.456,1.291 5.648,1.481 0.192,0.190 10 14 5.454,2.508 5.646,2.698 0.192,0.190 10 15 1.019,1.741 2.596,1.931 1.576,0.190 10 Shift Solenoid Valve SL1 0.747,3.087 2.337,3.277 1.590,0.190 10 No. 1 Transmission Wire 0.747,2.925 1.147,3.114 0.400,0.190 10 C34 0.805,1.393 0.997,1.582 0.192,0.190 10 1 0.8,2.171 0.992,2.360 0.192,0.190 10 2

CAUTION / NOTICE / HINT

HINT:

Shift solenoid valve SL1 turns ON/OFF normally when the shift lever is in D.

ECM gear shift command 1st 2nd 3rd 4th 5th 6th
Shift solenoid valve SL1 OFF OFF OFF OFF ON ON


PROCEDURE

1.INSPECT NO. 1 TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL1)
a.
C214326E32
1.866,1.306 1.667,1.745 false 1.939,1.087 2.193,1.745 false 1.43,1.783 1.793,1.950 0.363,0.167 10 SL1+ 0.055,0.021 0.279,0.187 0.224,0.167 10 *a 2.053,1.783 2.396,1.950 0.343,0.167 10 SL1-

Disconnect the No. 1 transmission wire connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
11 (SL1+) - 3 (SL1-) 20°C (68°F) 5.0 to 5.6 Ω
11 (SL1+) - Body ground Always 10 kΩ or higher
3 (SL1-) - Body ground Always 10 kΩ or higher


Text in Illustration
*a Component without harness connected
(No. 1 Transmission Wire)



OK

2.CHECK HARNESS AND CONNECTOR (NO. 1 TRANSMISSION WIRE - ECM)

NG

3.INSPECT SHIFT SOLENOID VALVE SL1
2.CHECK HARNESS AND CONNECTOR (NO. 1 TRANSMISSION WIRE - ECM)
a.
U165021E01
0.091,0.037 0.386,0.245 0.296,0.208 10 *a 1.457,0.269 1.832,0.502 0.375,0.233 10 C45 0.786,1.795 1.544,1.963 0.757,0.168 10 14 (SL1+) 1.891,1.801 2.655,1.968 0.764,0.168 10 15 (SL1-) 1.64,0.831 1.188,1.769 false 1.721,0.828 2.208,1.77 false

Disconnect the ECM connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
C45-14 (SL1+) - C45-15 (SL1-) 20°C (68°F) 5.0 to 5.6 Ω
C45-14 (SL1+) - Body ground Always 10 kΩ or higher
C45-15 (SL1-) - Body ground Always 10 kΩ or higher


Text in Illustration
*a Front view of wire harness connector
(to ECM)



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.INSPECT SHIFT SOLENOID VALVE SL1
a.

Remove the shift solenoid valve SL1.


C197715E11
0.057,0.006 0.374,0.208 0.317,0.202 10 *a 1.757,0.95 2.207,0.362 false 2.238,0.195 2.402,0.397 0.164,0.202 10 1 1.506,0.95 1.056,0.362 false 0.918,0.195 1.082,0.397 0.164,0.202 10 2 1.757,2.946 2.207,2.359 false 2.238,2.192 2.402,2.394 0.164,0.202 10 1 1.506,2.946 1.056,2.359 false 0.918,2.192 1.082,2.394 0.164,0.202 10 2 1.923,3.929 2.147,4.131 0.224,0.202 10 (+) 1.162,3.929 1.386,4.131 0.224,0.202 10 (-)

b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 5.0 to 5.6 Ω



c.

Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) with a 21 W bulb → Terminal 1

·

Battery negative (-) → Terminal 2


Valve moves and makes an operating noise



Text in Illustration
*a Component without harness connected
(Shift Solenoid Valve SL1)


OK

REPAIR OR REPLACE NO. 1 TRANSMISSION WIRE

NG