Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System) › 2014.08–2015.08
RM2660E _58 Vehicle Interior _052847 HEATING / AIR CONDITIONING _0255699 AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System) C

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System)  B1412/12  Ambient Temperature Sensor Circuit  


DESCRIPTION

The ambient temperature sensor is installed in the front part of the condenser to detect the ambient temperature and control the air conditioner "auto" mode. The sensor connected to the air conditioning amplifier assembly detects fluctuations in the ambient temperature. This data is used for controlling the room temperature. The sensor sends a signal to the air conditioning amplifier assembly. The resistance of the ambient temperature sensor changes in accordance with the ambient temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.

The air conditioning amplifier assembly applies voltage (5 V) to the ambient temperature sensor and reads voltage changes as the resistance of the ambient temperature sensor changes.

DTC Code DTC Detection Condition Trouble Area
B1412/12 An open or short in the ambient temperature sensor circuit.
·

Ambient temperature sensor

·

Harness or connector between ambient temperature sensor and air conditioning amplifier assembly

·

Air conditioning amplifier assembly



WIRING DIAGRAM

E156584E38
1.818,0.69 1.944,0.851 0.126,0.161 10 2 1.993,0.71 2.119,0.871 0.126,0.161 10 - 2.876,0.71 3.002,0.871 0.126,0.161 10 + 1.938,1.165 2.309,1.326 0.370,0.161 10 A14 1.938,1.323 4.026,1.484 2.087,0.161 10 Ambient Temperature Sensor 4.865,2.323 7.087,2.484 2.222,0.161 10 Air Conditioning Amplifier Assembly 3.023,0.69 3.149,0.851 0.126,0.161 10 1 5.066,0.692 5.247,0.853 0.182,0.161 10 10 5.346,0.784 5.695,0.945 0.349,0.161 10 TAM 5.342,1.807 5.863,1.968 0.521,0.161 10 SG-2 4.859,2.176 5.164,2.337 0.305,0.161 10 E35 5.072,1.719 5.253,1.880 0.182,0.161 10 16 0.054,0.036 1.451,0.271 1.398,0.235 12 w/ Rear Heater:

E156584E39
1.818,0.69 1.944,0.851 0.126,0.161 10 2 1.993,0.713 2.119,0.873 0.126,0.161 10 - 2.871,0.729 2.997,0.890 0.126,0.161 10 + 1.938,1.165 2.309,1.326 0.370,0.161 10 A14 1.938,1.323 4.026,1.484 2.087,0.161 10 Ambient Temperature Sensor 4.824,2.314 7.064,2.475 2.241,0.161 10 Air Conditioning Amplifier Assembly 3.023,0.69 3.149,0.851 0.126,0.161 10 1 5.165,0.692 5.346,0.853 0.182,0.161 10 5 5.346,0.784 5.695,0.945 0.349,0.161 10 TAM 5.342,1.807 5.863,1.968 0.521,0.161 10 SG-2 4.824,2.167 5.129,2.328 0.305,0.161 10 E81 5.072,1.719 5.253,1.880 0.182,0.161 10 13 0.054,0.037 1.428,0.271 1.374,0.235 12 w/o Rear Heater:

PROCEDURE

1.READ VALUE USING INTELLIGENT TESTER (AMBIENT TEMPERATURE SENSOR)
a.

Use the Data List to check if the ambient temperature sensor is functioning properly.

Air Conditioner
Tester Display Measurement Item/Range Normal Condition Diagnostic Note
Ambient Temp Sensor Ambient temperature sensor /
Min: -23.3°C (-9.94°F)
Max: 65.95°C (150.71°F)
Actual ambient temperature displayed Open in the circuit: -23.3°C (-9.94°F).
Short in the circuit: 65.95°C (150.71°F).

OK:

The display is as specified in the normal condition.




OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

2.INSPECT AMBIENT TEMPERATURE SENSOR
2.INSPECT AMBIENT TEMPERATURE SENSOR
E349494E01
1.896,1.271 2.219,1.271 2.219,1.271 2.823,2.167 false 1.375,2.521 1.208,2.271 false 0.844,2.531 1,2.292 false 0.146,0.094 2.583,0.458 2.438,0.365 10 false Component without harness connected: (Ambient Temperature Sensor) 1.063,1.167 2.188,1.375 1.125,0.208 10 false Sensor Area 0.792,2.521 0.99,2.729 0.198,0.208 10 false - 1.375,2.521 1.573,2.729 0.198,0.208 10 false + 4.51,0.417 5.635,0.625 1.125,0.208 10 false Resistance (kΩ) 5.208,3.083 6.333,3.292 1.125,0.208 10 false Temperature °C 5.99,3.292 6.354,3.51 0.365,0.219 10 false (°F) 4.292,0.74 4.573,0.958 0.281,0.219 10 false 4.0 4.281,0.927 4.563,1.146 0.281,0.219 10 false 3.5 4.281,1.135 4.563,1.354 0.281,0.219 10 false 3.0 4.281,1.365 4.563,1.583 0.281,0.219 10 false 2.5 4.281,1.583 4.563,1.802 0.281,0.219 10 false 2.0 4.281,1.823 4.563,2.042 0.281,0.219 10 false 1.5 4.281,2.042 4.563,2.26 0.281,0.219 10 false 1.0 4.292,2.292 4.573,2.51 0.281,0.219 10 false 0.5 4.281,2.5 4.563,2.719 0.281,0.219 10 false 0.0 4.542,2.604 4.76,2.771 0.219,0.167 10 false 10 4.896,2.604 5.115,2.771 0.219,0.167 10 false 20 5.375,2.604 5.594,2.771 0.219,0.167 10 false 30 5.833,2.615 6.052,2.781 0.219,0.167 10 false 40 6.302,2.615 6.521,2.781 0.219,0.167 10 false 50 6.656,2.615 6.875,2.781 0.219,0.167 10 false 60 4.552,2.76 4.771,2.927 0.219,0.167 10 false 50 4.906,2.76 5.125,2.927 0.219,0.167 10 false 68 5.385,2.76 5.604,2.927 0.219,0.167 10 false 86 5.781,2.771 6.094,2.979 0.313,0.208 10 false 104 6.26,2.76 6.573,2.969 0.313,0.208 10 false 122 6.615,2.76 6.927,2.969 0.313,0.208 10 false 140

a.

Remove the ambient temperature sensor (See page Vehicle Interior>HEATING / AIR CONDITIONING>AMBIENT TEMPERATURE SENSOR>REMOVAL).


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 (+) - 2 (-) 10°C (50°F) 3.00 to 3.73 kΩ
15°C (59°F) 2.45 to 2.88 kΩ
20°C (68°F) 1.95 to 2.30 kΩ
25°C (77°F) 1.60 to 1.80 kΩ
30°C (86°F) 1.28 to 1.47 kΩ
35°C (95°F) 1.00 to 1.22 kΩ
40°C (104°F) 0.80 to 1.00 kΩ
45°C (113°F) 0.65 to 0.85 kΩ
50°C (122°F) 0.50 to 0.70 kΩ
55°C (131°F) 0.44 to 0.60 kΩ
60°C (140°F) 0.36 to 0.50 kΩ


NOTICE:
·

Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.

·

When measuring, the sensor temperature must be the same as the ambient temperature.



HINT:

As the temperature increases, the resistance decreases (see the graph).




OK

3.CHECK HARNESS AND CONNECTOR (AMBIENT TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER)

NG

3.CHECK HARNESS AND CONNECTOR (AMBIENT TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER)
E349495E01
0.667,1.74 1.01,1.99 0.344,0.25 5.979,0.99 6.323,1.24 0.344,0.25 1.073,2.51 1.542,2.26 false 2.354,2.49 1.844,2.26 false 5.146,2.833 5.271,2.833 5.271,2.833 5.677,2.521 false 5.5,3.208 5.646,3.208 5.646,3.208 6.208,2.531 false 0.167,0.135 2.458,0.542 2.292,0.406 10 false Front view of wire harness connector: (to Ambient Temperature Sensor) 0.719,1.792 1.115,2.031 0.396,0.24 10 false A14 0.885,2.469 1.073,2.688 0.188,0.219 10 false + 2.438,2.438 2.625,2.656 0.188,0.219 10 false - 3.823,0.156 6.24,0.521 2.417,0.365 10 false Rear view of wire harness connector: (to Air Conditioning Amplifier Assembly) 6.031,1.031 6.323,1.219 0.292,0.188 10 true E35 4.76,2.729 5.115,2.927 0.354,0.198 10 true SG-2 5.135,3.125 5.49,3.323 0.354,0.198 10 true TAM

a.

w/ Rear Heater

i.

Disconnect the A14 sensor connector.


ii.

Disconnect the E35 amplifier connector.


iii.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A14 (+) -1 - E35-10 (TAM) Always Below 1 Ω
A14-2 (-) - E35-16 (SG-2)
E35-10 (TAM) - Body ground Always 10 kΩ or higher
E35-16 (SG-2) - Body ground




b.

w/o Rear Heater

E349496E01
0.604,1.292 0.969,1.552 0.365,0.26 5.302,0.771 5.667,1.031 0.365,0.26 1,2.042 1.427,1.74 false 2.219,2.052 1.771,1.75 false 4.875,2.302 5.031,2.302 5.031,2.302 5.406,1.927 false 5.604,2.542 5.729,2.542 5.729,2.542 5.792,1.99 false 0.125,0.146 2.396,0.542 2.271,0.396 10 false Front view of wire harness connector: (to Ambient Temperature Sensor) 3.906,0.198 6.177,0.594 2.271,0.396 10 false Rear view of wire harness connector: (to Air Conditioning Amplifier) 0.656,1.344 0.99,1.563 0.333,0.219 10 false A14 0.854,1.99 1.083,2.219 0.229,0.229 10 false + 2.302,1.979 2.531,2.208 0.229,0.229 10 false - 5.365,0.823 5.698,1.042 0.333,0.219 10 false E81 4.49,2.208 4.875,2.417 0.385,0.208 10 false SG-2 5.26,2.458 5.646,2.667 0.385,0.208 10 false TAM

i.

Disconnect the A14 sensor connector.


ii.

Disconnect the E81 amplifier connector.


iii.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A14-1 (+) - E81-5 (TAM) Always Below 1 Ω
A14-2 (-) - E81-13 (SG-2)
E81-5 (TAM) - Body ground Always 10 kΩ or higher
E81-13 (SG-2) - Body ground





OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR