Home › Drivetrain › AB60F (AUTOMATIC TRANSMISSION / TRANSAXLE) › AUTOMATIC TRANSMISSION SYSTEM(for 3UR-FE) › 2014.08–2015.08
RM2660E _52 Drivetrain _052805 AB60F AUTOMATIC TRANSMISSION / TRANSAXLE _0255271 AUTOMATIC TRANSMISSION SYSTEM(for 3UR-FE) C

AB60F AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSMISSION SYSTEM(for 3UR-FE)  P0985  Shift Solenoid "E" Control Circuit Low (Shift Solenoid Valve SR)  P0986  Shift Solenoid "E" Control Circuit High (Shift Solenoid Valve SR)  


DESCRIPTION

Shifting from 1st to 6th is performed in combination with ON and OFF operation of shift solenoid valves SL1, SL2, S1, S2, S3, S4 and SR, which are controlled by the ECM. If an open or short circuit occurs in any of the shift solenoid valves, the ECM controls the remaining normal shift solenoid valves to allow the vehicle to be operated safely. Also, the ECM stops sending the current to the open or short circuited solenoid (See page Drivetrain>AB60F (AUTOMATIC TRANSMISSION / TRANSAXLE)>AUTOMATIC TRANSMISSION SYSTEM(for 3UR-FE)>FAIL-SAFE CHART).

DTC Code DTC Detection Condition Trouble Area
P0985 ECM detects a short in the solenoid valve SR circuit 2 times when solenoid valve SR is operated (1 trip detection logic).
·

Short in shift solenoid valve SR circuit

·

Shift solenoid valve SR

·

ECM


P0986 ECM detects an open in the solenoid valve SR circuit 2 times when solenoid valve SR is not operated (1 trip detection logic).
·

Open in shift solenoid valve SR circuit

·

Shift solenoid valve SR

·

ECM



MONITOR DESCRIPTION

These DTCs indicate an open or short in the shift solenoid valve SR circuit. When there is an open or short circuit in any shift solenoid valve circuit, the ECM detects the problem, illuminates the MIL and stores the DTC. When shift solenoid valve SR is ON, if its resistance is 8 Ω or less, the ECM determines there is a short in the shift solenoid valve SR circuit.

When shift solenoid valve SR is OFF, if its resistance is 100 kΩ or more, the ECM determines there is an open in the shift solenoid valve SR circuit (See page Drivetrain>AB60F (AUTOMATIC TRANSMISSION / TRANSAXLE)>AUTOMATIC TRANSMISSION SYSTEM(for 3UR-FE)>FAIL-SAFE CHART).

WIRING DIAGRAM

C214968E15
5.779,2.943 6.148,3.113 0.369,0.170 10 C45 5.779,3.097 6.202,3.292 0.422,0.195 10 ECM 5.638,1.203 6.007,1.373 0.369,0.170 10 SR 5.411,1.331 5.545,1.501 0.134,0.170 10 4 3.628,1.331 3.777,1.501 0.149,0.170 10 6 3.265,1.081 3.497,1.251 0.232,0.170 10 SR 1.435,2.684 1.804,2.853 0.369,0.170 10 C34 1.435,2.838 3.079,3.033 1.644,0.195 10 No. 1 Transmission Wire 1.533,1.69 3.177,1.885 1.644,0.195 10 Shift Solenoid Valve SR

CAUTION / NOTICE / HINT

HINT:

Shift solenoid valve SR is turned ON/OFF normally when the shift lever is in D.

ECM gear shift command 1st 2nd 3rd 4th 5th 6th
Shift solenoid valve SR ON ON ON ON OFF OFF


PROCEDURE

1.INSPECT NO. 1 TRANSMISSION WIRE (SHIFT SOLENOID VALVE SR)
a.
C214326E37
1.497,1.087 1.242,1.745 false 0.055,0.021 0.279,0.187 0.224,0.167 10 *a 1.113,1.783 1.368,1.950 0.255,0.167 10 SR

Disconnect the No. 1 transmission wire connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
6 (SR) - Body ground 20°C (68°F) 11 to 15 Ω


Text in Illustration
*a Component without harness connected
(No. 1 Transmission Wire)



OK

2.CHECK HARNESS AND CONNECTOR (NO. 1 TRANSMISSION WIRE - ECM)

NG

3.INSPECT SHIFT SOLENOID VALVE SR
2.CHECK HARNESS AND CONNECTOR (NO. 1 TRANSMISSION WIRE - ECM)
a.
U165027E02
0.573,1.729 0.906,0.844 false 0.094,0.021 0.385,0.229 0.292,0.208 10 false *a 1.479,0.302 1.854,0.531 0.375,0.229 10 false C45 0.365,1.76 0.823,1.958 0.458,0.198 10 false 4 (SR)

Disconnect the ECM connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
C45-4 (SR) - Body ground 20°C (68°F) 11 to 15 Ω


Text in Illustration
*a Front view of wire harness connector
(to ECM)



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.INSPECT SHIFT SOLENOID VALVE SR
a.
C209929E04
0.057,0.005 0.374,0.206 0.317,0.202 10 *a 2.4,0.09 2.623,0.292 0.223,0.202 10 (+) 3.16,0.09 3.365,0.292 0.206,0.202 10 (-)

Remove the shift solenoid valve SR.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Shift solenoid valve SR connector terminal - Shift solenoid valve SR body 20°C (68°F) 11 to 15 Ω



c.

Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) → Shift solenoid valve SR connector

·

Battery negative (-) → Shift solenoid valve SR body


Valve moves and makes an operating noise



Text in Illustration
*a Component without harness connected
(Shift Solenoid Valve SR)


OK

REPAIR OR REPLACE NO. 1 TRANSMISSION WIRE

NG