Each audio system component connected to the AVC-LAN (communication bus) transfers switch signals using the audio visual communication local area network.
If a short to +B or short to ground occurs in the AVC-LAN, the audio system will not function normally because communication is not possible.
Depending on the parts that are replaced during vehicle inspection or maintenance, performing initialization, registration or calibration may be needed. Refer to Precaution for Navigation System (See page Audio / Visual / Telematics>NAVIGATION / MULTI INFO DISPLAY>NAVIGATION SYSTEM>PRECAUTION).
Remove the multi-media module receiver assembly with the connector(s) still connected (See page Audio / Visual / Telematics>AUDIO / VIDEO>RADIO RECEIVER (w/ Multi-display)>REMOVAL).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 7 (TX1+) - 8 (TX1-) | Always | 60 to 80 Ω |
| 45 (TX3+) - 46 (TX3-) | Always | 60 to 80 Ω |
OK
NG
Disconnect the F77 multi-media module receiver assembly connector.
Disconnect the F79 multi-display assembly connector.
Disconnect the F75 parking assist ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F77-45 (TX3+) - F79-7 (TX+) | Always | Below 1 Ω |
| F77-46 (TX3-) - F79-19 (TX-) | Always | Below 1 Ω |
| F77-7 (TX1+) - F75-11 (TX+) | Always | Below 1 Ω |
| F77-8 (TX1-) - F75-10 (TX- ) | Always | Below 1 Ω |
| F77-45 (TX3+) - Body ground | Always | 10 kΩ or higher |
| F77-46 (TX3-) - Body ground | Always | 10 kΩ or higher |
| F77-7 (TX1+) - Body ground | Always | 10 kΩ or higher |
| F77-8 (TX1-) - Body ground | Always | 10 kΩ or higher |
OK
NG
Disconnect and reconnect each slave unit one by one until the master unit returns to normal operation.
Check all slave units.
When disconnecting a slave unit causes the master unit to return to normal operation, this indicates that the slave unit is malfunctioning. Replace the malfunctioning slave unit.
Master unit returns to normal operation.
OK
NG